Page 1
V-66 professional multi-room multi-source audio system user and installation manual.
Page 2
Www.Factorelectronics.Com info@factorelectronics.Com safety instructions risk of electric shock do not open important safety instructions • read and keep these instructions. • heed all warnings and follow all instructions contained within this manual. • do not use this unit near water. • clean only ...
Page 3
Www.Factorelectronics.Com info@factorelectronics.Com product overview thank you for choosing the factor electronics v-66 multi-room multi-source audio system. The v-66 provides the ultimate audio control in six stereo zones (expandable to 18 stereo zones) without the need for programing. The v-66 is...
Page 4
Www.Factorelectronics.Com info@factorelectronics.Com v-66 master controller/amplifier rear panel stereo line level pre-amp outputs for every zone. Connect powered sub-woofers or high power zone amplifiers or commercial audio amplifiers 6 x 50 watt stereo amplifiers or 6 x100 watts in bridge mono mod...
Page 5
Www.Factorelectronics.Com info@factorelectronics.Com v-66 keypad features the v-66 keypads are available in white (v-66-wkp) and black (v-66-bkp). The v-66 keypad is designed to be very easy to use. Five backlit buttons access zone power on/off, volume up/down, selection of sources 1-6, zone treble,...
Page 6
Www.Factorelectronics.Com info@factorelectronics.Com v-66-rc infrared remote control features the v-66-rc infrared remote control provides complete zone control through the (ir) receiver located in the center of the v-66 keypad. All keypad functions can be accessed with the v-66-rc. In addition to t...
Page 7
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions important: the v-66 should be situated in a well ventilated location or position. Do not block the vents on the sides or top of the chassis. Proper ventilation is required for normal operation. Do not expose the unit...
Page 8
Www.Factorelectronics.Com info@factorelectronics.Com v-66-kp (keypad) installation instructions important: the v-66-kp (keypad) should be mounted in an electrical box or in-wall mud ring using a screwdriver to tighten. Do not use a power drill to tighten the keypad screws. Over tightening can damage...
Page 9
Www.Factorelectronics.Com info@factorelectronics.Com v-66 speaker installation instructions stereo mode important: the v-66 amplifiers are capable of driving 4-8 ohm speaker loads in stereo mode and 8ohm loads in bridge mono mode. Never connect more than two 8ohm speakers wired in parallel to a sing...
Page 10
Www.Factorelectronics.Com info@factorelectronics.Com v-66 speaker installation instructions bridge mode important: the v-66 amplifiers are capable of driving 8 ohm speaker loads in in bridge mono mode. Never connect more than one 8ohm speaker to a single channel in bridge mono mode. Never combine th...
Page 11
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions pre-amp outputs installation: using the v-66 pre-amp outputs the v-66 provides 6 x stereo unbalanced line level pre-amp outputs which correspond to the 6 x zone outputs. Pre-amp outputs can be used to connect powered...
Page 12
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions connecting sources installation: connecting sources to the v-66 the v-66 provides 6 x stereo unbalanced line level source inputs which can be accessed by any zone. Inputs 5 and 6 provide inputs on 3.5mm stereo jacks ...
Page 13
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions using the 12v triggers installation: using the v-66 12vdc trigger inputs and outputs the v-66 provides 6 x 12vdc trigger outputs which correspond to the 6 x v-66 zones. When a zone is powered on by pressing and holdi...
Page 14
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions expansion installation: expanding the v-66 to 18 zones the v-66 provides an 18 pin expansion cable with the v-66 kit. The v-66 can be expanded up to 18 zones using three complete v-66 kits. Connect the expansion cabl...
Page 15
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 provides an rs-232 serial port connection located on the back panel of the v-66 and uses a db-9 cable connection. The v-66 supports bi-directional...
Page 16
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 rs-232 serial commands continued. Hh: balance control status ii: source control status jj: keypad connecting status (00:disconnect 01:connected) i...
Page 17
Www.Factorelectronics.Com info@factorelectronics.Com v-66 installation instructions rs-232 control installation: v-66 rs-232 serial port control the v-66 rs-232 serial commands continued. (00:disconnect 01:connected) inquiry command structure (2) ?Xxpp'cr' xx: stands for control object code 10 : all...
Page 18
Www.Factorelectronics.Com info@factorelectronics.Com v-66 specifications & warranty rms power @ 8 ohms 25 watts x 12 rms power @ 4 ohms 50 watts x 12 rms power @ 8 ohms bridge mode 100 watts x 6 s/n ratio >85db a weighted thd frequency response 20hz - 20khz input impedance >47 k ohms input sensitivi...