Galanz AUF-48H58R520 Owner's manual

Manual is about: SPLIT AIR CONDITIONER FLOOR STANDING TYPE

Summary of AUF-48H58R520

  • Page 1

    Owner's manual split air conditioner floor standing type thank you for choosing an air conditioner. Please read this owner's manual carefully prior to using, keep it for further reference. Do not attempt to install, service or move the air conditioner by yourself. Incorrect behaviour may cause fire,...

  • Page 2: Contents

    1 contents name of the components 5 safety awareness 3 pre-repair check 18 guide to proper usage 15 operation of air conditioner 8 installation instructions 20 performance parameter 19 17 maintenance intelligent self diagnosis 26 contents 1 2 features of the air conditioners.

  • Page 3

    The super-thin cabinet, ivory tint color and cambered surface design all make the products look elegant and splendid. The large diameter centrifugal fan and foam wind tunnel designs greatly reduce the noise of the products. This makes the products possess a leading position in the air conditioning i...

  • Page 4

    Safe 3 the capacity of the power lines must be enough; the power lines must have circuit breakers and fuses. Otherwise the power lines might be overheated and cause fire. When the machines are working, do not cut off the power (turn off the power switch, for example). If you do not use the machine f...

  • Page 5

    4 do not put a finger, a rod or other objects into the air outlet/inlet grille. As the fan is running at a high speed, it will cause injury. Kids should pay more attention to this warning. It is important that your air-conditioner is firmly grounded. Inlets and outlets of indoor and outdoor units sh...

  • Page 6: Outdoor Unit

    5 outdoor unit name of the components air inlet connecting pipe drain hose drain opening air outlet note: we reserve the right to improve the appearance of air conditioner and the continuing improvement is subject to change without notice. Indoor unit up and down air vanes (up and down air flow with...

  • Page 7: Notice:

    6 notice: heat mode is not applied to c . Ool only type remote controller please aim the signal ejecting window of the remote controller at the signal receiving window of the indoor unit. Name of the components only electric-heat series contains electric heating . Mode press this button , the swing ...

  • Page 8: Notice

    7 name of the components 1 2 short reset piece with forceps. (short two reset pieces after changing the batteries. ) notice if the remote controller is out of running, please short two reset pieces and it will resume to normal working. The maximum distance for communication between the remote contro...

  • Page 9

    8 operation of air conditioner operation procedure-control under the remote controller press fan speed button, change the fan speed of indoor unit in the order of : sleep selection press sleep button, set sleep operation, and cancel when repressed. Run/stop press i/o button, start operation, and sto...

  • Page 10

    9 operation of air conditioner controller press the button, air conditioner start operation, and stop when repressed. The lighting lamp shows air conditioner in operation state. Run/stop button press the button, the deflector start swing, and cancel when repressed. The lighting lamp shows the mode c...

  • Page 11

    Operation of air conditioner 10 press the swing button ,swing light lighted , swing sign flashing , the left /right deflector starts swinging. D i r e c t i o n a l f a n operating the up/down deflector can adjust the up/down swing angle. In cool or dry mode, usually adjust the up/down deflector to ...

  • Page 12: Dehumidify  Operation

    11 operation of air conditioner stop: press “on/off”button. Press “on/off”button. Press“mode”button, setting “dry”mode. Press“swing”button, setting fan direction. C o o l i n g o p e r at i o n press “ ”“ ”buttons,setting temp. + - on/off timer temp swing timer sleep fan speed - mode + stop: press “...

  • Page 13

    12 h e at i n g o p e r at i o n ( o n l y a p p l y t o h e a t p u m p t y p e ) operation procedure-control under the controller in indoor unit press “on/off”button. Press“mode”button, setting “heat”mode. Press “ ”“ ”buttons,setting temp. + - stop: press “on/off”button. Press“fan speed”button, se...

  • Page 14: S L E E P M O D E

    Operation of air conditioner operation procedure-control under the controller in indoor unit 13 s l e e p m o d e stop: press “on/off”button. Press “on/off”button. Press“mode”button, setting “heat”mode. Press“fan speed”button, setting fan speed. Press“sleep”button, setting sleep mode. Press “ ”“ ”bu...

