If the light inside the cabinet does not
work:
•
the lamp is broken
-replace the lamp.
Lamp type:
PL TUBE 7W, base G 23
Changing the lamp:
•
Stop the mechanism using the ope-
rating switch of the cabinet
•
Take the plug out of the wall socket
•
Disconnect the plastic lid of interior
light by opening three cross head
screws.
•
Change the lamp.
•
Connect the plastic lid of interior
light.
•
Push the plug into the wall socket.
•
Press switch (I) on.
E6 + sound signal = too low tempereture.
Failure comes into view after one hour the
temperature has gone below +2°C.
Acknowledge and stop the sound signal by
pressing the button of the display.
E6 will remain on the display.
Please contact the Festivo-service
organization.
E7 + sound signal = contact fault between
display and adjuster.
Acknowledge and stop the sound signal by
pressing the button of the display.
E7 will remain on the display.
Please contact the Festivo-service orga-
nization.
Look first at page 11, Functional
disorders.
If the above-mentioned functions are in
order, but the appliance does not begin
cooling within about two hours, please contact
the Festivo-service organization.
Error messages
E2 + sound signal = sensor fault.
Acknowledge and stop the sound signal by
pressing the button of the display.
E2 will remain on the display.
Please contact the Festivo-service orga-
nization.
E3 +sound signal = too high temperature.
The error message will appear one hour
after the temperature exceeds +23°C.
Acknowledge and stop the sound signal by
pressing the button of the display.
E3 will remain on the display.
Please contact the Festivo-service orga-
nization.
DISCARDED COLD STORAGE APPLIAN-
CES ARE HAZARDOUS WASTE
By a law amendment that came into force on
1st January 2002, discarded cold storage
appliances are classed in the whole EU
area as hazardous waste.
Disposal of the appliance
Take care not to damage the refrigerant
pipes of the winecabinet before or during
transport to an authorised collection depot.
So refrigerant in the pipework and oil in the
compressor will be contained, and will not
leak out into the environment.