Fadini FIBO 300 Installation Manual

Manual is about: Electro-mechanical operator for heave sliding gates and doors 1.1 kW (1.5 HP)

Summary of FIBO 300

  • Page 1

    Gb installation manual ®.

  • Page 2: Gate Operator

    2 fibo 300 instructions for the installation of the sliding gate operator pic. 1 for correct fibo 300 installation and good performance, please read the instructions outlined in this manual carefully and keep to the diagrams. Important: the entire installation must be carried out by qualified techni...

  • Page 3

    3 pic. 3 fitting the base plate - the first operation involves preparing a cable containment well near the installation, connected to the fibo 300 base plate by an appropriate conduit for electrical connections (pic. 3). - in order to fit the base plate “g” it is necessary to firstly remove the prot...

  • Page 4

    4 pic. 4 pic. 5 manual gate automation release the release operation frees the gate’s movement from the installed operator in events such as power cuts and during fibo 300 installation operations. - open the cover door using the customized key “c” (pic. 2) - use a 27 mm box spanner “m” on the m18 se...

  • Page 5

    5 pic. 10 installation of limit switch strike plates “f’ in order to stop the gate’s movement, the fibo 300 has two hermetic roller tip limit switches positioned behind the automation, one of which operates during closing and one during opening (pic. 5). The two strike plates “f” for stopping gate m...

  • Page 6

    6 fibo 300 electric power panel 1 2 3 4 5 6 7 8 9 10111213 16 17 18 19 20 21 danger l2 l3 l4 l5 l8 l9 l7 l6 8a 8a 8a open relay radio connector 28 fadini 27 26 630ma elpro10plus 1.4 microprocessor 24v output { voltage change 230v/400v on off dip-switch 1 2 3 4 on - pho t ocells. St op while opening ...

  • Page 7

    7 22 23 100 n k 630 100 n k 630 13 5 21 a 1 24 6 22 a 2 13 5 21 a 1 24 62 2 a 2 1 2 3 4 5 m 16 17 18 19 20 21 22 23 r s t three- phase electric motor 230 v - 25 w max. Flashing lamp supply voltage 230 - 400 v ± 10% three-phase high voltage 10 a - 380 v fuses power contactor "open" power contactor " ...

  • Page 8

    8 in case of failure of the panel: - make sure that the power supply to the electronic programmer is 400v ±10% - make sure that the power supply to the electric motor is 400v ±10% - check fuses - check photocells if contacts are normally closed - check all nc contacts - check that no voltage drop ha...

  • Page 9

    9 before making any connections, study the enclosed electrical diagrams carefully (pic. 11, pic. 12, pic. 13). Important: the whole electrical system must be earthed (pic. 13). - power supply, electric motor and flashing light connections are made with electric cables with a section of 1.5 mm 2 for ...

  • Page 10

    10 pic. 14 pic. 15 fibo 300 is fitted with a safety system that is activated upon opening the front cover door, through an “nc” power cut-off switch which, for automations without an installed electric panel, must be connected to the elpro 10 plus programmer, terminals 14-15 (pic. 10 and pic. 11); i...

  • Page 11: Fibo 300 Technical Data

    11 fibo 300 technical data pic. 16 fibo 300 overall dimensions electric motor power output. ..............................................................1.1 kw (1.5 hp) three-phase supply voltage................................................230/400 v frequency .......................................

  • Page 12: Fibo 300 Components

    Via mantova, 177/a - 37053 cerea (verona) italy - tel. +39 0442 330422 r.A. - fax +39 0442 331054 - e-mail: info@fadini.Net - www.Fadini.Net automatic gate manufacturers ® s.N.C. European mark certifying conformity to the essential requirements of the standards 98/37/ec • declaration of conformity •...