- DL manuals
- FCI
- Measuring Instruments
- FLT93B
- Installation, operation & maintenance manual
FCI FLT93B Installation, operation & maintenance manual - page 38
OPERATION FLT
®
Series FlexSwitch
TM
32
Fluid Components International LLC
0.00385 OHMS/OHMS/ºC 1000 OHM PLATINUM SENSORS
TEMPERATURE VERSUS VOLTAGE OUTPUT, FLT93
Temp Output
Voltage
°F
°C
Temp Output
Voltage
°F
°C
Temp Output
Voltage
°F
°C
Temp Output
Voltage
°F
°C
3.800
462
239
4.000
511
266
4.200
561
294
4.400
612
322
3.805
463
239
4.005
513
267
4.205
563
295
4.405
613
323
3.810
464
240
4.010
514
268
4.210
564
295
4.410
614
323
3.815
465
241
4.015
515
268
4.215
565
296
4.415
616
324
3.820
467
241
4.020
516
269
4.220
566
297
4.420
617
325
3.825
468
242
4.025
518
270
4.225
568
298
4.425
618
326
3.830
469
243
4.030
519
270
4.230
569
298
4.430
619
326
3.835
470
244
4.035
520
271
4.235
570
299
4.435
621
327
3.840
472
244
4.040
521
272
4.240
571
300
4.440
622
328
3.845
473
245
4.045
523
273
4.245
573
300
4.445
623
328
3.850
474
246
4.050
524
273
4.250
574
301
4.450
624
329
3.855
475
246
4.055
525
274
4.255
575
302
4.455
626
330
3.860
477
247
4.060
526
275
4.260
576
302
4.460
627
331
3.865
478
248
4.065
528
275
4.265
578
303
4.465
628
331
3.870
479
248
4.070
529
276
4.270
579
304
4.470
629
332
3.875
480
249
4.075
530
277
4.275
580
305
4.475
631
333
3.880
481
250
4.080
531
277
4.280
581
305
4.480
632
333
3.885
483
250
4.085
533
278
4.285
583
306
4.485
633
334
3.890
484
251
4.090
534
279
4.290
584
307
4.490
635
335
3.895
485
252
4.095
535
279
4.295
585
307
4.495
636
335
3.900
486
252
4.100
536
280
4.300
586
308
4.500
637
336
3.905
488
253
4.105
538
281
4.305
588
309
4.505
638
337
3.910
489
254
4.110
539
282
4.310
589
309
4.510
640
338
3.915
490
255
4.115
540
282
4.315
590
310
4.515
641
338
3.920
491
255
4.120
541
283
4.320
592
311
4.520
642
339
3.925
493
256
4.125
543
284
4.325
593
312
4.525
643
340
3.930
494
257
4.130
544
284
4.330
594
312
4.530
645
340
3.935
495
257
4.135
545
285
4.335
595
313
4.535
646
341
3.940
496
258
4.140
546
286
4.340
597
314
4.540
647
342
3.945
498
259
4.145
548
286
4.345
598
314
4.545
649
343
3.950
499
259
4.150
549
287
4.350
599
315
4.550
650
343
3.955
500
260
4.155
550
288
4.355
600
316
4.555
651
344
3.960
501
261
4.160
551
288
4.360
602
316
4.560
652
345
3.965
503
261
4.165
553
289
4.365
603
317
4.565
654
345
3.970
504
262
4.170
554
290
4.370
604
318
4.570
655
346
3.975
505
263
4.175
555
291
4.375
605
319
4.575
656
347
3.980
506
264
4.180
556
291
4.380
607
319
4.580
657
347
3.985
508
264
4.185
558
292
4.385
608
320
4.585
659
348
3.990
509
265
4.190
559
293
4.390
609
321
4.590
660
349
3.995
510
266
4.195
560
293
4.395
610
321
4.595
661
350
Table 3-7. Temperature versus Voltage Output - Page 4
Summary of FLT93B
Page 1
Flt ® 93 series flexswitch ™ flow, level, temperature switch / monitor models: flt93b, flt93c, flt93f, flt93l, flt93s installation, operation & maintenance manual installation, betrieb und wartungshandbuch manual de instalación, operación y mantenimiento 安装、操作和维护手册 fluid components international llc...
