    6 co d . 3 5 4 0 s 5 6 2 — 0 1 /2 0 1 1 (r ev . 0 0 ) econcept 51 a it - istruzione per l’uso l'installazione e la manutenzione es - instrucciones de uso, instalaciÓn y mantenimiento tr - kullanma, kurulum ve bak øm talimatlarø en - instructions for use, installation and maintenance fr - instruction...

  • Page 2

    Econcept 51 a 38 en cod. 3540s562 - 01/2011 (rev. 00) en 1. General instructions • carefully read the instructions contained in this instruction booklet. • after boiler installation, inform the user regarding its operation and give him this manual, which is an integral and essential part of the prod...

  • Page 3

    Econcept 51 a 39 en cod. 3540s562 - 01/2011 (rev. 00) turning the boiler off press the button eco comfort (detail 7 - fig. 1) for 5 seconds. Fig. 5 - turning the boiler off when the boiler is turned off, the pcb is still powered. Domestic hot water (with optional hot water tank installed) and heatin...

  • Page 4

    Econcept 51 a 40 en cod. 3540s562 - 01/2011 (rev. 00) if the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Proceed by increasing or decreasing in steps of one and check the result in the room. Fig. 12 - compensation curves fig. 13 - ex...

  • Page 5

    Econcept 51 a 41 en cod. 3540s562 - 01/2011 (rev. 00) hot water tank connection (optional kit -) the optional kit - is available for connection to an external hot water tank. The kit, which comprises a circulating pump (ref. 130 - fig. 15), hot water tank probe (ref. S - fig. 15) and plumbing fittin...

  • Page 6

    Econcept 51 a 42 en cod. 3540s562 - 01/2011 (rev. 00) one direct heating circuit and one dhw circuit with diverter valve check/change parameter p02 of the "transparent parameters menu" to 3. Change parameter p.02 of the "system type menu" to 1. Change parameter p.09 of the "system type menu" to 1. C...

  • Page 7

    Econcept 51 a 43 en cod. 3540s562 - 01/2011 (rev. 00) accessing the electrical terminal block the electrical terminal block is located inside a sealed box at the bottom left of the cab- inet. Make the electrical connections as shown in the wiring diagram on fig. 37 and run the cables through the spe...

  • Page 8

    Econcept 51 a 44 en cod. 3540s562 - 01/2011 (rev. 00) connection with coaxial pipes fig. 25 - examples of connection with coaxial pipes ( = air / = fumes) for coaxial connection, fit the unit with one of the following starting accessories. For the wall hole dimensions, refer to fig. 33. Any horizont...

  • Page 9

    Econcept 51 a 45 en cod. 3540s562 - 01/2011 (rev. 00) test mode activation press the heating buttons (details 3 and 4 - fig. 1) at the same time for 5 seconds to ac- tivate the test mode. The boiler lights at the maximum heating power set as described in the following section. The heating symbol (de...

  • Page 10

    Econcept 51 a 46 en cod. 3540s562 - 01/2011 (rev. 00) table of faults table. 5 - fault list 5. Technical data and characteristics 5.1 dimensions and connections fig. 33 - dimensions and connections 1 = system delivery - Ø 3/4” 3 = gas inlet - Ø 3/4” 5 = system return - Ø 3/4” 5.2 general view and ma...

  • Page 11

    Econcept 51 a 47 en cod. 3540s562 - 01/2011 (rev. 00) 5.3 plumbing circuit fig. 35 - plumbing circuit key fig. 34 and fig. 35 - fig. 37 5 sealed chamber 7 gas inlet 10 system delivery 11 system return 14 safety valve 16 fan 19 combustion chamber 22 burner 32 heating circulating pump 36 automatic air...

  • Page 12

    Econcept 51 a 48 en cod. 3540s562 - 01/2011 (rev. 00) 5.6 wiring diagram fig. 37 - wiring diagram t° t° 230v 50hz 16 278 191 186 114 16 32 82 81 v1 v2 44 x1 x3 x2 98 l n 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 fuse 3.15a 25 26 27 28 29 30 1 2 3 4 1 2 3 4 5 6 dsp12c x01 x04 x03 x0...

  • Page 13: Uygunluk Beyani

    Declaración de conformidad el fabricante: ferroli s.P.A. Dirección: via ritonda 78/a 37047 san bonifacio (verona) declara que este equipo satisface las siguientes directivas cee: • directiva de aparatos de gas 90/396 • directiva de rendimientos 92/42 • directiva de baja tensión 73/23 (modificada por...

  • Page 14: Declara

    Ⱦɟɤɥɚɪɚɰɿɹ ɩɪɨ ɜɿɞɩɨɜɿɞɧɿɫɬɶ ȼɢɪɨɛɧɢɤ: ɤɨɦɩɚɧiɹ ferroli s.P.A. ɡɚ ɚɞɪɟɫɨɸ: via ritonda 78/a 37047 san bonifacio vr ɡɚɹɜɥɹɽ, ɳɨ ɰɟɣ ɚɩɚɪɚɬ ɜɿɞɩɨɜɿɞɚɽ ɭɫɿɦ ɧɚɫɬɭɩɧɢɦ Ⱦɢɪɟɤɬɢɜɚɦ ȯɋ: • Ⱦɢɪɟɤɬɢɜɚ ȯɋ 90/396 (Ⱦɢɪɟɤɬɢɜɚ ɩɪɨ ɡɛɥɢɠɟɧɧɹ ɩɪɚɜɨɜɢɯ ɧɨɪɦ ɤɪɚʀɧ-ɱɥɟɧɿɜ ȯɋ ɞɥɹ ɝɚɡɨ-ɪɨɡɯɿɞɧɢɯ ɭɫɬɚɧɨɜɨɤ) • Ⱦɢɪɟɤɬɢɜɚ ȯɋ...

  • Page 16

    Ferroli s.P.A. Via ritonda 78/a 37047 san bonifacio - verona - italy www.Ferroli.It.