FOXSECUR Thinline Series User Manual - page 2
S
S
S
On Steady
AC power is good.
Pulsing
AC power is off.
On Steady
Battery power is good.
Pulsing
Battery power is low.
Open Lock
The system is completely disarmed.
Closed Lock
Some or all areas are armed.
See System Displays A, H, P or S.
Closed Lock/Instant
Some or all areas armed Instant.
See Arming the System.
Door or window perimeter zone(s) are selected for monitor.
See Door Chime.
All burglary protection zones are normal and system is ready
to arm.
System is not ready to arm due to a burglary zone in a faulted
state such as an open door. See Zone Status.
Pulsing
A system message being sent to your monitoring
station failed to transmit over the telephone line.
On Steady
Your system is programmed for Network
(Internet) communication and functioning properly.
Pulsing
Network (Internet) communication interrupted.
A burglary alarm has occurred. The zone number is shown in
the 3-character display.
A fire alarm has occurred. The zone number is shown in the
3-character display.
TEST ICONS
AC Power
Battery
Armed
Status
Door
Chime
Thumbs
Up
Thumbs
Down
Telephone
Handset
Network
Connection
Burglar
Flame
CANCEL
BYPASS EXTEND VERIFY
ARMING THE SYSTEM
ARMING WITH A CODE OR PROXIMITY CREDENTIAL
While the Thumbs Up icon is displaying, enter your user code or present a proximity credential
to begin the exit countdown. Arming is delayed until the end of the countdown. Pressing the
INST key during the exit countdown immediately arms the system and entry/exit delays. An
alarm would immediately occur should an exit door be opened.
ARMING WITH SHORTCUT KEYS
While the Thumbs Up icon is displaying, press and hold the ALL, HOME, PERIM or SLEEP
key for two seconds to arm your system.
ALL 1
ALL
arms the entire system.
HOME 3
HOME
or
PERIM
arms the Perimeter zones leaving the Interior disarmed.
PERIM 6
SLEEP 7
SLEEP
(optional)
arms the Perimeter and Interior zones leaving the sleeping area disarmed.
ARMING WITH FAULTED ZONES (
THUMBS
DOWN
)
BYPASS
Thumbs down displays and the keypad sounds four short beeps when a
burglary zone is faulted while arming the system. The zone number is shown in the
3-character display. If the problem is simply an open door or window, press the Back
Arrow key, correct the problem, and try arming again. If the problem cannot be corrected,
press the Select Key under BYPASS to go ahead and arm the system. A zone remains
bypassed until the system is disarmed. If no selection is made, the system will automati-
cally force arm any faulted burglary zones without bypassing.
DISARMING THE SYSTEM
DISARMING WITH A CODE OF PROXIMITY CREDENTIAL
When the Armed (Lock) icon is displaying, enter your user code or present a proximity
credential to disarm the entire system.
DISARMING DURING AN ALARM
Enter your user code or present a proximity credential to silence the siren leaving the
system armed. After a user code is entered to silence the siren, CANCEL/VERIFY displays
allowing you time to investigate a burglary alarm prior to disarming the system.
CANCEL
If a valid alarm has not occurred, choosing CANCEL disarms the system and
sends a Cancel or Abort message to the Central Station.
VERIFY
If the alarm is valid, choosing VERIFY sends a Verify message to the Central
Station. The system remains armed to provide continued intrusion detection.
CHIME 7
EXIT 8
OUTPUT 0
DOOR
CHIME
EASY
EXIT
+
[
your code
]
+
[
output number
]
ALERT OPERATIONS
Steady Tone
A trouble condition on the system. A zone number may be
displayed. Pressing any key silences the steady alert tone.
1 One-Second Beep
Indicates the successful completion of a function.
4 Short Beeps
When an incorrect key or function is entered.
1 Short Beep
Each time a key is pressed.
PANIC KEY OPERATION
Your keypad may be programmed to send a Panic, Emergency, or Fire report to
your monitoring station. If this option is programmed for your keypad, icons
appear below the top row Select keys. Press and hold the two Select keys
adjacent to the desired icon for 2 seconds and a beep from the keypad is heard.
The report is sent to your monitoring station.
EXTENDING THE SCHEDULE
EXTEND
Your system may be programmed with a schedule to identify
authorized disarmed periods. This option displays and a steady tone sounds
when the authorized disarmed period is about to expire. Press the Select key
under EXTEND and enter your user code to extend the schedule for an additional
hour. If more than one hour is needed, after entering a user code, press the
number of hours between one (1) and the maximum nine (9).
SYSTEM FUNCTIONS
You can enable monitor for all Perimeter zones in the system to sound
a doorbell chime at the keypad anytime a zone is opened. Press and
hold the CHIME (5) key for two seconds. The Door icon will display
and the doorbell chime sounds. Pressing the CHIME key again for two
seconds turns off this function.
This function allows you to exit your home while the system is armed.
Press and hold the EXIT (8) key until the exit countdown begins to
display and then exit. The system automatically arms again after the
countdown completes.
Your system may have lights or other devices connected to outputs
that you can turn on or off using the keypad. Press and hold the
OUTPUT (0) key until the keypad beeps. Enter your user code and then
the 2-digit number of the output including any leading zero such as
01. This changes the output from off to on or vise versa.
Top Row Select Keys
Police
Emergency
Fire
OUTPUTS
ON/OFF