Always respect the following implicitly:
The operation of kitchens and kitchen exhaust air equipment must only be
performed with FRANKE - aerosol filters, see Figure 2a, page 5 inserted in the
fume extraction hood.
The UVC system must be switched off before the filters are removed from the
hood!
Attention:
Attention: In the absence of protection, UVC light is hazardous to humans (to
eyes and skin).
Before opening the equipment, which also includes removing the aerosol
filters (FRANKE filters, see Figure 2a, page 5), the UVC system must in all
cases be switched off manually via the switch (see Figure 2, "C").
!
Read these instructions through carefully and retain them for future reference.
i
!
Attention!
Ozone is hazardous to the respiratory tract.
Therefore, affix warning signs to the exhaust air appliance, inspection
aperture and exhaust air outlets in the roof area, which refer to the fact that
the exhaust air contains ozone.
!
Warning!
If the blue UVC light becomes visible from the outside, the UVC system must be
switched off immediately. Please inform your service company.
!
Independent troubleshooting / repair work and intervention into the equipment
invalidates the warranty in all cases.
!
Warning!
If a protection tube or UVC lamp breaks, you must follow the instructions in
Chapter 4.1.
!
Warning !
The differential pressure monitors are equipped with a seal. If this
seal is broken, all warranties and liabilities are void.