ASSEMBLY INSTRUCTIONS
• Remove blower unit from box and inspect for
shipping damage.
• Position unit to rest on front cover.
• Remove wheel nuts and wheels with a 15/16
wrench.
Handle Assembly (Refer to figure 1).
1. Insert lower handle (B) into upper handle
(A) making sure that throttle guides are
both in line.
2. Insert lower handle (C) into upper handle
(A).
3. Install handle plate using four 5/16 x 1 1/4
bolts washers and lock nuts, ensuring that
all bolts are properly tightened.
• Install handle assembly to the blower frame
using two 5/16 x 1 1/2 bolts, washers and
lock nuts, and two 5/16 x 1 1/4 bolt, washer
and lock nuts.
• Ensure that all bolts are properly tightened.
• Reinstall wheels. Ensure that all bolts are
properly tightened.
• Install throttle cable using two #10 screws,
washers and lock nuts.
• Fill up crank case with proper engine oil.
Refer to engine manufacturing manual.
• Ensure that all nuts, screws and bolts,
installed are properly tightened.
• Check wheel for proper inflation - 15-20 PSI
all models. Do not over inflate.
• Start unit.
————— CAUTION: —————
Check Governed Speed
PB-5.5BS 3300 R.P.M. (maximum)
PB-8.5KY 3600 R.P.M. (maximum)
PB-10IP
3600 R.P.M. (maximum)
PB-9HD
3600 R.P.M. (maximum)
PB-13HD
3300 R.P.M. (maximum)
PB-16VG
3600 R.P.M. (maximum)
PB-13KY
3300 R.P.M. (maximum)
Handle Assembly
FIGURE 1
BE SURE BLOWER IS FULLY ASSEMBLED!
Never operate blower without all guards and deflectors in place.