FHF Intelly Com Operating Manual

Manual is about: Weatherproof intercom station

Summary of Intelly Com

  • Page 1

    Weatherproof intercom station fhf ba 5228 07/14 operating manual.

  • Page 2

    2 / 18 operating manual - intellycom notes please read the operating manual carefully before installing the device. Texts and illustrations have been compiled and software created with the utmost care, however errors cannot be completely ruled out. This documentation is therefore supplied under excl...

  • Page 3: With Casing

    3 / 18 intercom station intellycom with casing loudspeaker microphone loop current indicator hook switch key.

  • Page 4: Built-In Unit

    4 / 18 intercom station intellycom built-in unit assembly cut-out thread m4 or Ø 4.3 mm.

  • Page 5

    5 / 18 connection opening the intercom station to gain access to the circuit board or the tamper alarm switch, unfasten the four screws in the front panel. Attention: before opening or dismounting the device it has to be separated from all voltage supply. Concluding notes ce (cable entry) m20 x 1.5 ...

  • Page 6

    6 / 18 relay contact output the intercom station board comprises a relay contact which can be activated from a remote telephone or telephone system. This relay can control for example electric door entry mechanism, signaling and other electrical devices. The voltage at the relay contact terminals sh...

  • Page 7

    7 / 18 operation making a call press the on/off button. The loop current indicator light blinks to indicate that a connection is being made, and changes to the continuous “on” state, when the receiving party answers the call. To converse with your respondent, speak in the direction of the intercom s...

  • Page 8

    8 / 18 programming the intercom station intellycom is designed to be programmed remotely over the telephone line. Programming is carried out using sequences keyed from a telephone, when connected to the intellycom to be programmed. Remote programming codes are split into two classes class 0 and clas...

  • Page 9

    9 / 18 *101disablebusy* set up option "disable in case of busy tone" disablebusy=0 disable in case of busy tone activated disablebusy=1 disable in case of busy tone deactivated delivery condition: disablebusy=0 disable in case of busy tone activated *102ringback* set up option "ring back schema" rin...

  • Page 10

    10 / 18 *142duplex_profile* set up duplex profile of voice communication duplex_profile=0-4 (full duplex -semi-duplex) delivery condition: duplex_profile=0 full - duplex remark: in case of inappropriate electrical and/or acoustic installation conditions co-coupling effects (whistler) may occur. In t...

  • Page 11

    11 / 18 *3000*accesscode* access code accesscode=0000-9999 except: 0600, 0990 and actual relaycode factory setting: accesscode=1234 *32t_button_pressed_ before_onhook* duration for which button must be pressed continuously for clear down to take place t_button_pressed_ before_onhook=05-99 *0.1 secon...

  • Page 12

    12 / 18 *5005* telephone number* program memory m5 factory setting: empty note: number chaining ends with memory m4 if memory m5 is empty. M5 is cleared with *5005** *5006* telephone number* program memory m6 factory setting: empty note: number chaining ends with memory m5 if memory m6 is empty. M6 ...

  • Page 13

    13 / 18 defining call procedures to define a call from the speed dial telephone number list you can define this call scenario by programming a maximum of 8 desired telephone numbers in the number list memory m1-m8. After pressing the on/off button, the station then attempts to connect to the program...

  • Page 14

    14 / 18 *2015* set minimum ringing duration to 15 sec, for example, to define how long intellycom should wait for the line dialed to the private branch exchange before it considers the connection failed and shuts off. Set the minimum ringing duration to “unending” by entering *2000*, if you want to ...

  • Page 15

    15 / 18 to define manual call acceptance you can define this call acceptance scenario by setting the programmed ring/signal counter *11xx* (3) to the value “99”. Incoming calls will then be acoustically 1) and optically signaled, and only accepted when the on/off button is pressed. Example: #1234# r...

  • Page 16

    16 / 18 you can manually stop the muting function by a short activation of the activation button and/or by selecting that intellycom ring back schema, which is able to distinguish earliest language and ring back tones. A reliable identification of the call begin cannot be guaranteed with none of the...

  • Page 17

    17 / 18 connection information input terminal voltage 24 v dc to 66 v dc from the telephone connection power supply current 28 ma dc to 100 ma dc call signal voltage 35 v ac to 90 v ac (23…54 hz) call signal impedance larger 5.5 kw at 25 hz and 30…90 v ac larger 4.0 kw at 50 hz and 30…90 v ac dialli...

  • Page 18

    Subject to alterations or errors fhf funke + huster fernsig gmbh gewerbeallee 15-19 · d-45478 mülheim an der ruhr phone +49 / 208 / 82 68-0 · fax +49 / 208 / 82 68-286 http://www.Fhf.De · e-mail: info@fhf.De.