FAAC 740 Manual - Automated System 740-741

Other manuals for 740: User Manual

Summary of 740

  • Page 1

    740-741 & 740d 740-741 & 740d carta riciclata 100% per la natura for nature recycled paper 100% ist umweltfreundlich 100% altpapier para la naturaleza 100% papel reciclado papier recyclé 100% pour la nature voor de natuur 100% kringlooppapier.

  • Page 2: Warnings For The Installer

    15 1) attention! To ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to people. 2) carefully read the instructions before beginning to install the product. 3) do not leave packin...

  • Page 3: Automated System 740-741

    16 fig.01 fig.02 these instructions apply to the following models: faac 740 - 741 the 740-741 gearmotor is an electro-mechanical operator designed for moving sliding gates. The non-reversing reduction system ensures the gate is mechanically locked when the gearmotor is not operating, therefore it is...

  • Page 4

    17 3. Maximum use curve the curve makes it possible to establish maximum work time (t) according to use frequency (f). With reference to iec 34-1 stan- dard, the 740-741 gearmotor with an s3 duty, can operate at a use frequency of 30-40%. To ensure efficient operation, it is necessary to operate in ...

  • Page 5

    18 fig.10 5.4. Assembling the rack 5.4.1. Steel rack to weld (fig. 11) 1) fit the three threaded pawls on the rack element, positioning them at the bottom of the slot. In this way, the slot play will enable any future adjustments to be made. 2) manually take the leaf into its closing position. 3) la...

  • Page 6

    19 important: a) the plate must activate the limit-switch on the profiled part as shown in figure 20. B) if the wheel and the travel stop plate are too close, it may be necessary to shorten the limit-switch spring by a couple of turns. Procedure for shortening the spring: - to remove the spring, tur...

  • Page 7: Control Board 740D

    20 24v f1 f2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 pe n l ed g e w. L. Tx- fsw + limits encoder motor accessories lamp main n l f + radio fca fcc open b fsw cl stop safe open a fsw sto p + - - op en b a op en fsw op fsw cl co m op en cl ose lamp pe n encoder edge op - j1 j7 j5 j3 j6 j2 f f1 f2 j...

  • Page 8

    21 24v 1 2 3 4 5 6 7 8 9 10 11 12 edge w.L. Tx-f sw + stop + - - open b a open fsw op fsw cl 24v 1 2 3 4 5 6 7 8 9 10 11 12 edge w.L. Tx-f sw + stop + - - open b a open fsw op fsw cl 24v 1 2 3 4 5 6 7 8 9 10 11 12 edge w.L. Tx-f sw + stop + - - open b a open fsw op fsw cl 1 2 5 4 3 1 2 rx tx - + - +...

  • Page 9

    22 1 2 5 4 3 1 2 rx cl1 tx cl1 1 2 5 4 3 1 2 rx cl2 tx cl2 - + - + 24 v 1 2 3 4 5 6 7 8 9 10 11 12 edge w.L. Tx-f sw + stop + - - open b a open fsw op fsw cl 1 2 5 4 3 1 2 rx cl tx cl 1 2 5 4 3 1 2 rx op/cl tx op/cl - + - + 1 2 5 4 3 1 2 rx op tx op - + - + 24v 1 2 3 4 5 6 7 8 9 10 11 12 edge w.L. T...

  • Page 10

    23 minidec plus plus decoder rp 740d 740d 740d fig. 44 fig. 43 fig. 45 fsw op - opening safety devices contact (terminal 3): the purpose of the opening safety devices is to protect the leaf movement area during opening.During opening, in the a- ap-s-e-ep logics the safety devices reverse the movemen...

  • Page 11

    24 f + + f fail safe: if this function is activated, it enables a function test of the photocells before any gate movement. If the test fails (photocells not serviceable signalled by value on the display), the gate does not start moving. = active = disabled pre-flashing (5 s): activates the flashing...

  • Page 12

    25 display function default display function default partial opening: you can adjust the width of partial leaf opening. Time can be adjusted from to in 1-second steps. If an encoder is used, the adjustment is not determined by time but by motor revs, thus obtaining greater partial-opening precision....

  • Page 13

    26 assistance request (combined with next function): if activated, at the end of countdown (settable with the next function i.E. "cycle programming") it effects 2 sec. (in addition to the value already set with the pf function) of pre-flashing at every open pulse (job request). Can be useful for set...

  • Page 14

    27 tab. 3/a tab. 3/b tab. 3/c tab. 3/d " a" ci g o l s e s l u p s u t at s e t a ga - n e p ob - n e p op o t ss e ci v e d y t e f a s g ni n e p os e ci v e d y t e f a s g ni s o l ce ci v e d y t e f a s l c / p oe ci v e d y t e f a s e g d e d e s o l c s es ol c d n a f a el e ht s n e p o )...

  • Page 15

    28 tab. 3/e tab. 3/f tab. 3/g tab. 3/h " p e" ci g o l s e s l u p s u t at s e t a ga - n e p ob - n e p op o t ss e ci v e d y t e f a s g ni n e p os e ci v e d y t e f a s g ni s o l ce ci v e d y t e f a s l c / p oe ci v e d y t e f a s e g d e d e s o l c f a el e ht s n e p o l ai tr a p e h...

  • Page 16

    Automated system 740-741 read the instructions carefully before using the product and keep them for future consultation. General safety rules if installed and used correctly, the 740-741 automated system will ensure a high degree of safety. Some simple rules regarding behaviour will avoid any accide...

  • Page 18

    Le descrizioni e le illustrazioni del presente manuale non sono impegnative. La faac si riserva il diritto, lasciando inalterate le caratteristiche essenziali dell’apparecchiatura, di apportare in qualunque momento e senza impegnarsi ad aggiornare la presente pubblicazione, le modifiche che essa rit...