Configuration Menu
Range and scaling
0/600Vdc = 0/600.0
Decimal point
XXX.X
Alarms 1,2,3 and 4
Active
Off (not managed)
Type
maximum
Setpoint
1000
Hysteresis
0 counts
Delay
0.0 seconds
Setpoint2
Off
Display
Fixed digits
Off
Average
Off
Steps
Off
Left zeros
Off
Add zero to the right Off
Memory of maximum -9999
Memory of minimum 9999
Peak & Hold
Off
Tools
Password
Off
Brightness
3
Default factory configuration
Configuration Menu - Operation
To enter the “Configuration Menu” press the SQ button. The
“Configuration Menu” allows to change the configuration of the
instrument. Access to the “Configuration Menu” can be pass-
word protected with the function “PASSWord”. During operation
with the “Configuration Menu” the alarms are kept “on-hold”.
When leaving the “Configuration Menu” the instrument performs
a restart, and new configuration is applied. During the restart of
the instrument, a short alarm deactivation is performed.
Configuration Menu Tree - See page 6 and 7.
Description of Configuration Menu functions - See page
8 and 9.
Rollback - After 30 seconds without interaction from the
operator, the instrument leaves the “Configuration Menu”,
discarding all changes.
Button SQ - Moves horizontally on the menu. Allows selec-
tion of the current option displayed. During a value selection
menu (for example a setpoint value) validates the value on
display.
Button UP - Moves vertically on the menu. Displays the
available menu options. During a value selection menu (for
example a setpoint value) increases digit value from 0 to 1,
2, 3, 4, 5, 6, 7, 8, 9.
Button LE - Leaves the current menu. Pressing LE several
times will leave all menus and leave the “Configuration Menu”
tree. During a value selection menu (for example a setpoint
value) allows to select each digit for modification with the
UP button.
Reset - Leaving the “Configuration Menu” forces a restart of
the instrument, even in case of no changes in configuration.
Input
Press LE to change selection
Scaling
Input Low
Display Low
Input High
Display High
Decimal Point
Alarm1
Setpoint
Hysteresis
Delay
Active = On
Inactive = Off
Max=Maximum
Min= Minimum
Alarm
management
Alarm as max.
Alarm as min.
Counts
Seconds
Auto correction
Auto High
Auto Low
Alarms
Signal Low
Display Low
Signal High
Display High
Range ±600Vdc
Range ±100Vdc
Range ±10Vdc
Range ±1Vdc
Range ±5Adc
Range ±1Adc
Range ±100mVdc