Page 2
Flt ® series flexswitch tm fluid components international llc notice of proprietary rights this document contains confidential technical data, including trade secrets and proprietary information which is the property of fluid components international llc (fci). Disclosure of this data to you is expr...
Page 3
Flt ® series flexswitch tm 06en003401 rev. C fluid components international llc iii table of contents 1 general................................................................................................................................................................................................
Page 4
06en003401 rev. C flt ® series flexswitch tm iv fluid components international llc liquid flow applications .............................................................................................................................................................................................23 ...
Page 5
Flt ® series flexswitch tm 06en003401 rev. C fluid components international llc v appendix a drawings .........................................................................................................................................................................45 appendix b glossary .........
Page 6
06en003401 rev. C flt ® series flexswitch tm vi fluid components international llc intentionally left blank.
Page 7
Flt ® series flexswitch tm general fluid components international llc 1 1 general description the flt series models are multipurpose measurement instruments. The models included in this manual are flt93b (basic), flt93c (sanitary), flt93f (fast response), flt93l (in-line) and flt93s (heavy duty). Ea...
Page 8
General flt ® series flexswitch tm 2 fluid components international llc application flow rate and/or level/interface and temperature sensing in liquid, gas and slurry applications. Sensing element process connection model b standard: 3/4” male npt. Models s and f standard: 3/4” male npt. Optional: 1...
Page 9
Flt ® series flexswitch tm general fluid components international llc 3 the above typical service power selections are for reference only. De- pending on application requirements, surface temperature rating require- ments, and rangeability expectations, alternate power selections may be recommended....
Page 10
General flt ® series flexswitch tm 4 fluid components international llc intentionally left blank.
Page 11
Flt ® series flexswitch tm installation fluid components international llc 5 2 installation receiving/inspection • unpack carefully. • verify that all items in the packing list are received and are correct. • inspect all instruments for damage or contaminants prior to installation. If the above thre...
Page 12
Installation flt ® series flexswitch tm 6 fluid components international llc figure 2-1 npt pipe thread mount figure 2-2 flange mount install the sensing element male npt mounting when mounting the sensing element to the process pipe, it is important that a lubricant/sealant be applied to the male t...
Page 13
Flt ® series flexswitch tm installation fluid components international llc 7 packing gland assembly for applications involving the use of a packing gland (low or medium pressure) refer to the drawings in appendix a for additional detail. 1. Threaded or flanged packing gland mounts are available. The...
Page 14
Installation flt ® series flexswitch tm 8 fluid components international llc sanitary assembly (flt93c) the instrument is inserted into the process connection with removable clamp fittings. The removable clamp (rc) sanitary assembly contains a removable clamp connection to the flow element. The clea...
Page 15
Flt ® series flexswitch tm installation fluid components international llc 9 figure 2-5 removing ground wire securing hardware from enclosure cable and conduit entry devices the cable and conduit entry devices and blanking elements shall be of a certified flameproof type ex db and ex tb suitable for...
Page 16
Installation flt ® series flexswitch tm 10 fluid components international llc 3. Place center of ring lug barrel in appropriate crimping tool chamber. Squeeze tool handles together with just enough force to hold barrel in place (do not deform barrel). 4. Insert stripped end of ground wire into barre...
Page 17
Flt ® series flexswitch tm installation fluid components international llc 11 figure 2-8 local wiring diagram wiring the local enclosure configuration warning: ensure that all power is off before wiring any circuit. This procedure is for instruments with the control circuit located in the sensing el...