  • Page 15

    Electron lock elec- heat operation of air conditioner the remaining time display as picture displays, the machine will stop running after 4 hours. Timer off on running condition, the machine will stop when the time of setting reaches. Timer on on off condition, the machine will start running when th...

  • Page 16

    15 guide to proper usage set the room temperature to your suitable point during cooling, a difference of 5℃ between the indoor and outdoor temperature will suit you better. During cooling, increase of 1℃ will save energy by 10%. When cooling, keep away from sunshine during cooling, draw the curtains...

  • Page 17: For A Long Idle Period

    Off 3 switch off the air conditioner . Set the fan of the indoor unit going for 3 to 4 hours to dry out the inside thoroughly. (for cool only type, just set fan mode; for heat pump type, choose cool mode or heat mode and select the highest or lowest temperature.) operate the air conditioner 12 hours...

  • Page 18

    Maintenance 17 cleaning of the filter net if the machine has been operating for a long time, the filter shall be cleaned termly. It is better to clean the filter net biweekly. First remove the inlet grid, and then remove the air filter net. Clean the air filter net. It can be cleaned with the vacuum...

  • Page 19

    18 pre-repair check please check the following items before calling a repair person. And if you still need help, please contact with our designated service centre. The air conditioner does not operate at all. The cooling or heating effect is not good. The indoor fan stops during heating. (for heat p...

  • Page 20

    1900 2850 4.8 60 ipx4 t1 52 85 62 performance parameter outdoor heat pump type auf-48h58r520 1.The indicated noise parameter is measured in laboratories before leaving factory. 2.The rated cooling/heating capacity is tested under the following conditions: cooling operation heating operation indoor i...

  • Page 21: Mounting  Accessories

    Installation instructions selection of installation location a place avoiding direct sunshine and easy for condensate drain and easy for connecting with the outdoor unit. Keep at least 1m away from the tv radio and other home appliances and keep a far distance away from the fluorescent lamp. A place...

  • Page 22

    21 according to the position of soutache on the wall, select the proper way as the following: the machine can be directly fixed on the wall that must be solid enough. While installing the air exhaust pipe at top of the unit, please don't overlay the bolt hole for installing the air outlet pipe. (you...

  • Page 23

    22 above 100mm less than 100 sets above 1000mm above 200mm above 100mm multi-unit mounting 1 install side by side(if this method is used, the top side must be open. Meanwhile, please remove the bolts at the pipe side ) 2 install in tandem above 200mm above 500mm above 200mm above 200mm above 500mm a...

  • Page 24: Drain Pipe (Indoor Unit)

    14--17 30--35 30--35 6.35mm(1/4") 9.52mm(3/8") 12.7mm(1/2") 15.88mm(5/8") 73--78 60--90 60--90 30--60 30--60 23 installation of refrigerant pipeline and drain pipe (indoor unit) 1to remove the bottom panel, you should remove the fixing screws first and then pull the panel out. 2 remove the fixing sc...

  • Page 25: Connect Connecting Pipe

    Installation instructions 24 allowable length of the distribution pipe (one way) amount of fluorine to be filled (gram) indoor unit connection pipe liquid pipe stop valve gas pipe outdoor unit maintenance mouth refrigerant storage bottle operating valve of refrigerant storage bottle attention: 1 don...

  • Page 26: Signal Wires

    25 connection of power supply wires and signal wires outdoor unit 1 remove the self-tapping screws (3 pcs) fixing the electric box cover and take out the electric box. 2 loosen the fixing screw of the power terminal board and signal terminal board, then firmly fix the power wire and signal wire on t...

  • Page 27: Intelligent Self Diagnosis

    Intelligent self diagnosis intelligent self diagnosis 26 when electrify for the first time, the air conditioner will check the function automatically.If has some thing wrong, the system will d conditioner isplay the room temperature and the set temperature substitute to show the trouble of the air ....

  • Page 28

    Kl-d2(47)-520-r-e.