FAAC 624 BLD Manual - page 14
13
The 3rd level programming is only used in the case of advanced customisation of the function logics already present in the
memory.
Before making changes at this level, be sure you fully understand the nature of the steps you wish to modify
and their effect on the automated system.
To access 3rd LEVEL PROGRAMMING, press push-button F and, while holding it down, press push-button + for about 10
seconds. Use of the F, + and - keys is the same as for the other two programming levels.
9. 3rd LEVEL PROGRAMMING
3rd LEVEL PROGRAMMING 10 secs
D.
Function
Setting
0 1
If you enable this function, automatic closure occurs after pause time.
Y
= automatic closure
no
= disables
02
If you enable this function, operation is with two different inputs: OPEN for opening and
CLOSE for closing.
Y
= operation on two inputs
no
= disables
03
Activation of recognition of the levels of the OPEN and CLOSE inputs (command
maintained). That is to say, the board recognises the level (for example, with OPEN
maintained and STOP pressed, on release of the latter the automated system continues
to open). If
03
is disabled, the board commands a manoeuvre only if the input is
varied.
Y
= recognition of level
no
= recognition of the
change in status
04
Activation of DEAD MAN opening (command kept pressed). If the OPEN command is
released, operation is stopped.
Y
= enables
no
= disables
05
If you enable this function, an OPEN command during opening stops the movement.
If parameter
06
is
no
the system is ready for opening.
If parameter
06
is
Y
the system is ready for closing.
Y
= at opening stops movement
no
= disables
06
If you enable this function, an OPEN command during opening reverses movement.
If parameters
05
and
06
are no OPEN has no effect during opening.
Y
= at opening reverses
no
= disables
07
If you enable this function, an OPEN command during the pause stops operation.
If parameters
07
and
08
are no OPEN recharges pause time.
Y
= in pause stops movement
no
= disables
08
If you enable this function, an OPEN command during the pause causes closure.
If parameters
07
and
08
are no l’OPEN recharges pause time.
Y
= in pause closes
no
= disables
09
If you enable this function, an OPEN command during closure, stops operation, otherwise it
reverses movement.
Y
= stops
no
= reverses
10
DEAD MAN closing enabled (command kept pressed). If you release the CLOSE command,
operation is stopped.
Y
= enables
no
= disables
1 1
If you enable this function, a CLOSE command has priority over OPEN, otherwise OPEN
has priority over CLOSE.
Y
= enables
no
= disables
12
If you enable this function, a CLOSE command commands closure when it is released.
Until CLOSE is enabled, the unit remains in closure pre-flashing.
Y
= closes when released
no
= closes at once
13
If you enable this function, a CLOSE command during opening stops operation, otherwise
the CLOSE command commands reversing immediately or at end of opening (also see
parameter
14
)
Y
= CLOSE stops movement
no
= CLOSE reverses
14
If you enable this function, and if parameter
13
is no, the CLOSE command commands
immediate closure at end of opening cycle (memory stores CLOSE). If parameters
13
and
14
are
no
CLOSE commands immediate closure.
Y
= closes at the end of
opening
no
= immediate closure
15
If you enable this function, when the system is stopped by a STOP, a subsequent OPEN
command moves in the opposite direction. If parameter
15
is
no
t always closes.
Y
= moves in the opposite
direction
no
= always closes
16
If you enable this function, during closing, the CLOSING SAFETY DEVICES stop movement
and allow resumption of movement when disengaged, otherwise they immediately rever-
se at opening.
Y
= closes at disengagement
no
= immediate reversing
17
If you enable this function, the CLOSING SAFETY DEVICES command closure when
disengaged
(also see parameter
18
).
Y
= closure when FSW
disengaged
no
= disables
18
If you enable this function, and if parameter
17
is
Y
, the unit waits for the opening cycle
to end before executing the closing command supplied by the CLOSING SAFETY
DEVICES.
Y
= closes at the end of
opening
no
= disables
19
If you enable this function, during closing, LOOP2 stops movement and allows it to
resume at disengagement, otherwise it immediately reverses at opening.
Y
= closure at disengagement
no
= immediate reversing
20
If you enable this function, LOOP2 commands closing when it disengages (also see
parameter 21).
Y
= closes if LOOP2 is free
no
= disables
2 1
If you enable this function, and if parameter
20
is
Y
, the unit waits for the opening cycle
to end before executing the closing command supplied by LOOP2.
Y
= closes at the end of opening
no
= disables
22
If you enable this function, LOOP1 commands have priority over LOOP2 commands.
Y
= enables
no
= disables
ENGLISH