Fadini Elpro 27 Instruction manual - page 11
page 22
FOR
SWINGING GA
TE
SYSTEMS
Dip-B N°1=OFF
27
meccanica
FADINI
GB
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
Accessory
Electrical connections
LED indication of functions
RED
YELLOW
GREEN
Power supply
230V 50Hz
Red
Yellow
Green
Red
Yellow
Green
Fuse 1A
Common
63 64 65 66 60 61
(
Optional: Traffic lights
plug-in card for
230V lamps)
item
7282L
Traffic lights plug-in card (Optional - Item No. 7282L):
The power supply of this card is independent from that of the control board:
230V 50Hz with an output of 100W at 230V each lamp.
Logic of operation:
-
GREEN light= driveway OPEN
-
RED light = driveway CLOSED
-
YELLOW light = it switches on before light changes from green to red
Note: In Pedestrians mode the traffic light is always RED.
Dip-Switch A
4= ON Pre-flashing Enabled: traffic lights Red - Yellow - Green
4= OFF Pre-flashing Disabled: traffic lights Red - Green
6= ON Limit switches installed
6= OFF Limit switches linked out (functioning by time setting)
Dip-Switch B
3= ON Pre-flashing time prolonged by about 2 seconds
(yellow light up to 3 seconds)
3= OFF Standard time as factory-preset
Functioning with 2 lamps (Red and Green):
Dip-Switch A
4 = OFF
Dip-Switch A
6 = adjust setting depending on whether the limit switches are
used or not in the installation
Dip-Switch B
3 = OFF
ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - Dip Switch B n°1=OFF
Limit switches:
IMPORTANT: if no limit switches
are involved, link out terminals
30 - 31 - 32 - 33 - 34.
Limit switches ( L-sw.) must have
normally closed contacts.
L30 ON= OFF on engaging L.sw. Opening M1
L31 ON= OFF on engaging L.sw. Closing M1
L33 ON= OFF on engaging L.sw. Opening M2
L34 ON= OFF on engaging L.sw. Closing M2
30 31 32 33 34
common
M1
M2
Opening
Limit switch
Closing
Limit switch
Opening
Limit switch
Closing
Limit switch