Federal Signal Corporation EXI MIC1 Installation And Service Instructions Manual - page 5
-3-
B. Replacement Parts.
Contactthefactoryforsparepartsavailabilityandpartnumbers.
III. CERTIFICATION.
Model:
ExiMICIMicrophone
CertifiedTo:
EN60079-0:2006Electricalapparatusforexplosivegasatmospheres
-Part0:Generalrequirements.
EN60079-11:2007Explosiveatmospheres-Part11:Equipment
protection by intrinsic safety “i”.
CertificateNo:
Baseefa07ATEX0105X
ATEXCoding:
1G
Protection:
ExiaIICT6
Temperature:
-35°Cto+50°C
Where:-
indicatescompliancewithdirective94/9/EC
hexagonsymbol,thespecificmarkingofexplosionprotection
1
indicatessuitabilityforuseinaZone0area
G
indicatessuitabilityforuseinthepresenceofgases
ia
indicates intrinsically safe protection
IIC
indicatesgasgroupAcetylene&Hydrogen
T6
indicatesamaximumsurfacetemperatureof85°C(185°F)
Input Parameters:
MaxVoltage(Ui)=12V
MaxCurrent(Ii)=26mA
MaxCapacitance(Ci)=0
MaxInductance(Li)=25.2mH
ConditionsofSafeUse:
Thisapparatusmustbeearthedtoreduceriskofelectrostaticcharging.