Fast 1 For All TR7DRH Owner's Manual - page 19
About Advanced Features & Operation
Page 18
DEHUMIDIFICATION SETPOINT - If your HVAC unit is
equipped with a Dehumidification System
the thermostat will
provide power to the Misc. terminal on the backplate of the
thermostat when the Humidity in the home is below the
setpoint you have chosen and, when the humidity in the home
rises above the setpoint you have chosen, the Misc. terminal
will be deenergized. The value for this setpoint ranges from
25% to 50%, or OFF if no dehumidification is desired or if a
Dehumidification System has not been installed.
and the Humidity
Module has been installed, page 8,16,20,
COOL TO DEHUMIDIFY - The compressor will run with the fan
in this mode to reduce moisture in the air (step#19). This
feature will allo adjustment of the cooling overshoot of the
setpoint 0 to 5 (step#20).
DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is:
35 - 99 degrees in Fahrenheit and 2 - 36 degrees in Centi-
grade. When in the modes Heat or Cool, this adjustable
range is unhampered. When adjusting any Auto mode, inclu-
ding programming 4 Time periods, the thermostat will not
Heat setpoint to get closer to the Cool setpoint than
the value programmed as the minimum difference
step 9,
page 14. When entering the Auto mode from Cool, the Heat
and Cool setpoints will remain spread apart by the amount
that they were adjusted, prior to entering Auto. For example:
If the Cool setpoint was set to 80 while In the Cool mode and
the Heat setpoint was adjusted to 70 while in the Heat mode,
upon entering the Auto mode the Heat and Cool setpoints
would be 80 and 70. Both setpoints would then move up
and down together, (in this example spread by 10 degrees),
by pressing the up or down buttons. To move the Heat and
Cool setpoints closer together, enter the Cool or Heat mode
by pressing the Mode button, then adjust the setpoint(s)
closer together. Heat is limited to how close it can come to
Cool by step 9, page 14.
allow the
in