Page 18
Installation flt ® series flexswitch tm 12 fluid components international llc wiring the remote enclosure configuration this procedure is for instruments with the control circuit located remotely (remote housing) from the sensing element (local enclosure). Locate the remote hardware location warning...
Page 19
Flt ® series flexswitch tm installation fluid components international llc 13 wiring output signal terminals the primary outputs on the flt are the relays. Voltage ouputs relative to flow/level and temperature are provided on the terminal board at tb3. The signal voltage at positions 1 and 2 represe...
Page 20
Installation flt ® series flexswitch tm 14 fluid components international llc figure 2-7 power jumper diagram.
Page 21
Flt ® series flexswitch tm installation fluid components international llc 15 figure 2-8 120 vac input power wiring diagram figure 2-9 230 vac input power wiring diagram.
Page 22
Installation flt ® series flexswitch tm 16 fluid components international llc figure 2-13 24 vac/vdc input power wiring diagram figures 2-11, 2-12 and 2-13 can be cross referenced in appendix a with fci drawings 022580 [wiring diagram flt93/5208 integral control circuit] and 022581 [wiring diagram f...
Page 23
Flt ® series flexswitch tm operation fluid components international llc 17 3 operation caution: the control circuit contains electrostatic discharge (esd) sensitive devices. Use standard esd precautions when handling the control circuit. See section 2, operation, for esd details. Factory default jum...
Page 24
Operation flt ® series flexswitch tm 18 fluid components international llc alarm setpoint adjustments numerical adjustment versus adjustment by observation an alarm setpoint is established using either numerical adjustment or adjustment by observation. The adjustment by observation requires the cust...
Page 25
Flt ® series flexswitch tm operation fluid components international llc 19 jumper j32 j12 j13 j14 j33 flt93s/flt93b element wattage (110-ohm heater) 3 watts 1.75 watts 0.75 watts* 0.21 watts off flt93f element wattage (560-ohm heater) 0.57 watts 0.52 watts 0.49 watts 0.25 watts* off *j13 is standard...
Page 26
Operation flt ® series flexswitch tm 20 fluid components international llc figure 3-2 5208 control circuit component locations 9. Follow either the detecting decreasing flow or the detecting increasing flow procedure for each flow application alarm. Detecting decreasing flow (low flow alarm) 1. Stop...
Page 27
Flt ® series flexswitch tm operation fluid components international llc 21 detecting increasing flow (high flow alarm) 1. Establish the excessive process flow condition and allow the signal to stabilize. 2. Record the high flow signal. Observe that the high flow signal is less than the normal flow s...
Page 28
Operation flt ® series flexswitch tm 22 fluid components international llc 6. Disconnect the voltmeter from p1. 7. Replace the enclosure cover. Note: the alarm can be set for a specific flow rate. Follow the air/gas flow applications procedure up to step 7 except establish the specific flow rate rat...
Page 29
Flt ® series flexswitch tm operation fluid components international llc 23 11. Determine the setpoint by calculating the average of the wet and dry output signals; e.G., if the wet signal is 0.200 volts and the dry signal is 4.000 volts, then the calculated setpoint would be 2.100 volts. 12. Record ...
Page 30
Operation flt ® series flexswitch tm 24 fluid components international llc note: the output signal at connector p1 varies inversely with changes in the process flow rate. The output signal level is also rela- tive to the type of process media being measured. See figure 3-3. 7. Establish the normal p...
Page 31
Flt ® series flexswitch tm operation fluid components international llc 25 for the appropriate alarm, determine whether the status led is on or off (red for no. 1 or green for no. 2). If the led is on, turn the setpoint adjustment potentiometer (r26 for alarm no. 1 or r25 for alarm no. 2) slowly cou...
Page 32
Operation flt ® series flexswitch tm 26 fluid components international llc level applications 1. Ensure that the instrument has been properly installed in the vessel. 2. Apply power to the instrument. Allow fifteen minutes for the sensing element to stabilize. 3. Remove the enclosure cover to access...
