Installation
WARNING
• Do not install this equipment in hazardous areas. Such installations may cause a safety hazard
and consequent injury or property damage.
• Do not disconnect equipment while energized.
The installation procedure for the Model 723-905 SmartSeries Remote Subset Amplifier is described
below. Use extra care not to damage the protruding latch wings of connector J2 located on the bottom
edge of the amplifier during installation.
1. Plug the amplifier connector J3 (located at the end of the pigtail cable on the amplifier) into the
mating connector of the Model 7245-005 Enclosure.
2. Plug the amplifier connector P1 (located on the rear of the amplifier) into the J1 connector of the
Model 7245-005 Enclosure.
3. Tighten the four screws in the corners of the amplifier. The recommended torque setting is 10 to 12
in-lbs. or 1.13 to 1.36 n-m.
Operation
The Model 723-905 SmartSeries Remote Subset Amplifier supports page, party, and auxiliary input
(optional) operations of the remote subset. Refer to the appropriate remote subset manual for all