Galletti IWC32 Technical Manual

Manual is about: CASSETTE FAN COILS 2,6 kW - 9,1 kW

Summary of IWC32

  • Page 1

    Iwc cassette fan coils 2,6 kw - 9,1 kw technical manual en.

  • Page 2: Iwc

    Iwc 2 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 table of contents 1 constructive features .............................................................2 2 construction versions ............................................................2 3 air range .........

  • Page 3: Iwc

    Iwc 3 z y x all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 3 air range • fin inclination 45° • limit speed 0.2 m/s mode • heating in nominal conditions model iwc32-34 iwc42-44 iwc52 iwc62 iwc82 speed 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 air range z 1,7 3,0 3,...

  • Page 4: Iwc

    Iwc 4 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 4 ratings and technical data notes: 1 = water temperature 7/12°c, air temperature d.B. 27°c, w.B. 19°c, 47% humidity 2 = inlet water temperature 50°c, water flow rate same as in cooling mode, air inlet tempera...

  • Page 5: Iwc

    Iwc 5 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 4 ratings and technical data notes: 1 = water temperature 7/12°c, air temperature d.B. 27°c, w.B. 19°c, 47% humidity 3 = water temperature 70 - 60°c; air temperature 20°c 4 = sound power conforming to iso 3741...

  • Page 6: Iwc

    Iwc 6 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 5 performances in order to define the performances of iwc subject to conditions different from rated conditions, a computer program for the correct choice of the units is provided by galletti spa. With a few i...

  • Page 7: Iwc

    Iwc 7 lw iwc vr 125 hz 250 hz 500 hz 1000 hz 2000 hz 4000 hz 8000 hz lwa lpa db db db db db db db db/a db/a iwc o32 1 36,1 33,9 25,3 19,7 21,4 16,8 20,0 30,0 25,0 2 42,5 43,4 41,5 32,2 27,0 18,5 19,8 41,0 36,0 3 46,1 46,7 44,0 36,3 29,9 19,9 20,4 44,0 39,0 4 46,7 47,7 45,9 39,8 33,2 22,6 17,7 46,0 4...

  • Page 8: Iwc

    Iwc 8 730 730 544 506 41 min. 544 10 10 10 506 259 41 min. 10 135 600 575 506 e 259 228 192 152 575 600 544 70 296 273 23 41 a c b d 730 730 544 506 41 min. 544 10 10 10 506 259 41 min. 10 135 600 575 506 h 259 228 192 152 575 600 544 70 296 273 23 41 a f e c b d g all copying, even partial, of this...

  • Page 9: Iwc

    Iwc 9 860 760 l 500 h 30 240 48 125 200 z y e d c b a f 30 mini cwx 6 x all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 iwc 06-08, 2 pipes 8 overall dimensions a condensate hole: 32 mm Ø od b water inlet: ¾” gas female c water outlet: ¾” gas female d coil air ven...

  • Page 10: Iwc

    Iwc 10 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections generalities • class 1 unit. • the electrical installation must comply with current standards and regulations (paying particular attention to standards nf c 15-100, cei 364). Details ...

  • Page 11: Iwc

    Iwc 11 pe n u pe n u n f 230v/1/50hz all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections wiring diagrams: models with cable control for the connection to the power supply, use the terminal x1 (terminals u, n and pe) of the printed circuit boa...

  • Page 12: Iwc

    Iwc 12 iwc 3-4 iwc 5 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 13: Iwc

    Iwc 13 iwc 6-8 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 14: Iwc

    Iwc 14 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections 1 - jumper setting c = closed o = open 2 - functions: a = available e = not available (when selected from the remote control, all signals are flashing) note: configurations other than...

  • Page 15: Iwc

    Iwc 15 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections iwc 3-4 with cable control iwc 3-4 with cable control (2 pipes).

  • Page 16: Iwc

    Iwc 16 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections iwc 5 with cable control iwc 6-8 with cable control.

  • Page 17: Iwc

    Iwc 17 iwc + mycomfort base + kp all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 18: Iwc

    Iwc 18 iwc + mycomfort medium + kp all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 19: Iwc

    Iwc 19 iwc + mycomfort large + kp all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 20: Iwc

    Iwc 20 iwc + led503 + kp all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 9 electrical connections.

  • Page 21: Iwc

    Iwc 21 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 10 accessories mycomfort base - wall-mounted microprocessor control, galletti model mycomfort base having the following main features: - room air temperature reading and adjustment - water temperature reading...

  • Page 22: Iwc

    Iwc 22 in out 1 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 10 accessories 3-way motor driven valve and 4x2 motor driven valve kit the kit includes: - brass 3-way valve / 4 connections with built-in by-pass, maximum operating pressure 16 bar; electrothermal o...

  • Page 23: Iwc

    Iwc 23 in out 2 in out 3 in out 4 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 warning: in order to avoid leakage problems, the maximum pressure difference between the hot side and the cold side of the water circuit should be lower than 1 bar. Warning: in orde...

  • Page 24: Iwc

    Iwc 24 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 main heat exchanger water outlet iwc 03-04 4 tubi, iwc 03-04 4 pipes valvola a 2 vie - 2-way valve main heat exchanger water inlet additional heat exchanger water outlet additional heat exchanger water inlet ...

  • Page 25: Iwc

    Iwc 25 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 iwc 06-08 2 tubi, iwc 06-08 2 pipes valvola a 2 vie - 2-way valve water outlet water inlet.

  • Page 26: Iwc

    Iwc 26 all copying, even partial, of this manual is strictly forbidden. Wc66000113 - rev 04 models equipped with infrared remote control, can only mount a motor-driven valve kit with 230 volt actuator * the modulating valves can be managed in models configured for a wired controller. A mycomfort lar...

  • Page 27

    Notes.

  • Page 28

    Www.Galletti.It 40010 bentivoglio (bo) via romagnoli 12/a tel. 051/8908111 - fax. 051/8908122 company uni en iso 9001 and ohsas 18001 certified.