PROBLEM
It does not switch on
No sound when the keyboard is played.
The automatic accompaniment does not play.
No sound is produced when the MIDI data are reproduced
from a computer.
Reproduction on the keyboard produces an unnatural sound
when the keyboard is connected to a computer.
When a mobile phone is used you can hear a noise.
No sound is produced even when the keyboard is played or
reproducing a song.
Sound timbre changes from one note to the next.
Any other anomalies.
POSSIBLE CAUSE AND SOLUTION
Problem with the power supply.
Connect the adaptor correctly. Ensure that the battery poles (+/–) are facing the
correct direction, and control that the batteries are charged.
The volume is set at a level that is too low.
Use the VOLUME MASTER keys to raise the volume.
The accompaniment volume is set at 0.
Use the VOLUME SECTION keys to raise the volume.
The USB-MIDI cable is not connected properly.
Connect the USB-MIDI cable properly. Set MIDI DEVICE correctly.
The MIDI THRU function of the computer is activated.
Deactivate the MIDI THRU function of the computer.
The use of a mobile phone near to the computer may cause interference. To prevent
this problem, switch the mobile phone off or use it at a distance from the keyboard.
Control that the headphones are not connected to the PHONES/OUTPUT socket
of the rear panel. When headphone is connected to this socket, no sound is
transmitted.
The method of sound generation uses multiple recordings (samples) of one instrument
on the whole extension of the keyboard. It is therefore normal that the sound of the voice
differs slightly from note to note.
Switch off and then switch back on after a few seconds.
20. TROUBLE SHOOTING GUIDE
Attention: To avoid annoying whistling (Larsen effect), do not hold the microphone close to the speaker.
When using electrical products, basic precautions must be
followed, including the following:
1. Read all the instructions before using the product.
2. When the product is used by children, supervision by an
adult is advised.
3. Do not use the product near water, for example near a
bath tub, washbowl, kitchen sink, or near a swimming
pool etc., or in a wet or humid basement.
4. When connecting to the mains sup-
ply ensure that:
a) your hands are not wet (to avoid
electric shocks);
b) do not pull on the cable.
5. This product, either by itself, or when connected to an
external amplifier and headphones or speakers, is capa-
ble of producing sound levels that can cause damage to
hearing. Do not operate it for a long period of time at
high volume levels or in any case at an uncomfortable
volume level. Especially when using headphones, always
moderate the volume.
6. The product should be positioned
so that it’s location will provide
adequate ventilation.
7. The product should be positioned
away from heat sources such as
radiators, heaters or other pro-
ducts that produce heat.
8. This product should only be connected to a power sup-
ply of the voltage corresponding to that shown on the
label on the instrument using an AC/DC adaptor. This
label, containing all electrical data, relevant warning mes-
sages and the instrument identification data, can be
found on the underside of the product.
9. If the product is not used for long periods, the AC/DC
adaptor should be unplugged from mains.
10. The adaptor must be connected
directly to the mains supply
without any other plugs.
11. Do not obstruct the air entry points of the feeder with
objects such as curtains, cloths, etc.
12. Do not place the adaptor behind furniture or in hidden
places.
13. Do not place sticky or adhesive objects on the keyboard,
such as burning candles.
14. Care should be taken to avoid foreign objects falling into
or liquid being splilt into the inside of the instrument
through any of the slots or openings in the case.
15. Ensure that the adapter is sufficiently ventilated and that
the ventilation slits are not covered with objects such as
newpapers, tablecloths, curtains, etc..
16. Do not expose the keyboard or the adaptor to drops or
sprays of any kind of liquid.
17. This product should be referred to an approved service
centre when: a) It has been exposed to rain. b) It appears
to operate incorrectly or shows a marked change in per-
formance. c) It has been dropped or if the case has been
damaged. d) Objects have fallen into the instrument or
liquid has been spilt into or over it. e) The AC/DC adaptor
has been damaged.
18. Never attempt to repair your instrument yourself. Any
operation should be referred to authorized personnel,
otherwise the guarantee will be declared void.
19. Do not use alcohol, solvents or similar chemical substan-
ces for cleaning. Use a soft cloth dampened in a bland
solution of water and neutral detergent. Dip the cloth in
the solution and then wring it until it is nearly dry.
21. MAINTENANCE AND REMARKS
• Keep this manual for future reference •