Gabarron MATTIRA MAC15 Installation Instructions And User Manual - page 33
33
11 TECHNICAL DATA
MAC15
Frequency Hz
50
Connection 3x400V+N~
Output limited to 15kW; Maximum intensity
A
21.7
Output limited to 13kW; Maximum intensity
A
21.7
Output limited to 12kW; Maximum intensity
A
21.7
Output limited to 11kW; Maximum intensity
A
21.7
Output limited to 10kW; Maximum intensity
A
21.7
Output limited to 9kW; Maximum intensity
A
13.0
Output limited to 8kW; Maximum intensity
A
13.0
Output limited to 7kW; Maximum intensity
A
13.0
Output limited to 6kW; Maximum intensity
A
13.0
Output limited to 5kW; Maximum intensity
A
13.0
Output limited to 4kW; Maximum intensity
A
13.0
Output limited to 3kW; Maximum intensity
A
13.0
Connection 230V~ single phase
1
Nominal maximum intensity 15kW
A
65.2
1
Maximum converted intensity at 13kW
A
56.5
1
Maximum converted intensity at 12kW
A
52.2
Maximum converted intensity at 11kW
A
47.8
Maximum converted intensity at 10kW
A
43.5
Maximum converted intensity at 9kW
A
39.1
Maximum converted intensity at 8kW
A
34.8
Maximum converted intensity at 7kW
A
30.4
Maximum converted intensity at 6kW
A
26.1
Maximum converted intensity at 5kW
A
21.7
Maximum converted intensity at 4kW
A
17.4
Maximum converted intensity at 3kW
A
13.0
DHW available time with 15kW
min
5’49”
DHW available time with 13kW min
6’42”
DHW available time with 12kW min
7’16”
DHW available time with 11kW min
7’56”
DHW available time with 10kW min
8’43”
DHW available time with 9kW min
9’41”
DHW available time with 8kW min
10’54”
DHW available time with 7kW min
12’27”
DHW available time with 6kW min
14’32”
DHW available time with 5kW min
17’26”
DHW available time with 4kW min
21’48”
DHW available time with 3kW min
29’04”
DHW available time with 2kW min
43’36”
Weight
kg
72
Insulated steel heater header
50 L stainless steel insulated DHW store
No CFC
Stainless steel plated resistance elements INCOLOY800
DHW
Stainless steel plated resistance elements INCOLOY800
Heating
6 litre expansion vessel
DHW 3 litre expansion vessel
Electronic regulation of heater modulation
Electronic regulation DHW
Digital display
0-4 bar
pressure gauge
Accelerator pump
Automatic purge
TRIACS silent power switches
Heating flow detector
100°C heating temperature limiter
80°C DHW temperature limiter
3 bar
central heating relief valve
7 bar
DHW Pressure and Temperature relief valve
DHW retention valve
Ambient thermostat intake
Anti-electrolysis DHW hoses.
Sound power level (L
WA
) dB
36
included
1
using connecting links included