Falcon E3840 Installation, Servicing & User Instructions

Summary of E3840

  • Page 1

    E3840/e3840f fryers installation, servicing and user instructions important the installer must ensure that the installation of the appliance is in conformity with these instructions and national regulations in force at the time of installation. Particular attention must be paid to - bs7671 iee wirin...

  • Page 2: Important Information

    Important information warranty policy shortlist warranty does not cover :- • correcting faults caused by incorrect installation of a product. • where an engineer cannot gain access to a site or a product. • repeat commission visits. • replacement of any parts where damage has been caused by misuse. ...

  • Page 3

    1.2.2 clearances the unit requires a clearance of at least 100mm to the rear between unit and any combustible wall. A minimum vertical clearance of 750mm should be allowed between top edge of flue outlet and any overlying combustible surface. Important if fryer is to be installed with other applianc...

  • Page 4

    2.3.2 e3840 / e3840f - additional controls figure 3 – e3840 / 3840f - additional controls the following additional controls are located behind cabinet door. 1. Fryer on/off switch cuts power to appliance. 2. Filtration pump switch (f model only) energises filtration pump. 3. Temperature safety limit...

  • Page 5

    2.4 pre-commissioning check 2.4.1 checking controller operation to check operation of controls, refer to using the controller - section 6.2.1. 2.4.2 checking oil filtration pump to check operation of oil filtration pump, refer to section 7. 2.5 temperature limit thermostat the unit is equipped with ...

  • Page 6

    3.5 mains on and heat demand neons a) remove control panel by undoing fixings at top and bottom of control panel and unplug control panel. B) remove electrical connections from neon. Undo neon retention nut. C) carefully replace in reverse order. 3.6 drain valve a) ensure fry pot is empty. Refer to ...

  • Page 7

    Section 5 - critical dimensions 7 .8 10 wu set to 0.8 set to 10 minutes set to wu timer pump settings set for 230v.

  • Page 8

    Section 6 - operating instructions the fryers are of single pan type and the following units are covered by this manual. E3840 - manual control model. E3840f - manual control model with built-in filtration. Use of oils (cooking medium) as these are highly flammable when in their liquid state, cautio...

  • Page 9

    Section 7 - changing/filtering the oil warning after filtering, wait 30 seconds before removing bucket. When draining, ensure the oil has time to strain through strainer basket. Heavily unfiltered oil may overflow. Note this could cause pump to block over a period of time and is considered as misuse...

  • Page 10

    Section 8 - cleaning and maintenance recommendation personal protective equipment (ppe's) should be used when cleaning or handling medium within this appliance. Warning - never pump water through the filtration pump at any time! Warning the fryer is supplied with castors at rear and should be connec...

  • Page 11

    11 section 9 - cooking hints frying food involves many variables and the following information is a guide only. 1. Ensure frying medium is clean and free of debris. 2. When topping up with oil, ensure oil level does not exceed -min- when cold and -max- when hot. 3. Never overfill baskets with food p...

  • Page 12

    Elementel em en t elementel em en t 2 4 6 1212 1010 8 4242 to co ntrol p anel to co nt ro l p an el wiring l oom (bw50137) wi rin g l oo m (bw 50 13 7) 11211 2 11111 1 11011 0 terminal bl ock te rm in al bl oc k probepr ob e neutral terminalsne ut ra l t er mi na ls neutr al bus bar ne ut ra l b us ...

  • Page 13

    13 24v ~24 v ~ 110-240v~11 0-2 40 v~ elementel em en t elementel em en t 2 4 6 1212 1010 8 4242 deta il a det ail a probepr ob e neutral terminalsne ut ra l t er mi na ls neutr al terminals ne ut ra l t er mi na ls 5 c ore m ains inle t cable 5 c or e m ain s i nl et ca bl e ma ins terminal bl ock m...

  • Page 14

    14 n e 24 6 12 10 8 42 to element bo x 16 opera ting co nt ac to r 31 22 15 79 11 safe ty co nt ac to r 30 til t swit ch safe ty st at 29 28 13 5 l1 l2 l3 7 a2 a1 17 on/off swit ch 2a fuse 23 fa st co ntroller 98 82 99 power neon 24 95 c5 83 hea t neon 97 c6 19 81 c9 110 111 112 thermist or probe 2 ...

  • Page 15

    15 circuit diagram for e3840f n e 24 6 12 10 8 42 to element bo x 16 oper ating power swit ch 31 22 15 79 11 safe ty cont ac to r 30 til t swit ch safe ty st at 29 28 22 13 5 l1 l2 l3 7 a2 a1 17 on/off swit ch 5a fuse 21 2a fuse 23 fast co ntroller 98 82 99 power neon 24 95 c5 83 hea t neon 97 96 c6...

  • Page 16

    16.