Page 33
Flt ® series flexswitch tm operation fluid components international llc 27 detecting increasing temperature (high temperature alarm) 1. Move the mode switch to the cal position. 2. Adjust the calibrate potentiometer (r24) until the voltmeter equals the desired temperature signal as indicated in tabl...
Page 34
Operation flt ® series flexswitch tm 28 fluid components international llc converting temp out voltage to temp in degrees f or degrees c this formula is useful when monitoring the temperature output voltage with a data acquisition system where the formula can be used in the program. Use the followin...
Page 35
Flt ® series flexswitch tm operation fluid components international llc 29 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 1.400 -104 -76 1.600 -59 -51 1.80...
Page 36
Operation flt ® series flexswitch tm 30 fluid components international llc 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 2.200 78 26 2.400 125 52 2.600 17...
Page 37
Flt ® series flexswitch tm operation fluid components international llc 31 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 3.000 267 130 3.200 315 157 3.400...
Page 38
Operation flt ® series flexswitch tm 32 fluid components international llc 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 3.800 462 239 4.000 511 266 4.200...
Page 39
Flt ® series flexswitch tm operation fluid components international llc 33 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 4.600 663 350 4.800 714 379 5.000...
Page 40
Operation flt ® series flexswitch tm 34 fluid components international llc fail-safe alarm setting these procedures set the second relay to detect component failure (fail-safe). Low flow alarm settings install the following jumpers for the low flow fail-safe setup: j18, j20, j23, j24, j27. The follo...
Page 41
Flt ® series flexswitch tm operation fluid components international llc 35 low level alarm settings (sensing element normally wet) install the following jumpers for the low level fail-safe setup: j18, j20, j23, j24, j27. The following information is assumed: relay is de-energized in the alarm condit...
Page 42
Operation flt ® series flexswitch tm 36 fluid components international llc intentionally left blank.
Page 43
Flt ® series flexswitch tm maintenance fluid components international llc 37 4 maintenance warning: to avoid hazards to personnel, ensure that all environmental isolation seals are properly maintained. Caution: the insturment contains electrostatic discharge (esd) sensitive devices. Use standard esd...
Page 44
Maintenance flt ® series flexswitch tm 38 fluid components international llc intentionally left blank.
Page 45
Flt ® series flexswitch tm troubleshooting fluid components international llc 39 5 troubleshooting warning: only qualified personnel should attempt to test this instrument. The operator assumes all responsibilities for safe practices while troubleshooting. Caution: the control circuit contains elect...
Page 46
Troubleshooting flt ® series flexswitch tm 40 fluid components international llc troubleshooting the flow element use tables 5-1 and 5-2 to determine if the flow element is wired correctly or has failed. Turn off the input power to the instrument. Unplug the control circuit from its socket and measu...
Page 47
Flt ® series flexswitch tm troubleshooting fluid components international llc 41 figure 5-1 terminal board, test points.
Page 48
Troubleshooting flt ® series flexswitch tm 42 fluid components international llc troubleshooting the control circuit 1 is the yellow power indicator led: dim, off or blinking yellow led dim or off with the power applied, measure the 9-volt reference voltage at p1, pins 2 (blue) to 4 (black). See fig...
Page 49
Flt ® series flexswitch tm troubleshooting fluid components international llc 43 4 signal voltage observation with the power applied, note the position of the heater wattage control jumper plug and remove it. Place the jumper plug temporally on position j33. With a voltmeter measure the voltage at p...
Page 50
Troubleshooting flt ® series flexswitch tm 44 fluid components international llc intentionally left blank.
Page 51
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 45 appendix a drawings 3/4” npt with local hazardous location type 4x enclosure.
Page 52
Appendix a - drawings flt ® series flexswitch tm 46 fluid components international llc 3/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 53
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 47 1” npt with local hazardous location type 4x enclosure.
