Fairchild T7800 Installation, Operation And Maintanance Manual

Manual is about: EXTENDED RANGE MINIATURE ELECTRO-PNEUMATIC TRANSDUCER

Summary of T7800

  • Page 1

    Fairchild t7800 standard range miniature electro-pneumatic transducer installation, operation and maintenance instructions figure 1. Model t7800 standard range transducer identification number system identification number 1 2 non-incendive (division 2) approval on fm voltage input units only. Intrin...

  • Page 2

    Specifications (continued) performance specifications accuracy (isa s51.1) + + 0.25% full scale guaranteed 0.15% full scale typical hysteresis (isa s51.1) 0.1% full scale deadband 0.02% full scale (isa s51.1) repeatability 0.1% full scale position effect no measurable effect vibration effect less th...

  • Page 3

    Installation you can mount the model t7800 on a flat surface using two 10-32 screws. For more information, see figure 2. The model t7800 ships from the factory with mounting kit 16799-1 for panel or wall mounting and mounting bracket kit 16893-1 for din rail mounting. For more information, see figur...

  • Page 4

    Installation (continued) figure 6. Tr7800 outline dimensions figure 5. Td7800 outline dimensions figure 4. Tt7800 outline dimensions 4.

  • Page 5

    Figure 8. Optional mounting kit 19254-1 (sold separately) figure 7. Din rail mounting kit 16893-1 (included with unit) 5.

  • Page 6

    Pneumatic connections clean all pipelines to remove dirt and scale before installa­ tion. Apply a minimum amount of pipe compound to the male threads of the air line only. Do not use teflon tape as a sealant. Start with the third thread back and work away from the end of the fitting to avoid contami...

  • Page 7

    Calibrations / adjustments equipment required for calibration • pneumatic supply capable of delivering up to 120 psig • current supply capable of delivering up to 30 ma • pressure gauge capable of a digital readout up to 50 psig with an accuracy of 0.1% • digital volt meter capable of a readout up t...

  • Page 8

    Calibrations / adjustments (continued) figure 10. T7800 calibration configuration 8.

  • Page 9

    Components figure 11. Exploded drawing 1 2 2 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 2 table 5. T7800 transducer components description 1 2 3 4 1 5 6 1 7 8 1 9 1 10 11 1 12 1 13 14 15 16 17 1 18 19 qty. Cover, machining screw screw gasket nozzle body assembly orifice assembly spring disk diaphragm spacer ring...

  • Page 10

    Maintenance troubleshooting table 6. Troubleshooting problem solution (check) no output • supply pressure • clogged orifice leakage • connections low or improper span adjust • zero and span adjust • low supply pressure • output leakage erratic operation • dc signal • loose wires or connections • liq...