FAAC S418 Manual - page 11
11
FAAC Model S418 Swing Gate Operator
Fig. 19
Fig. 20
Fig. 21
Fig. 22
The mechanical stop is coupled to a toothed sector,
Figure 19 Ref. 2.
In the case of obstructions during movement, check
that the coupling is free. DO NOT FORCE IT.
3.6.2 Mechanical Stop at Closing
1.
Prepare the operator for manual operation, see Section 5.
5.
Tighten the securing screw once again.
2.
Manually move the leaf into its closing position.
3.
Loosen the securing screw, Figure 21 Ref. 1. The screw
does not need to be completely removed.
4.
Move the mechanical stop until it is close to the front
fitting, as indicated in Figure 22.
5. Tighten the securing screw once again.
The mechanical stop is coupled to a toothed sector,
Figure 21 Ref. 2.
In the case of obstructions during movement, check
that the coupling is free.
DO NOT FORCE IT.
•
Once all necessary electrical connections have been
made, power up the system and program the control
unit based on your individual needs (see relevant
instructions).
•
Perform a test of the automated system and of all
connected accessories, paying special attention to
safety devices.
4.
AUTOMATED SYSTEM TEST
If the automated system needs to be moved manually, due to
a power outage or operator malfunction, perform the following
steps to release the device:
1.
Switch off the power supply to the system.
2.
Slide off the protective cap, Figure 23 Ref. 1.
3.
Insert the supplied release key, Figure 23 Ref. 2, and
turn it counter-clockwise until it stops, Figure 23 Ref. 3.
The release position is indicated by an open padlock.
4.
Move the leaf manually.
5.
MANUAL OPERATION