    Operating and assembly instructions ai 200 ai 201 ai 202 ai 203 extractor hood.

  • Page 3

    1 ai 200 ai 201 ai 202 ai 203 preface 1. Important notes page 3-4 1.1 for your safety page 3 1.2 operating for the first time page 4 1.3 about use page 4 2. Features page 5 3. Operation page 6-8 4. Cleaning and care page 9-10 5. Maintenance page 1 1 6. Assembly instructions page 12-17 6.1 technical ...

  • Page 4

    2 preface with your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light....

  • Page 5

    1.1 f or your safety – damaged appliances must not be operated. – the appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – connecti...

  • Page 6

    1.2 operating for the first time before operating the appliance for the first time, please pay attention to the following notes: – the appliance must be installed and connected by a specialist before it is operated for the first time. – conscientiously read through the operating and assembly instruc...

  • Page 7

    5 2. Features 1 v entilation duct 2 control panel 3 grease filters 4 lighting installation accessories for exhaust air mode stainless steel-design ventilation duct: ad 010-016 for ceiling heights of 2.24 - 2.42 m ad 010-026 for ceiling heights of 2.42 - 2.74 m ad 010-036 for ceiling heights of 2.74 ...

  • Page 8

    6 3. Operation after they have been pressed, all functions selection keys except 0 (“motor off”) are backlit in green. Light the lighting can be switched on or off, regardless of whether the extractor hood is in operation, by pressing the key (see fig. 4). When you briefly press the key, the lightin...

  • Page 9

    7 the int key for the intensive level should be pressed when browning and frying in an open pan (see fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the int key while the hood is running at fan leve...

  • Page 10

    8 special functions: intensive time: you can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the int key and the 1, 2 or 3 key and you can store this setting (see fig. 9). When delivered, the appliance is set to five minutes, i.E. The combination of the int key ...

  • Page 11

    9 cleaning the grease filters the grease filter saturation display f flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not ...

  • Page 12

    Cleaning the extractor hood clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either. Clean the stainless-steel extractor hood (ai 200/ai 202) with stainless ...

  • Page 13

    Disconnect the appliance from the mains before carrying out any repairs. In the event of malfunctions, first of all check the household fuses. If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or gaggenau aft...

  • Page 14

    12 6.1 t echnical data ai 200: max. Weight depending on version 45 kg dimensions 998 x 648 mm ai 201: max. Weight depending on version 45 kg dimensions 998 x 648 mm ai 202: max. Weight depending on version 43 kg dimensions 998 x 648 mm ai 203: max. Weight depending on version 43 kg dimensions 998 x ...

  • Page 15

    13 flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire b1 in accordance with din 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. P ay particular attention to ensuring that – the exhaust air ducts and pipe...

  • Page 16

    T o use above gas cooker / gas hob important: do not use all burners on the highest setting simultaneously over a longer period of time (max. 15 minutes). This will pose a risk of burns when touching the hot appliance exterior or parts of the extractor hood may become damaged. Switch the extractor h...

  • Page 17

    15 installation of the extractor hood: 1. Using the drilling template mark the position of the screws on the ceiling. 2. Drill 4 holes Ø 8 mm for the wall plugs. Push the plugs flush with the ceiling (fig. 19). 3. T urn two screws to a 10 mm gap. Both screws are placed in a position, in which at a l...

  • Page 18

    5. Hang the support frame with the two key-holes to the two screws in the ceiling and attach it with all 4 screws to the ceiling. Circulating air mode only : assemble the circulating air switch module and fix it to support frame (fig. 22 and 23). Cut the flexible air pipe to the required length and ...

  • Page 19

    7. Slide the extractor hood into the on the side of the support frame (note: take care not to trap the mains connecting cable) and immediately secure the hood with 4 screws (fig. 25). 8. Screw the cover plate back on the rear of the support frame. The cover plate is important for the stability of th...

  • Page 20

    Gaggenau hausgeräte gmbh carl-wery-straße 34 d - 81739 münchen www.Gaggenau.Com 9000232720 eb 8701 en.