Factor Electronics V-66 User And Installation Manual

Manual is about: Professional Multi-room Multi-source Audio System

Summary of V-66

  • Page 1

    V-66 professional multi-room multi-source audio system user and installation manual.

  • Page 2

    Www.Factorelectronics.Com info@factorelectronics.Com safety instructions risk of electric shock do not open important safety instructions • read and keep these instructions. • heed all warnings and follow all instructions contained within this manual. • do not use this unit near water. • clean only ...

  • Page 3

    Www.Factorelectronics.Com info@factorelectronics.Com product overview thank you for choosing the factor electronics v-66 multi-room multi-source audio system. The v-66 provides the ultimate audio control in six stereo zones (expandable to 18 stereo zones) without the need for programing. The v-66 is...

  • Page 4

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 master controller/amplifier rear panel stereo line level pre-amp outputs for every zone. Connect powered sub-woofers or high power zone amplifiers or commercial audio amplifiers 6 x 50 watt stereo amplifiers or 6 x100 watts in bridge mono mod...

  • Page 5

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 keypad features the v-66 keypads are available in white (v-66-wkp) and black (v-66-bkp). The v-66 keypad is designed to be very easy to use. Five backlit buttons access zone power on/off, volume up/down, selection of sources 1-6, zone treble,...

  • Page 6

    Www.Factorelectronics.Com info@factorelectronics.Com v-66-rc infrared remote control features the v-66-rc infrared remote control provides complete zone control through the (ir) receiver located in the center of the v-66 keypad. All keypad functions can be accessed with the v-66-rc. In addition to t...

  • Page 7

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions important: the v-66 should be situated in a well ventilated location or position. Do not block the vents on the sides or top of the chassis. Proper ventilation is required for normal operation. Do not expose the unit...

  • Page 8

    Www.Factorelectronics.Com info@factorelectronics.Com v-66-kp (keypad) installation instructions important: the v-66-kp (keypad) should be mounted in an electrical box or in-wall mud ring using a screwdriver to tighten. Do not use a power drill to tighten the keypad screws. Over tightening can damage...

  • Page 9

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 speaker installation instructions stereo mode important: the v-66 amplifiers are capable of driving 4-8 ohm speaker loads in stereo mode and 8ohm loads in bridge mono mode. Never connect more than two 8ohm speakers wired in parallel to a sing...

  • Page 10

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 speaker installation instructions bridge mode important: the v-66 amplifiers are capable of driving 8 ohm speaker loads in in bridge mono mode. Never connect more than one 8ohm speaker to a single channel in bridge mono mode. Never combine th...

  • Page 11

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions pre-amp outputs installation: using the v-66 pre-amp outputs the v-66 provides 6 x stereo unbalanced line level pre-amp outputs which correspond to the 6 x zone outputs. Pre-amp outputs can be used to connect powered...

  • Page 12

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions connecting sources installation: connecting sources to the v-66 the v-66 provides 6 x stereo unbalanced line level source inputs which can be accessed by any zone. Inputs 5 and 6 provide inputs on 3.5mm stereo jacks ...

  • Page 13

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions using the 12v triggers installation: using the v-66 12vdc trigger inputs and outputs the v-66 provides 6 x 12vdc trigger outputs which correspond to the 6 x v-66 zones. When a zone is powered on by pressing and holdi...

  • Page 14

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions expansion installation: expanding the v-66 to 18 zones the v-66 provides an 18 pin expansion cable with the v-66 kit. The v-66 can be expanded up to 18 zones using three complete v-66 kits. Connect the expansion cabl...

  • Page 15

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 provides an rs-232 serial port connection located on the back panel of the v-66 and uses a db-9 cable connection. The v-66 supports bi-directional...

  • Page 16

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 rs-232 serial commands continued. Hh: balance control status ii: source control status jj: keypad connecting status (00:disconnect 01:connected) i...

  • Page 17

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 rs-232 serial commands continued. (00:disconnect 01:connected) inquiry command structure (2) ?Xxpp'cr' xx: stands for control object code 10 : all...

  • Page 18

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 specifications & warranty rms power @ 8 ohms 25 watts x 12 rms power @ 4 ohms 50 watts x 12 rms power @ 8 ohms bridge mode 100 watts x 6 s/n ratio >85db a weighted thd frequency response 20hz - 20khz input impedance >47 k ohms input sensitivi...