Page 54
Appendix a - drawings flt ® series flexswitch tm 48 fluid components international llc 1” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 55
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 49 flanged with local hazardous location type 4x enclosure.
Page 56
Appendix a - drawings flt ® series flexswitch tm 50 fluid components international llc flanged with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 57
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 51 1-1/4” npt low pressure packing gland with local hazardous location type 4x enclosure.
Page 58
Appendix a - drawings flt ® series flexswitch tm 52 fluid components international llc 1-1/4” npt low pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 59
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 53 flanged low pressure packing gland with local hazardous location type 4x enclosure.
Page 60
Appendix a - drawings flt ® series flexswitch tm 54 fluid components international llc flanged low pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 61
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 55 1-1/4” npt, medium pressure packing gland with local hazardous location type 4x enclosure.
Page 62
Appendix a - drawings flt ® series flexswitch tm 56 fluid components international llc 1-1/4” npt, medium pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 63
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 57 flanged, medium pressure packing gland with local hazardous location type 4x enclosure.
Page 64
Appendix a - drawings flt ® series flexswitch tm 58 fluid components international llc flanged, medium pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 65
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 59 3/4” mnpt compression fitting with local hazardous location type 4x enclosure.
Page 66
Appendix a - drawings flt ® series flexswitch tm 60 fluid components international llc 3/4” mnpt compression fitting with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 67
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 61 flanged compression fitting with local hazardous location type 4x enclosure.
Page 68
Appendix a - drawings flt ® series flexswitch tm 62 fluid components international llc flanged compression fitting with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 69
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 63 flt93f style head : 1/4” npt with local hazardous location type 4x enclosure.
Page 70
Appendix a - drawings flt ® series flexswitch tm 64 fluid components international llc flt93f style head: 1/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 71
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 65 flt93l: 3/4” npt with local hazardous location type 4x enclosure.
Page 72
Appendix a - drawings flt ® series flexswitch tm 66 fluid components international llc flt93l: 3/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 73
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 67 flt93l: 1” npt with local hazardous location type 4x enclosure.
Page 74
Appendix a - drawings flt ® series flexswitch tm 68 fluid components international llc flt93l: 1” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 75
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 69 flt93l: flanged with local hazardous location type 4x enclosure.
Page 76
Appendix a - drawings flt ® series flexswitch tm 70 fluid components international llc flt93l: flanged with local hazardous location type 4x enclosure: 3-port remote type 4x.
Page 77
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 71 flt93c : sanitary flange with local hazardous location type 4x enclosure.
Page 78
Appendix a - drawings flt ® series flexswitch tm 72 fluid components international llc flt93 surface mount: local wiring diagram.
Page 79
Flt ® series flexswitch tm appendix a - drawings fluid components international llc 73 flt93 surface mount : remote wiring diagram.
Page 80
Appendix a - drawings flt ® series flexswitch tm 74 fluid components international llc flt93 pwb module: 5208.
Page 81
Flt ® series flexswitch tm appendix b - glossary fluid components international llc 75 appendix b glossary abbreviations delta-r (dr) differential resistance delta-t (dt) differential temperature dmm digital multimeter dpdt double pole double throw fci fluid components intl htr heater led light emit...
Page 82
Appendix b - glossary flt ® series flexswitch tm 76 fluid components international llc intentionally left blank.
Page 83
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 77 appendix c approval information ec information.
Page 84
Appendix c - approval information flt ® series flexswitch tm 78 fluid components international llc intentionally left blank.
Page 85
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 79 safety instructions for the use of the flt93 flowswitch in hazardous areas approval kema 02atex2166 x and approval iec certificate iecex dek14.0080x for: integral version: ii 2 g ex db iic t4…t2 gb ii ...
Page 86
Appendix c - approval information flt ® series flexswitch tm 80 fluid components international llc gb irl english- safety instructions these safety instructions are valid for the fluid components, flt93 flowswitch to the ec type approval certificate no. Kema 02 atex 2166 (certificate number on the t...
