Pub. 42004-404f gai-tronics corporation 400 e. Wyomissing ave. Mohnton, pa 19540 usa 610-777-1374 800-492-1212 fax: 610-796-5954 v isit www . Gai - tronics . Com for product literature and manuals g a i - t r o n i c s ® c o r p o r a t i o n a h u b b e l l c o m p a n y model 10959-207 and -208 ra...
Table of contents pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 date set up .............................................................................................................
P ub . 42004-404f gai-tronics corporation 400 e. Wyomissing ave. Mohnton, pa 19540 usa 610-777-1374 800-492-1212 fax: 610-796-5954 v isit www . Gai - tronics . Com for product literature and manuals g a i - t r o n i c s ® c o r p o r a t i o n a h u b b e l l c o m p a n y model 10959-207 and -208 ...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 2 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 options telephone access integration to page/party ® systems up to 40 general inputs and 40 general outputs routability to...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 3 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 optional telephone operation the telephone interface has multiple operational modes. The appropriate mode is configurable ...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 4 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 optional advance operation the page/party ® operation allows for the ami to play messages/alarms and connect phone calls t...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 5 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 installation power disconnect. The power cord is the main power disconnect for all units. Disjontion de l’alimentation. Le...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 6 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 field wiring figure 3. Back of rack with connections labeled digital outputs the terminal block labeled digital outputs pr...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 7 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 table 2. Digital output assignment metalwork label internal terminal pin-out function or act description gnd tb1-1 ground ...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 8 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 audio the terminal block labeled audio provides connections for audio inputs and outputs, and for local rs-485 data connec...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 9 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 power the terminal block labeled class 2 12 –24 vdc provides power connection for the ami. Table 6. Power assignment metal...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 10 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 settings and adjustments opening the unit if installed in a card rack, remove the four 10-32 ¾-inch screws holding the un...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 11 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 level adjustments display brightness r237 on the main pcba adjusts the brightness of the lcd display on the front of the ...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 12 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 table 8. Termination pcba jumper functions jumper output position function p1 tb3-5, 6 audio bus 1 1-2 600-ohm resistor c...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 13 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 date and time set up date set up push buttons on the front of the unit allows for date set up. Complete the following pro...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 14 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 operation once the compactflash ® is programmed and installed into the unit, the unit operates based on system inputs and...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 15 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 lcd display during operation the lcd uses various symbols to indicate ami activity. The vu meter indicates the volume of ...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 16 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 push-button operation the front panel push buttons allow for various control features including, play a message, stop a m...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 17 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 ami configuration tool (act) overview the audio messenger interface configuration tool (act) software is used to define a...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 18 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 outputs each output circuit must be enabled or disabled. If enabled, it must be programmed with several parameters such a...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 19 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 compactflash ® the compactflash ® memory card stores the system configuration, speech messages, and alarm tones. Formatti...
Pub. 42004-404f m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 20 of 20 f:\standard ioms - current release\42004 instr. Manuals\42004-404f.Docx 11/13 communications advance .....................................................................................................
(rev. 10/06) warranty equipment. Gai-tronics warrants for a period of one (1) year from the date of shipment, that any gai-tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and ...