TROUBLESHOOTING
Before asking for a technician or sending your machine in for repair, please check the troubleshooting list
below. Do not attempt to repair the machine yourself.
Problem
Possible Reason
Solution
Difficult to close cover
Gasket not positioned well
Push rod jammed by float valve
Locate the gasket well
Push the rode lightly with
hand
Difficult to open cover
Float valve fails to fall after steam
release
Pressure exist inside cooker
Press the float valve light
Open the cover after the
pressure lowers
Leakage from cover
No gasket
Food leavings attached to gasket
Gasket worn
Cover not firmly closed
Place gasket as required
Replace gasket ring
Clean gasket ring
Close the cover
Leakage from flat valve
Food leavings attached to float
valve gasket ring
Float valve gasket ring worn
Clean the float valve gasket
Replace the float valve gasket
Float valve unable to rise
Excessively little food and water in
pot
Little leakage from cover or
exhaust valve
Put food and water according
to the rule
Send it to the service agency
for inspection
Discharge from exhaust
valve does not stop
Exhaust valve not in seated
position
Pressure control fails
Slide the exhaust valve to the
sealing position
Send it to the service agency
for maintenance
Lamp not bring after power
on
Bad contact with socket
Please Inspect socket
All laps flash blue:
C1 appears on nixie blue
C2 appears on nixie blue
C5 appears on nixie blue
C6 appears on nixie blue
Sensor failure
Sensor failure
Temperature too high because
there is no water inside inner pot
Temperature is too high because
inner pot is not placed.
Send it to service
Send it to service
Add water as required
Put the inner pot properly
Rice half cooked or too hard
Too little water added
Cover closed prematurely
Add more Water
After time is up, release
steam and open cover
Rice too soft
Too much water added
Reduce water level