Ferroli MODENA S HE Specifications - page 7
Digital RF Programmable
Room Thermostat
Mechanical RF Programmable
Room Thermostat
H
H
I
J,K
B
I
Q
A
G
I
I
M
N
F
L
D,E
C
Likely flue positions requiring
a flue terminal guard
P
Q
A
P
N
M
I
G
I
H
H
K
J
Q
C
I
Q
D E
B
F
L
Flue Terminal Positions
mm
Directly below an opening, air brick, opening windows etc.
300
Above an opening, air brick, opening windows etc.
300
Horizontally to an opening, air brick, opening windows etc.
300
Below gutters, soil pipes or drain pipes
75
Below eaves
200
Below balconies or car port
200
From a vertical drain pipe or soil pipe
150
From an internal or external corner
100
Above ground roof or balcony level
300
From a surface facing the terminal
600
From a terminal facing the terminal
1200
From an opening in the car port (ie. door, window) into the dwelling 1200
Vertically from a terminal on the same wall
1500
Horizontally from a terminal on the same wall
300
From the wall on which the terminal is mounted
N/A
From a vertical structure on the roof
150
Above intersection with roof
300
300 min
Terminal
Assembly
Top View
Rear Flue
Property
Boundary Line
Notes
In addition, the terminal must not be nearer than
300mm to an opening in the building fabric
formed for the purpose of accommodating a
built-in element such as a window frame.
Condensing terminal positions: if the flue is
to be terminated at low level then the potential
effect of the plume must be considered.
The plume should not be directed:
– across a frequently used access route
– towards a window
– across a neighbouring property
For more information on terminal positions
please contact our technical department.
The distance from a fanned draught appliance
terminal installed parallel to a boundary may not
be less than 300mm in accordance with the
diagram below.
Flue terminal positions