Page 87
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 81 f b l consignes de sécurité ces consignes de sécurité sont valables pour le modèle flt93 flowswitch de la société fluid components (fci) conforme au certificat d’épreuves de type kema 02 atex 2166 (num...
Page 88
Appendix c - approval information flt ® series flexswitch tm 82 fluid components international llc p português - normas de segurança estas normas de segurança são válidas para os fluid components, flt93 flowswitch conforme o certificado de teste de modelo n.º kema 02 atex 2166 (número do certificado...
Page 89
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 83 annex 1 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 1 of 5 form...
Page 90
Appendix c - approval information flt ® series flexswitch tm 84 fluid components international llc annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 2 of 5 pos. Explana...
Page 91
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 85 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 3 of 5 model decodi...
Page 92
Appendix c - approval information flt ® series flexswitch tm 86 fluid components international llc annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 4 of 5 thermal data...
Page 93
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 87 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 5 of 5 pigtail vers...
Page 94
Appendix c - approval information flt ® series flexswitch tm 88 fluid components international llc intentionally left blank.
Page 95
Flt ® series flexswitch tm appendix c - approval information fluid components international llc 89 sil information.
Page 96
Appendix c - approval information flt ® series flexswitch tm 90 fluid components international llc intentionally left blank.
Page 97
Flt ® series flexswitch tm appendix d - temp comp fluid components international llc 91 appendix d temperature compensation introduction temperature compensation (temp comp) is an essential part of the flt flexswitch circuitry. When the temp comp is set correctly, the instru- ment stays accurate ove...
Page 98
Appendix d - temp comp flt ® series flexswitch tm 92 fluid components international llc balance procedure the following steps are the flow element balance procedure required to complete the temp comp restoration and must be used when install- ing remote units with more than 10 feet of cable. 1. Conn...
Page 99
Flt ® series flexswitch tm appendix d - temp comp fluid components international llc 93 power supply settings flt93s 3 watts 1.75 watts 0.75 watts 0.21 watts set for 18.0 vdc set for 13.8 vdc set for 9.0 vdc set for 4.9 vdc flt93f 0.57 watts 0.52 watts 0.49 watts 0.25 watts set for 18.0 vdc set for ...
Page 100
Appendix d - temp comp flt ® series flexswitch tm 94 fluid components international llc temp comp r5 r8 factor k ohms k ohms 0.042 119.75 263.16 0.041 119.88 256.41 0.04 120.00 250.00 0.039 120.13 243.9 0.038 120.25 238.10 0.037 120.38 232.56 0.036 120.5 227.27 0.035 120.63 222.22 0.034 120.75 217.3...
Page 101
Flt ® series flexswitch tm appendix e - customer service fluid components international llc 95 appendix e customer service customer service/technical support fci provides full in-house technical support. Additional technical representation is also provided by fci field representatives. Before contac...
Page 102
Appendix e - customer service flt ® series flexswitch tm 96 fluid components international llc non-warranty repairs or returns fci returns repaired equipment to the customer either collect or prepaid and adds freight charges to the customer invoice. Extended warranty an extended warranty is availabl...
Page 103
Flt ® series flexswitch tm appendix e - customer service fluid components international llc 97.
Page 104
Appendix e - customer service flt ® series flexswitch tm 98 fluid components international llc.
Page 105
Flt ® series flexswitch tm appendix e - customer service fluid components international llc 99 warranties goods furnished by the seller are to be within the limits and of the sizes published by the seller and subject to the seller’s standard tolerances for variations. All items made by the seller ar...
Page 106
Flt ® series flexswitch tm fluid components international llc 06en003401 rev. C fci’s complete customer commitment. Worldwide iso 9001 and as9100 certified notice of proprietary rights this document contains confidential technical data, including trade secrets and proprietary information which is th...