FältCom ECII SE Manual And Installation Instructions

Manual is about: FältCom ECII SE Manual and installation instructions

Summary of ECII SE

  • Page 1

    Manual fältcom ecii se eng page 1 of 36 version: 5.2 updated: 2006-10-25 fältcom ecii se manual and installation instructions.

  • Page 2: Table of Contents

    Manual fältcom ecii se eng page 2 of 36 1 table of contents 1 table of contents ................................................................................................... 2 2 notes..................................................................................................................

  • Page 3

    Manual fältcom ecii se eng page 3 of 36 7.2.6 busy line function................................................................................................. 6 7.2.7 battery alarm receiver.......................................................................................... 6 7.2.8 simplifie...

  • Page 4: 2 Notes

    Manual fältcom ecii se eng page 4 of 36 2 notes we would like to thank you for placing your confidence in fält communications ab and are convinced about the choice of one of our security products will fulfill your expectations. In order to operate this fältcom ecii se correctly we would ask you to r...

  • Page 5

    Manual fältcom ecii se eng page 5 of 36 warranty does not include: - incorrect or careless usage - damages caused by thunderstorms or air pollution. - vandalism or damage. - normal wear fält communications ab reserves the right to determine if the product will be repaired or replaced. Warranty cease...

  • Page 6

    Manual fältcom ecii se eng page 6 of 36 3.4.1 service form.

  • Page 7

    Manual fältcom ecii se eng page 7 of 36.

  • Page 8: 4 General

    Manual fältcom ecii se eng page 8 of 36 4 general 4.1 contents of packing packing for fältcom ecii se contains following parts: art no. 2160 - fältcom ecii se complete , includes: - art no. 2156 fältcom ecii se - art no. 2138 mounting frame - art no. 2019 mounting kit ecii - art no. 2022 ecii sticke...

  • Page 9

    Manual fältcom ecii se eng page 9 of 36 responsibility for possible defects, operational disturbance, accidents etc. Caused by lack of knowledge or carelessness from the user. The same principle is valid for all not approved changes to the product. Fält communications ab reserves the right to make c...

  • Page 10

    Manual fältcom ecii se eng page 10 of 36 on the lift phone’s front plate, there are two pictograms and two single colored led (yellow and green), which is normally off. The left led becomes yellow when an alarm call is in progress and the right led becomes green when the alarm has been received by a...

  • Page 11

    Manual fältcom ecii se eng page 11 of 36 5.2.2 multiple lift phone connection several lift phones may be connected to the same telephone line. When one of the lift phones has established a connection, the other ones will not be able to use the line; a busy tone will instead be heard in the loudspeak...

  • Page 12: 6 Installation

    Manual fältcom ecii se eng page 12 of 36 5.2.3 programming and testing on the back of the lift phone, there is a keypad used for programming call numbers, function selection, and testing. All such settings are made during the installation and, normally, no subsequent changes are required. It is also...

  • Page 13

    Manual fältcom ecii se eng page 13 of 36 3. Fasten the lift phone with the 4 enclosed screws. If it will not be possible to access the lift phone from outside the lift cage, cables must be connected and the lift phone programmed before it is mounted. 6.2 frame mounting 1. Mark and pre-bore the holes...

  • Page 14

    Manual fältcom ecii se eng page 14 of 36 for the lift phone. The connections must be galvanically isolated. If they are not, or if the existing alarm button only has one connection, the button must be replaced to another type. Please note that there is a special version of the fältcom ecii se with a...

  • Page 15

    Manual fältcom ecii se eng page 15 of 36 information. For all alarm communication via the gsm network it is very important that it is investigated if the communication still works in case of power failure. The lift phone can also be connected to a voip system but then a special device must be mounte...

  • Page 16

    Manual fältcom ecii se eng page 16 of 36 6.5.4 connection via existing cable warning! Make sure there is no 230–400 v in cables that you will have contact with. Normally, the existing lift cable (usually a big flat conductor cable) goes to a cage cable box, where you may find unused wires (if any) t...

  • Page 17

    Manual fältcom ecii se eng page 17 of 36 note: this re-programming must be done while the dc/dc converter is connected. See more under section busy line function. 6.7 connection to loop amplifier to enable passengers with impaired hearing to communicate with alarm centre there is a possibility to co...

  • Page 18: 7 Programming

    Manual fältcom ecii se eng page 18 of 36 7 programming all programming i.E. Alarm numbers, codes to be sent and various function selections is done with the keypad on the back of the speech unit. For practical and ergonomically reasons it is recommended that all programming is done at (e.G. At a des...

  • Page 19

    Manual fältcom ecii se eng page 19 of 36 7.1 standard functions below follows a description of the most frequent programming sequences, which will be used by programming the fältcom ecii se. A number of special functions are presented below the next section. 7.1.1 activation of programming mode the ...

  • Page 20

    Manual fältcom ecii se eng page 20 of 36 1. If required, reset all old settings: 2. Enter phone number for alarm receiver 1: 3. Enter id number for alarm receiver 1: 4. Enter phone number for alarm receiver 2: 5. Enter id number for alarm receiver 2: for alarm receivers 3 to 6, use the keys: , , and...

