Fiamma BP-L series Use and maintenance manual - page 23
FUNCTIONING OF BOILER ELEKTRA WITH REMOTE CONTROL
The actuation of heating mode takes place after an heating request from remote control
(value of heating setpoint calculated by remote control higher than heating setpoint set by
the user on remote control divided by two) and in the winter mode status.
CONTROL PANEL IN USER MODE
The pressure of one key/two keys activates the backlighting of LCD display.
KEY
FUNCTION
J5
Disabled in Opentherm mode
J6
Disabled in Opentherm mode
J7
Unlock error of safety thermostat
J4
Disabled in Opentherm mode
J2
Disabled in Opentherm mode
J3
Disabled in Opentherm mode
J5 + J6 Enabling of Eco/Comfort function
23
Parameters Table
FUNCTION N°
def. RANGE
EXTERNAL PROBE ENABLING
1
0
0 – 1
BUILDING LEAKAGE COEFFICIENT
2
35
5 – 35 °C
SANITARY POST CIRCULATION
3
15
1 – 180 sec
HEATING POST CIRCULATION
4
30
1 – 180 sec
HEATING EXCHANGER CIRCUL. START
5
0
0 – 240 sec
RANGE OF SETPOINT ADJUSTABLE BY MEANS OF REMOTE CONTROL
Interval of temperature setting with high temperature system
(JP7 = 0)
30 °C
÷
75 °C - step 1°C
Pre-set value: 60 °C
Interval of temperature setting with low temperature system
(JP7 = 1)
15 °C
÷
40 °C - step 1°C
Pre-set value: 30 °C
Interval of tank temperature setting
30 °C
÷
65°C - step 1°C
Pre-set value: 60 °C
It also enabled the relay which controls the valve opening area managed by Enchrono/Kronos.
HOT SANITARY WATER MODE
(if only
JP8 = 0)
The electric card of Elektra operates in the same way described previously.
The desired setpoint
is set by the user on the remote control.
Through the Enchrono OT1/OT2 you can enable the ECO/COMFORT by pressing
P
. When
the ECO function is active, the temperature of sanitary and the symbol
H
is the alternating
temperature. In the COMFORT mode, the temperature of the hot water circuit appears fixed
only when there is a request by the micro sanitary.
MIN. IGNITION TEMPER. CIRCULATOR
6
3
0
0 – 50 °C
DELIVERY DIFFERENTIAL OF SANITARY
7
1
5
0 – 20 °C