Falcon E401F Installation, Servecing And User Instructions - Important Information

Summary of E401F

  • Page 1

    E401f/e402f fryers installation, servicing and user instructions important the installer must ensure that the installation of the appliance is in conformity with these instructions and national regulations in force at the time of installation. Particular attention must be paid to - bs7671 iee wiring...

  • Page 2: Important Information

    Important information warranty policy shortlist warranty does not cover :- • correcting faults caused by incorrect installation of a product. • where an engineer cannot gain access to a site or a product. • repeat commission visits. • replacement of any parts where damage has been caused by misuse. ...

  • Page 3

    1.2.2 clearances the unit requires a clearance of at least 100mm to the rear between unit and any combustible wall. A minimum vertical clearance of 750mm should be allowed between top edge of flue outlet and any overlying combustible surface. Important if fryer is to be installed with other applianc...

  • Page 4

    Section 2 - assembly and commissioning the electrical cable must be connected in accordance with the various regulations listed on the cover of this manual. 2.1 assembly a) unpack appliance b) unpack fryer baskets and accessories. C) place element guard and baskets in pan. D) level appliance and fit...

  • Page 5

    2.5 temperature limit thermostat the unit is equipped with an additional temperature limit thermostat, independent of the main controller. In the case of operating thermostat failure, allowing oil temperature to rise above predetermined legislation safe zone (230 ⁰c), limit device will activate and ...

  • Page 6

    Section 3 - servicing and conversion before attempting any servicing, turn off the electrical supply. Take steps to ensure that these cannot be inadvertently turned on. After any maintenance task, check the appliance to ensure that it performs safely and correctly as described in section 2.5. 3.1 in...

  • Page 7

    Section 4 - spares when ordering spare parts, always quote the appliance type and serial number. This information will be found on the data plate. Section 5 - critical dimensions 7 set to 0.8 set to 10 minutes set to f timer pump settings set for 230v.

  • Page 8

    Section 6 - operating instructions the fryers are of single pan type and the following units are covered by this manual. E401f - manual control model with built-in filtration. E402f - four product key electronic control model with built-in filtration. Use of oils (cooking medium) as these are highly...

  • Page 9

    6.2.2 fryer maximum basket loading (both models) pre-blanched chilled fries– 2 x 1.5kg baskets. Frozen fries – 2 x 1.2kg baskets. 6.2.3 using the controller e401f models only - manually operated when unit has been switched on as detailed in section 6.2.1 above, fryer may be operated as follows. Oil ...

  • Page 10

    6.3 programming the e402f display descriptions louu controller is in operating mode. Actual vat temperature is more than 10° below programmed vat temperature. Redy controller is in operating mode. Actual vat temperature is within proper cooking temperature range. The vat is ready to start a cook cyc...

  • Page 11

    7.1 starting the filtration process 1. Turn unit off at on/off switch and allow oil to cool below 170°c (or if cold, heat to minimum temperature of 60°c). Open cabinet door and pull filter bucket forward. 2. Ensure bucket is clean and emptied of all oil and debris. Refer to section 8 for details of ...

  • Page 12

    4. Raise elements using tool provided (located behind unit door. Rest elements on rear support bar. 5. With drain valve open, remove any traces of debris from fry pot using a clean, damp cloth. Note: care should be taken not to damage sensors that are secured to elements. 6. Remove strainer and micr...

  • Page 13

    13 element element 24 6 8 10 12 13 42 14 5 c ore m ains inle t cable 5 c or e m ain s i nl et ca bl e ma ins terminal bl ock ma in s t er mi na l b lo ck brown bro wn black bla ck grey gre y blue blu e green/yell ow gre en/ yel low co nt ro l p an el co nt ro l p an el 4343 4343 1 3 5 1313 1414 1515...

  • Page 14

    14 2 way crimp terminal housing 94 4 way crimp terminal housing fast cttc programmable controller 93 91 92 94 91 92 93 96 95 9 way female plug housing 96 95 com. N.O. N.C. Com. N.O. N.C. J3 j4 j2 9 way female plug housing g5 fastron controller 91 92 t12 97 probe t5 t4 t1 t7 t2 t3 relay t6 95 98 99 8...

  • Page 15

    N e 13 14 24 6 12 10 8 42 to element bo x 16 opera ting co nt ac to r 32 22 15 79 11 safe ty co nt ac to r 30 til t swit ch safe ty st at 29 28 20 13 5 l1 l2 l3 7 a2 a1 17 on/off swit ch 5a fuse 21 2a fuse 23 fa st co ntroller 98 82 99 power neon 24 95 c5 83 hea t neon 97 96 c6 19 81 c9 31 pump swit...

  • Page 16

    N e 13 14 24 6 12 10 8 42 to element bo x 16 opera ting co nt ac to r 32 22 15 79 11 safe ty co nt ac to r 30 til t swit ch safe ty st at 29 28 20 13 5 l1 l2 l3 7 a2 a1 17 on/off swit ch 5a fuse 21 2a fuse 23 ct t co ntroller 24 95 c5 96 c6 19 c9 31 pump swit ch 25 91 92 39 40 to thermist or probe c...