5. Route the freshwater hose to the stop valve.
Note!
Do not run over or kink the freshwater hose with
AquaStop valve when you are routing it.
Risk of leaks and water damage.
6. Connect the AquaStop valve to the stop valve.
7. Open the stop valve and the main water cock.
8. Check the connection point at the stop valve for
leaks.
9. Route the outlet hose to the outlet connection
parallel with the floor. Route the outlet hose in such
a way that it cannot be run over or kinked when the
appliance is moved into the niche.
10. Route the outlet hose upwards at a right angle to the
outlet connection and connect it.
5.
Connecting the appliance to the
mains
The freshwater hose and outlet hose must be
connected before the appliance is connected to the
mains.
1. Route the power cord to the socket. Route the
power cord in such a way that it cannot be run over
or trapped when the appliance is moved into the
niche.
2. Switch off the master switch.
3. Plug the power cord into the mains.
Following installation, there must be a minimum waiting
period of ½ hour before the master switch is switched
on.
The oil contained in the compressor may have been
displaced into the refrigeration system during transport.