5 User manual
The Buzz has been provided with a control valve with an inbuilt ignition for the pilot light.
The level of the flame can be adjusted accordingly.
The control panel is located at the back behind the access plate. (see fig. 1.4)
5.1 Ignition pilot light
turn the knob of the control valve in the OFF-position
Open the gas bottle.
Press the knob and turn it to the position. You will hear a click and a spark will
appear which should ignite the pilot light.
If the pilot does not light then repeat procedure
Keep pressing the knob down for about ten seconds after the ignition of the pilot
light.
Let go of the knob and check whether the pilot light remains alight.
5.2 Igniting and regulating the main burner.
Turn the knob to the left, the main burner will ignite and the level of the flame can
be continuously adjusted now.
By turning the knob to the position, the main burner will be extinguished and
the pilot light will remain alight.
5.3 Extinguishing the pilot light.
Turn the knob to the OFF position, and the pilot light will be extinguished.
Turn off the tap on the gas bottle.