8
ECO MODE-Energy saving mode DEFINITONS
If Selected: Turns heaters off after 1 hour of inactivity.
The hot water tank temperature will slowly decline to no lower than 60°C/170°F
A screen (example to the right) will display showing “ECO Mode” is activated. Æ
To return from ECO-Mode
Tap the screen, ECO Mode turns off, and the brewer will heat to set temperature.
It takes approximately 7-15 minutes to return from 60°C/170°F to factory default 93°C/200°F
All FETCO commercial hot beverage equipment have well insulated hot water tanks and
have engineered mechanical features to limit energy consumption
.
Effective construction and insulation increases equipment life and lowers building HVAC costs.
FETCO hot beverage equipment have the best energy savings of all major suppliers.
X
X
T
T
S
S
™
™
E
E
X
X
T
T
R
R
A
A
C
C
T
T
O
O
R
R
T
T
O
O
U
U
C
C
H
H
S
S
C
C
R
R
E
E
E
E
N
N
CBS_2100XTS
■
ECO
Heating
Filling
89
°C
GENERAL
Programming Items
Factory set Default
Programming Range (display)
Notes
Tank Temp.
200°F
200 °F
|______________[]___|
170 207
Chart to correct for
high altitude below
Brew at Temp.
“
OFF” allows
brewing at any
temperature.
“ON”
ON
|________[]_______|
OFF ON AUTO
SEE NOTE BELOW!
Units of Meas.
• Temperature
°C or °F
°F
|___[]____________|
°F °C
[Switchable Units]
• Volume
Gallons [Liters]
Gallons
|___[]____________|
Gallons Liters
[Switchable Units]
ECO Mode
Energy Saving
Mode
OFF
ECO Mode
_______________[]_____
ON OFF
If Selected: Lowers hot
water tank temperature to
170
°F after 1 hour of
inactivity
Logo Timeout
0:30 mm:ss
0:30 mm:ss
|__[]___________|
0:15 5:00
Brew B. Sensor
NORMAL
(SEE WARNINGS)
NORMAL
|__[]____________|
NORMAL OVERRIDE
Factory or service use for
servicing. “NORMAL” is
recommended for safety.
Use Flowjet
NO
NO
____[]_______________
NO YES
Trims water handling
system for Flowjet
LLC Sensitivity*
Normal for most water
“HIGH” for R.O.
NORMAL
NORMAL
____[]______________
NORMAL HIGH
Liquid level control sensitivity.
High is for reverse osmosis
water or very pure water.
Most water has sufficent mineral content for proper brewer refill cycling. If refill is erratic, inspect all wiring and if
“ERROR CODE 107” displays, or if water is tested to be very pure (
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
0 0 205 212.0 96 100.0
500 152 205
211.0 96
99.5
1000 305 200
210.1 93
98.9
2000 610 200
208.1 93
97.8
2500 762 200
207.2 93
97.3
3000 914 200
206.2 93
96.8
3500 1067 197 205.3 92
96.3
4000 1219 195 204.3 91
95.7
4500 1372 194 203.4 90
95.2
5000 1524 194 202.4 90
94.7
5500 1676 193 201.5 89
94.2
6000 1829 192 200.6 89
93.6
6500 1981 191 199.6 88
93.1
7000 2134 190 198.7 87
92.6
7500 2286 188 197.8 86
92.1
8000 2438 187 196.9 86
91.6
8500 2591 185 196.0 85
91.1
X
X
T
T
S
S
™
™
E
E
X
X
T
T
R
R
A
A
C
C
T
T
O
O
R
R
T
T
O
O
U
U
C
C
H
H
S
S
C
C
R
R
E
E
E
E
N
N
CBS 2100
■
Ready
Heating
Filling
Tank Temp
92
°C
Regular 1
|■| 3:00
6:00
Regular 2
|■| 3:00
6:00
Decaf 1
|■| 3:00
6:00
Decaf 2
|■| 3:00
6:00
STOP
INFO
92°C
BREW AT TEMPERATURE DEFINITONS
--------------------------------------------------------------------------------
BREW AT TEMP: “
ON
”
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
“BREW START” Batch Section Buttons will not be accessible
until tank temperature is at set point.
The “BREW START” screens with the Batch Section Buttons
become accessible when hot water tank is at the selected
temperature. A screen (example to the right) will display showing
“BREW AT TEMP” is selected. Æ
--------------------------------------------------------------------------------
BREW AT TEMP: AUTO USER SELECTABLE
“BREW START” will pause if the hot water tank is not at the
selected temperature—and automatically start when it is at the
set temperature.
If the temperature is too low, the brewer will wait until the proper
temperature is reached. A screen (example to the right) will
display showing a thermometer icon and the tank temperatureÆ.
IMPORTANT: ALWAYS have dispenser(s) under the brewer
when in the BREW AT TEMP mode
----------------------------------------------------------------------------------------------------------
BREW AT TEMP:
OFF
USER SELECTABLE (Not recommended)
Allows brewing at any temperature above 170°F/77°C.
May NOT apply for two sided brewer if one side is in brew cycle