1.2.2 Clearances
The unit requires a clearance of at least 100mm to the
rear between unit and any combustible wall.
A minimum vertical clearance of 750mm should be
allowed between top edge of flue outlet and any
overlying combustible surface.
Important
If fryer is to be installed with other appliances then the
instructions for each unit should be consulted to
determine the necessary clearance to any combustible
wall or overlying surface.
Some appliances require greater clearance distances
than others. The largest clearance will therefore
determine overall distance for a complete suite of
adjoining appliances.
1.3 VENTILATION
The appliance ventilation requirements should be in line
with national and local regulations.
For multiple installations, requirements should be added
together. Installations should be made in accordance with
local and/or national regulations applying at the time.
A competent engineer must be used for any installation
work.
1.4 ELECTRICAL SUPPLY
A cable conforming to code designation 0245 IEC 57
(eg. H07RN-F 5G4) must be used for connection to a
400V 3N~ supply incorporating a suitable isolating switch.
Phase Loading
L1: 29A, L2: 29A, L3: 29A
1.1 MODEL NUMBERS, NETT WEIGHTS
and DIMENSIONS
1.2 SITING
Each unit must be installed on a firm level floor in a
well-lit draught free position. The fryer should be installed
in a freestanding position to prevent any possibility of
sideways tipping under force. The means of restraint may
be the manner of installation, such as connection to a
battery of appliances or installing the fryer in an alcove, or
by separate means, such as adequate ties.
1.2.1 Anti-tipping Bracket
An anti-tipping mechanism is also available as an
accessory. If fitted, the brackets must be installed to
locate the fryer in the correct position relative to any walls
as detailed below. Fixing holes are provided in fryer base
to accommodate the bracket. Details of fitting can be
found in Figure 1 below. The retaining chain has a quick
release eyelet. Attach securely to fixing point and secure
bracket to floor after alignment with bracket attached to
the fryer. Adjust bracket to slide below floor bracket.
Figure 1 - Anti-tipping Bracket
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE
BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.
Please ensure that any plastic coatings are removed prior
to use. Before operation, the pan requires to be
thoroughly cleaned and dried.
Discolouration of heated parts is caused by factory
testing to ensure a satisfactory unit. It does not affect
quality or performance.
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3840 Fryer
400
800
880
66
E3840F Fryer
400
800
880
77
3