Federal Signal Corporation P-LS2B Installation, Operation And Maintenance Instructions - Specific Condition Of Use
9
PAGASYS Series Loudspeaker
Specific Condition of Use
• Except when shown in a certificate as being the internal wiring
of the apparatus, not more than one single or multiple-stranded
lead shall be connected into either side of any terminal, unless
multiple conductors have been joined in a suitable manner, e.g., two
conductors into a single insulated crimped boot-lace ferrule.
• Leads connected to terminals shall be insulated for the appropriate
voltage, and this insulation shall extend to within 1 mm (0.04 in) of
the metal of the terminal throat.
• All terminal screws, used and unused, shall be tightened down to
between 0.5 N·m to 0.7 N·m (4.4 in-lb to 6.2 in-lb).
Condição específica de uso:
• Exceto quando mostrado em um certificado como sendo a
fiação interna do aparelho, não mais do que um cabo unipolar
ou multipolar poderá ser conectado em qualquer dos lados de
uma dada terminal, a menos que condutores múltiplos tenham
sido unidos de uma forma adequada, por exemplo, dois
condutores em um único conduíte corrugado isolado.
• Os cabos conectados às terminais deverão ser isolados para a
voltagem adequada e esse isolamento deverá estender-se a
1 mm (0,04 polegadas) do metal da garganta da terminal.
• Todos os parafusos das terminais, estejam as mesmas em
uso ou não, deverão ser apertados de 0,5 N • m a 0,7 N • m.
(4,4 polegadas-libras a 6,2 polegadas-libras).
Mounting the Loudspeaker
DRILLING PRECAUTIONS
When drilling holes, check the area into which you are drilling
to be sure you do not damage anything while drilling. All drilled
holes should be de-burred and all sharp edges should be
smoothed.
The Models P-LS2B and P-LS2C Series loudspeakers are designed for
mounting on a flat horizontal or vertical surface.
To mount the loudspeaker, obtain M6 stainless steel bolts, lockwashers,
and flat washers.