Gaggenau AI 200 Operating And Assembly Instructions Manual

Summary of AI 200

  • Page 1

    Operating and assembly instructions ai 200 extractor hood.

  • Page 3

    1 ai 200 preface safety notes page 3 1. Important notes page 4-5 1.1 for your safety page 4 1.2 operating for the first time page 5 1.3 about use page 5 2. Features page 6 3. Operation page 7-9 4. Cleaning and care page 10-1 1 5. Maintenance page 12 6. Assembly instructions page 13-18 6.1 technical ...

  • Page 4

    2 preface with your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light....

  • Page 5

    W arning - to reduce the risk of fire, electric shock, or injury to persons, observe the following: a.) use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.) before servicing or cleaning unit, switch power off at service panel and lock th...

  • Page 6

    4 1.1 f or your safety – damaged appliances must not be operated. – the appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – connec...

  • Page 7

    1.2 operating for the first time before operating the appliance for the first time, please pay attention to the following notes: – the appliance must be installed and connected by a specialist before it is operated for the first time. – conscientiously read through the operating and assembly instruc...

  • Page 8

    6 2. Features 1 v entilation duct 2 control panel 3 grease filters 4 lighting installation accessories for exhaust air mode stainless steel-design ventilation duct: ad 010-016 for ceiling heights of 7 ´´ 4 ´ ´ - 7 ´´ 11 ´ ´ ad 010-026 for ceiling heights of 7 ´´ 11 ´ ´ - 9 ´´ ad 010-036 for ceiling ...

  • Page 9

    7 3. Operation after they have been pressed, all functions selection keys except 0 (“motor off”) are backlit in green. Light the lighting can be switched on or off, regardless of whether the extractor hood is in operation, by pressing the key (see fig. 4). When you briefly press the key, the lightin...

  • Page 10

    8 the int key for the intensive level should be pressed when browning and frying in an open pan (see fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the int key while the hood is running at fan leve...

  • Page 11

    9 special functions: intensive time: you can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the int key and the 1, 2 or 3 key and you can store this setting (see fig. 9). When delivered, the appliance is set to five minutes, i.E. The combination of the int key ...

  • Page 12

    10 cleaning the grease filters the grease filter saturation display f flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not...

  • Page 13

    11 cleaning the extractor hood clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either. Clean the stainless-steel extractor hood with stainless steel cleaner...

  • Page 14

    The appliance must be disconnected from the power supply during all repair work. If the appliance does not function correctly , check the fuses first. If the power supply is functioning correctly, but your appliance still does not work, please contact your gaggenau dealer who will provide you with t...

  • Page 15

    13 w arning - to reduce the risk of fire, electric shock, or injury to persons, observe the following: a.) installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. B.) sufficient air is neede...

  • Page 16

    14 6.2 installation the applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. This hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop. The hood can be used in the exhau...

  • Page 17

    15 flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire b1 in accordance with din 4102 can be used. Exhaust air pipes should have a nominal diameter of 6 ´ ´ / 150 mm. P ay particular attention to ensuring that – the exhaust air ducts ...

  • Page 18

    16 installation of the extractor hood: 1. Using the drilling template mark the position of the screws on the ceiling. 2. Drill 4 holes Ø 8 mm for the wall plugs. Push the plugs flush with the ceiling (fig. 19). 3. T urn two screws to a 10 mm gap. Both screws are placed in a position, in which at a l...

  • Page 19

    5. Hang the support frame with the two key-holes to the two screws in the ceiling and attach it with all 4 screws to the ceiling. Circulating air mode only : assemble the circulating air switch module and fix it to support frame (fig. 22 and 23). Cut the flexible air pipe to the required length and ...

  • Page 20

    18 7. Slide the extractor hood into the on the side of the support frame (note: take care not to trap the mains connecting cable) and immediately secure the hood with 4 screws (fig. 25). 8. Screw the cover plate back on the rear of the support frame. The cover plate is important for the stability of...

  • Page 24

    Gaggenau 780 dedham street canton, ma 02021 usa telephone: 877.4gaggenau fax: 714.901.5360 www.Gaggenau-usa.Com gaggenau hausgeräte gmbh carl-wery-straße 34 81739 münchen germany www.Gaggenau.Com 9000232642 eb 8701 enus.