  • Page 21

    Manual fältcom ecii se eng page 21 of 36 note that the alarm is transmitted 1 minute after completion of programming mode. 7.2 more available functions 7.2.1 change of time delay for alarm button you can change the time that the alarm button must be pressed down before an alarm is activated. The def...

  • Page 22

    Manual fältcom ecii se eng page 22 of 36 alarm function is active the first test alarm is sent 2 minutes after exiting programming mode. After that the test alarms is sent every n x 24 hours where n is the test alarm interval in days. Note that the lift phone counter is reset at every time programmi...

  • Page 23

    Manual fältcom ecii se eng page 23 of 36 7.2.6 alarm mode if the alarm mode function is active the fältcom ecii se can only receive incoming calls for 6 hours after the alarm was called out. After this time the lift phone will be closed for incoming calls until a new alarm is triggered. To activate ...

  • Page 24

    Manual fältcom ecii se eng page 24 of 36 where “1” is the identity of the lift from 1 - 6. Alarm mode function is disabled with: the active alarm mode is automatically disconnected after 6 hours but will be extended with 6 hours if a new speech connecting alarm is made or if a call is made to fältco...

  • Page 25

    Manual fältcom ecii se eng page 25 of 36 7.2.9 simplified acknowledge with this function it is possible to simplify the alarm receiving procedure when using a standard telephone as an alarm receiver. The function is activated with: and deactivated with when the function is active, all numeric button...

  • Page 26

    Manual fältcom ecii se eng page 26 of 36 the busy tone for the different groups looks like the following: the function is deactivated with: please note that not all telephone lines in all countries follow this pattern. Some internal switches may have a different busy tone and therefore this function...

  • Page 27

    Manual fältcom ecii se eng page 27 of 36 7.2.11 change of alarm flashing sequence when the alarm button has been activated and an alarm is registered by the lift phone, the led in the fältcom ecii se become yellow. When the alarm is acknowledge the led becomes green. This flashing sequence is accord...

  • Page 28

    Manual fältcom ecii se eng page 28 of 36 7.2.14 info alarm a simple info alarm function can be activated by programming: and deactivated with when the info alarm function is active, the last sequence alarm receiver is converted to an info alarm receiver. 60 seconds after an acknowledged alarm fältco...

  • Page 29: 8 Alarm

    Manual fältcom ecii se eng page 29 of 36 8 alarm receiving note that the lift phone should be connected to an alarm centre. En 81:1–2 stipulates connection to a twenty-four-hour manned telephone. By way of exception, it is possible to use an ordinary telephone or a mobile phone as alarm receiver. Th...

  • Page 30

    Manual fältcom ecii se eng page 30 of 36 a call will be disconnected automatically three minutes after the last key pressing. With thirty seconds to disconnection, a warning tone will be heard. To prolong the call, press 4, acknowledge . End the alarm call by pressing 0, end. If the alarm is ended w...

  • Page 31: 9 Troubleshooting

    Manual fältcom ecii se eng page 31 of 36 9 troubleshooting 9.1 lift phone cannot be programmed no power to the lift phone. For programming to be possible, the terminal strip marked ”tele” must be connected or external voltage connected via the dc/dc converter. 9.2 lift phone unable to call up 1. Not...

  • Page 32: 10 Technical Data

    Manual fältcom ecii se eng page 32 of 36 10 technical data supply voltage: (single mounted) none, if line voltage is higher than 32 vdc. If line voltage is between 20 vdc and 32 vdc an external power supply is required. This level can be even lower if the lift phone is mounted on an internal exchang...

  • Page 33: 11  Programming Key Map

    Manual fältcom ecii se eng page 33 of 36 11 programming key map in order for the emergency telephone to be programmed it has to be: 1) connected to the telephone line 2) be connected to the alarm button, and 3) be set to programming mode. It is assumed that an alarm button with breaking function is ...

  • Page 34

    Manual fältcom ecii se eng page 34 of 36 no. Programming sequence function def 12. Delay time to activate alarm button. Unit in seconds. 4 13. Activation of p100 protocol 14. Activation of cpc protocol x 15. Time between test alarms. Unit in days. 16. Deactivation of test alarm function x 17. Activa...

  • Page 35

    Manual fältcom ecii se eng page 35 of 36 no. Programming sequence function def 33. Disconnection of acknowledgement function 34. Disconnection of acknowledgement function and detection of busy tone 35. Reset to normal acknowledge sequence x 36. Activation of yellow/green led sequence at alarms x 37....

  • Page 36: 12 Contact Information

    Manual fältcom ecii se eng page 36 of 36 12 contact information fält communications ab kylgränd 6a se-906 20 umeÅ, sweden support: + 46 (0)90 18 39 27 or via e-mail: ec2.Support@faltcom.Se phone: + 46 (0)90 18 39 00 (exchange) fax: + 46 (0)90 18 39 29 homepage: www.Faltcom.Com service address: fält ...