Fetco CBS-71A User Manual - page 3
3
Electrical Configuration and Brewing Efficiency
CBS-71A
&
AC
6.0 gallons per batch
Heater
Voltage
Maximum
Batches per Hour (max 5)
Model
Configuration
Connection
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
CBS-71A (-1)
3 X 5 KW
120/208
3 ph.
4 + ground
11.5
33.0
3.0
5.0
120/220
3 ph.
4 + ground
13.3
36.0
3.3
5.0
120/240
3 ph.
4 + ground
15.2
37.9
3.6
5.0
CBS-71A (-2)
3 X 10 KW
120/208
3 ph.
4 + ground
22.7
64.3
4.5
5.0
120/220
3 ph.
4 + ground
26.3
70.3
4.8
5.0
120/240
3 ph.
4 + ground
30.2
74.0
5.0
5.0
CBS-71A (-3)
3 X 10 KW
120/480
3 ph.
4 + ground
30.2
37.9
5.0
5.0
Batches per hour based on 7 minute
brew time, with no bypass
A and AC versions are actually identical units. The only difference is the stand or counter upon which the unit is
placed.
CBS-72A & AC
6.0 gallons per batch
Heater
Voltage
Maximum
Batches per Hour (max10)
Model
Configuration
Connection
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
CBS-72A (-1)
3 X 5 KW
120/208
3 ph.
4 + ground
11.6
33.7
4.7
10.0
with power
on each side
120/220
3 ph.
4 + ground
13.4
36.7
5.4
10.0
management
120/240
3 ph.
4 + ground
15.3
38.6
6.2
10.0
CBS-72A (-2)
3 X 5 KW
120/208
3 ph.
4 + ground
22.8
65.0
6.0
10.0
without power
on each side
120/220
3 ph.
4 + ground
26.4
71.0
6.6
10.0
management
120/240
3 ph.
4 + ground
30.3
74.7
7.2
10.0
CBS-72A (-3)
3 X 10 KW
120/208
3 ph.
4 + ground
22.8
65.0
9.3
10.0
with power
on each side
120/220
3 ph.
4 + ground
26.4
71.0
10.0
10.0
management
120/240
3 ph.
4 + ground
30.3
74.7
10.0
10.0
CBS-72A (-4)
3 X 10 KW
120/480
3 ph.
3 + ground
30.3
37.9
10.0
10.0
with power
on each side
(plus 120V
management
cord & plug)
CBS-72A (-5)
3 X 10 KW
120/480
3 ph.
3 + ground
60.3
74.7
10.0
10.0
without power
on each side
(plus 120V
management
cord & plug)
Batches per hour based on 7 minute
brew time, with no bypass
Each CBS-72 is actually two separate brewers in one body. Each side has a separate water tank and 3 heaters.
The power management feature allows only one side of the brewer to heat at any given time, which limits the total
amperage required for operation.
A and AC versions are actually identical units. The only difference is the stand or counter upon which the unit is
placed.