FAAC 450 MPS Control Panel Installation Manual

Manual is about: Gate Operator and Control Panel

Summary of 450 MPS Control Panel

  • Page 1

    A u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n contents important safety information 2 technical data 4 unpacking the operator 5 the 402 compact operator 6 general characteristics 6 450 mps logic modes 6 installation instructions 9 prepare the gate 9 manual release mechanism 9 install the opera...

  • Page 2

    P a g e 2 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n both the installer and the owner and/or operator of this system need to read and understand this installation manual and the safety instructions supplied with other components of the gate system. This information should be retained by the...

  • Page 3

    P a g e 3 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n 6. It is extremely unsafe to compensate for a damaged gate by increasing hydraulic pressure. 7. Devices such as reversing edges and photobeams must be installed to provide better protection for personal property and pedestrians. Install r...

  • Page 4

    P a g e 4 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n t echnical d ata t he 402 c ompact o perator parameter 402 operator physical dimensions: weight, lb (kg) 14-1/3 (6.5) length, in. (mm) 36 (914) width ´ height, in. (mm) 3-1/2 ´ 3-1/2 (90 ´ 90) motor speed, rpm 1400 90-deg opening time, se...

  • Page 5

    P a g e 5 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n u npacking the o perator when you receive your 402 compact operator, complete the following steps. Inspect the shipping box for physical damage such as leaking oil or a torn carton. Then inspect the operator after you remove it from the b...

  • Page 6

    T he 402 c ompact o perator g eneral c haracteristics the 402 compact operator is an automatic, light-duty gate operator it can accommodate a gate leaf up to 10 ft (3m) in length and up to 900 lbs (410 kg) in weight. Note: the 402 compact operators are not recommended for use with solid gates. The s...

  • Page 7

    P a g e 7 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n a (automatic) logic (450 mps) gate status open a open b stop opening reversing device(s) closing reversing device(s) warning light closed opens both leaves and closes them after pause time opens single leaf connected to motor 1 and closes...

  • Page 8

    P a g e 8 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n e (semi-automatic) logic (450 mps) gate status open a open b stop opening reversing device(s) closing reversing device(s) warning light closed opens both leaves opens single leaf connected to motor 1 no effect no effect no effect off open...

  • Page 9

    P a g e 9 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n you can now move the gate leaf slowly by hand to open or close the gate. Operating the gate leaf by hand is necessary during installation and is useful during power failures. You re-engage the hydraulic system by turning the key clockwise...

  • Page 10

    P a g e 1 0 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n 402 standard a 4-1/2 in. (114 mm) b 4-1/2 in. (114 mm) c 35-1/2 in. (902 mm) d if greater than 2 in. (50 mm), construct a recess liner. E must be less than a figure 4. An inward swinging gate, top view: important mounting dimensions fig...

  • Page 11

    P a g e 1 1 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n note: clamping the front mounting bracket at the marked location before checking the swing, as instructed below, will ensure proper location of the front mounting bracket. Bolt or weld the front mounting bracket to the marked location o...

  • Page 12

    P a g e 1 2 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n i nstalling the 450 mps c ontrol p anel locate the control panel in the most convenient position possible, considering the movement of the gate. Figure 6 shows a basic layout for a two-leaf gate with the 402 compact operator. Installing...

  • Page 13

    P a g e 1 3 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n c onnect the m ain p ower s upply warning! Turn the main power off before you make any electrical connections or set any switches inside the control panel box. Wire the main power supply to control panel terminals in block j1 (see figur...

  • Page 14

    P a g e 1 4 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n figure 9. The terminal strip wiring of the 450 mps to the u. L. Listed gate operator to the u.L. Listed control panel conduit to u.L. Listed control panel enclosure according to n.E.C. U.L.Listed cord grip junction box op. 1 op. 2 1 2 3...

  • Page 15

    P a g e 1 5 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n c onnect the o perator ( s ) to the c ontrol p anel warning! Turn the main power off before you make any electrical connections or set any switches inside the control panel box. U sing a j unction b ox connecting your operator(s) to the...

  • Page 16

    P a g e 1 6 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n o pen /h old o pen d evice : to open hold the gate open, you must use a latching switch wired to terminals 18 and 19. S top b utton : the stop button you install must have normally closed (n.C.) contacts. Multiple stop buttons must be w...

  • Page 17

    Figure 11. Wiring diagram showing loop detector p a g e 1 7 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n no = normally open, nc = normally closed, c = common, tx = transmitter, rx = receiver.

  • Page 18

    W arning l ight : connect a warning light to terminals 22 and 23 in the group labeled w.Light in terminal block j3. The terminals provide an output voltage of 30 vdc, maximum power 3 watts. This output voltage will power most 24 vdc warning lights. Note: the behavior of the warning light varies acco...

  • Page 19

    P a g e 1 9 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n l eaf d elay : you may choose to delay one leaf on closing for overlapping gate leaves. Be sure the operator on the leaf for delayed closing is connected to motor 1. On opening, the leaf connected to motor 2 is delayed 2.5 sec. Note: yo...

  • Page 20

    P a g e 2 0 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n e xploded v iew , 402 cbc.

  • Page 21

    402 p arts l ist p a g e 2 1 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n pos part no. Description qty 1 2036 galvanized nut (8mm) 1 2 7220015 rear bracket 1 3 7284005 rear bracket plate 1 4 7182075 short pin 1 5 7221115 rear fork 1 6 2037 self-locking nut (8mm) 1 7* 7109145 strain relief 1 8...

  • Page 22

    P a g e 2 2 a u g u s t , 2 0 0 2 4 0 2 i n s t a l l a t i o n p roblem : t he gate does not open completely . S olution : check the gate for mechanical obstacles that might prevent the gate from opening. If the motor stops running before the gate is completely open (or closed), you need to adjust ...

  • Page 23

    To the original purchaser only: faac international, inc., warrants, for twenty-four (24) months from the date of invoice, the gate operator systems and other related systems and equipment manufactured by faac s.P.A. And distributed by faac international, inc., to be free from defects in material and...