Fanstasy Spas ELUSION Owner's Manual - Filling The Spa With Water
15
FILL UP AND START-UP INSTRUCTIONS
The following procedures should be followed on initial startup and whenever the spa is drained for
routine maintenance.
FILLING THE SPA WITH WATER
1. Clear all the debris from your spa.
2. Be sure to open all jets to allow as much air as possible to escape from the plumbing during
the filling process.
3. Use a garden hose to fill your spa with water.
NOTE: Do not use hot or softened water.
4. As the water level rises, check inside the
equipment compartment for water leaks. It
may be necessary to tighten unions and/
or fittings that may have loosened during
delivery. There is no need to call for service;
this can easily be done. If assistance is
required, contact a Customer Service
representative at (888) 961-7727
5. Under normal circumstances keep the water
level half way between the top of the spa and
the top of the gray filter ring or just above the
highest jets (whichever is higher).
Failure to keep enough water in your spa
may result in damage to your system and
invalidate your warranty. If your spa filter is
sucking in air causing the pump to cavitate, you need to add water!
6. Check the filter installation and make sure the filter is not loose.
APPLYING POWER
1. Turn power to spa "ON" from the main panel at the house and the subpanel.
2. Press the Jets button on the topside control panel to activate the spa. Rotate all the air control
valves counterclockwise and observe the increased jet action (air mixed with water).
3. While the pump is running check again for water leaks at the drain spigot, unions, or fittings in
the equipment compartment (leaks may have occurred during transit). If water is leaking from
one of these areas, there is no need to call for service. Simply tighten the fitting. If assistance
is required, call a Customer Service representative at (888) 961-7727.
4. After checking your spa for leaks it is now time to adjust your spa settings. Press the Up or
Down button on your topside control panel until the display indicates your desired temperature
is set.
UNIONS
GATE VALVE