18
8.1 Technical data
Total rating:
2.3 kW
Fuse:
10 Ampère
Appliance dimensions:
288 x 510 x 198.5 mm
8.2 Important notes on assembly
The installing techician
is responsible for
perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with
reference to the operating instructions. He must
draw the user's attention as to how to isolate the
appliance from the mains whenever necessary.
Any damage
caused by failure to observe these
instructions cannot be recognised.
If, after installation,
not all poles of the appliance
can be isolated from the mains by removing a plug,
an isolating device with a contact gap of at least
3 mm (e.g. a fuse) must be permanently installed.
Note:
do not install the appliance directly next to a
steam cooker!
The deep fryer
may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
Pay attention to the
“Important notes"
(Chapter 1).
There must be
a door in the base cabinet
so as to
enable you to operate the oil drain valve.
Technical modifications without notice.
Electrical connection
The appliance
must only be connected by an
authorised electrician
, paying attention to all
relevant regulations
The power rating for one deep fryer is 2.3 kW.
Pay attention to the data on the rating plate. The
appliance can be connected with a plug or it can
be connected permanently. The
mains connecting
cable
must at least correspond to the type H 07 RN-
F 3G1.5. You are advised to install an earthed
socket for 10 A or a junction box about 70 cm above
the floor space behind the appliance to that it is
also accessible after installtion of the appliance.
Connection type Y:
if damaged, the mains cable
must be replaced by a special mains connecting
cable. The mains connecting cable must only be
connected by the manufacturer or the
manufacturer's after-sales service.
8. Assembly instructions