G-Lab Guitar System Controller User Manual - page 11
9
In case of necessity of returning without saving while in the point c) should be pressed LOOP or
SWITCH button.
Indicator No.
MIDI channel No.
1
2
3
4
5
O*
1
O*
2
O
3
O
4
O
5
O
O
6
O
O
7
O
O
8
O
O
9
O
O
O
10
O
O
O
11
O
O
O
12
O
O
O
O
13
O
O
O
O
14
O
O
O
O
O
15
O – indicator lit
16
*
– factory settings are: channel No. 1 for the first device and channel No. 2 for the
second one
Second MIDI device control
The GSC enables to control two MIDI devices if one of them is equipped with THRU output. The
program No. is assigned separately for each preset and for each device.
To connect the second MIDI device:
- enable the second MIDI device control at the SWITCH button settings,
- set the second MIDI device channel No.; the procedure is identical with the setting of the first
device channel, the only difference is that just after pressing MIDI button in accordance with the
previous point b) the DEF button should be pressed (banks indicators will start to blink slowly),
- set the second MIDI device’s program No. for each preset; the procedure is identical with the
setting of the first MIDI device, the only difference is that just after pressing MIDI button in
accordance with the previous point e) the DEF button should be pressed (MIDI and preset
indicators will start to blink slowly).
To control two MIDI devices the receiving devices can not be set for reception from any channel
(OMNI).
Effects to LOOP1 to LOOP4 loops connecting
At adequate LOOP1 to LOOP4 loops each effect pedal (stomp box) input (IN) should be connected
to SEND output of the GSC and each its output (OUT) should be connected to RETURN output of GSC.
Effects’ mains switches should be permanently switched on.
The stomp boxes can be supplied by 9V cables connected to the GSC.
REMARK:
Before connecting please check if voltage and polarisation of stomp box power supply connector is
identical with the GSC OUT 9V DC output.
It is possible to connected serially connected effects to a loop with possibility to switch them on
and off by their own main switches. GSC enables to supply power to more effects than OUT 9V DC
outputs providing that stomp boxes are connected to them on short (up to 0.5 m) cables and power supply
overload indicator (9V OVERLOAD) is not lit. To supply with power more stomp boxes should be bought
(or made) proper cable distributing power to more stomp boxes from one output.