Electrical and Structural Requirements
Lighting Options
Optional lighting fi tters and light kits are available, including a single bowl fi xture with a maximum of 180 watts and a
variety of four light fi xtures with a maximum of 240 watts. Can be only mounted on the motor switch cup. Installation
instructions provided with each light fi tter and light kit.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
If your fan is to replace an existing light fi xture, turn
electricity off at the main fuse box at this time and remove
the existing light fi xture.
Figure 3
2” Lag Bolt
& Flat Washer
(4 places)
2” Lag
Bolt
& Flat
Washer
(4 places)
Outlet Box Flush
to Finished
Ceiling
Plywood (¾˝ thick min.)
Backing Secured to
Structural Member
▲WARNING
Turning off wall switch is not sufficent. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and the
ceiling fan must be properly grounded as a precaution
against possible electrical shock. Follow all wiring
instructions carefully. Any electrical work not described
in these instructions should be done or approved by a
licensed electrician.
INSTALLATION NOTE
It is recommended that each fan and the motor have ¾˝
plywood backing secured to a structural member for
adequate support (Figure 3). A 120 VAC electrical feed,
centered under the motor unit and wired to a 3 speed
control (supplied) is required. The motor unit will not
operate more than 2 pulley/blade assemblies.