V-66 INSTALLATION INSTRUCTIONS RS-232 CONTROL
INSTALLATION:
V-66 RS-232 Serial Port Control
The V-66 provides an RS-232 serial port connection located on the back panel of the V-66 and uses a DB-9 cable connection. The V-66
supports bi-directional RS-232 communication with third party automation systems. All keypad and remote control operations can be
controlled via RS-232 in addition to system expansion up to 18 zones or 3 master controller units linked together using the included
18 pin expansion cable. (
Baud Rate 9600, 8, N, 1 , DB9 Connector Pin out, Tx, Rx, GND)
V66 RS-232 CONTROL
'CR':Carriage Return (0x0D)
No case capitalization/ lowercase
Control order structure Reply control order frame >xxPPuu'CR' xx: stands for control object code 10 :All Zone of Main unit 1. 20 :All Zone of Main unit 2. 30 :All Zone of Main unit 3. :Zone1 of Main unit 1. :Zone2 of Main unit 1. :Zone3 of Main unit 1. ............... PP: Stands for control action code. PR:Power control PR00:Power off PR01:Power on MU:Mute control MU00:Mute off MU01:Mute on DT:Do Not Disturb control DT00:DT control off DT01:DT control on VO:Volume control VO(00-38):Volume control TR:Treble control TR(00-14):Treble control BS:Bass control BS(00-14):Bass control BL:Balance control BL(00-20):Balance control CH:Source Channel control CH(01-06):Source control Inquiry command structure (1) ?xx'CR' xx: stands for control object code 10 : All Zone of Main unit 1. 20 : All Zone of Main unit 2. 30 : All Zone of Main unit 3. : Zone1 of Main unit 1 : Zone2 of Main unit 1 : Zone3 of Main unit 1 : Zone1 of Main unit 2 : Zone2 of Main unit 2 : Zone3 of Main unit 2 ............... Reply command: >xxaabbccddeeffgghhiijj'CR' aa: PA control status bb: Power control status ([5]:Backup Zone Power Status (only on zone) cc: Mute control status dd: DT control status ee: Volume control status ff: Treble control status gg: Bass control status