Gamatronic power+ sa User Manual

Other manuals for power+ sa: User manual
Manual is about: 20 KVA, 30 KVA, AND 40 KVA MODELS

Summary of power+ sa

  • Page 1

    G amatronic e lectronic i ndustries l td . 17 hartum st., po box 45029, jerusalem 9777517, israel tel: +972-2-588-8222 fax: +972-2-582-8875 email: info@gamatronic.Co.Il website: www.Gamatronic.Com 2mum-ppsa/7 power + sa ups system 20 k va, 30 k va, and 40 k va models u u s s e e r r g g u u i i d d ...

  • Page 2

    G amatronic e lectronic i ndustries l td . Ii power+ sa : 20, 30 and 40 kva, release 2.1 g amatronic e lectronic i ndustries l td . Har hotzvim industrial park 17 hartum st., p.O.B. 45029, jerusalem 9777517, israel tel: 972-2-588-8222 fax: 972-2-582-8875 email: info@gamatronic.Co.Il website: www.Gam...

  • Page 3: Table Of Contents

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 iii table of contents s afety p recautions .......................................................................................................................... Xiii do’s xiii don’ts .............................

  • Page 4

    G amatronic e lectronic i ndustries l td . Iv power+ sa : 20, 30 and 40 kva, release 2.1 6.8.2 cold start ............................................................................................................ 43 6.8.3 test under load ...............................................................

  • Page 5

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 v 9.12.3.8 enabling/disabling remote commands ....................................................... 114 9.12.4 enabling/disabling current sharing ................................................................ 1...

  • Page 6

    G amatronic e lectronic i ndustries l td . Vi power+ sa : 20, 30 and 40 kva, release 2.1 table of figures figure 1: 20, 30, or 40 kva configuration in a compact cabinet ................................................ 2 figure 2: control panel ...........................................................

  • Page 7

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 vii figure 51: internet protocol (tcp/ip) properties screen ......................................................... 45 figure 52: main screen of built-in web server...................................................

  • Page 8

    G amatronic e lectronic i ndustries l td . Viii power+ sa : 20, 30 and 40 kva, release 2.1 figure 104: battery current ...................................................................................................... 71 figure 105: battery capacity..................................................

  • Page 9

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 ix figure 157: setup menu .......................................................................................................... 89 figure 158: battery setup menu ..................................................

  • Page 10

    G amatronic e lectronic i ndustries l td . X power+ sa : 20, 30 and 40 kva, release 2.1 figure 210: service menu ...................................................................................................... 107 figure 211: set upss ..............................................................

  • Page 11

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 xi figure 263: confirmation screen ............................................................................................ 120 figure 264: silicon menu ............................................................

  • Page 12

    G amatronic e lectronic i ndustries l td . Xii power+ sa : 20, 30 and 40 kva, release 2.1 list of tables table 1: status indicators .......................................................................................................... 9 table 2: operation buttons ...................................

  • Page 13: Afety

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 xiii s afety p recautions the ups system is designed for industrial applications and harsh environments. Nevertheless the ups is a sophisticated power system and should be handled with appropriate care, according t...

  • Page 14: Don’Ts

    G amatronic e lectronic i ndustries l td . Xiv power+ sa : 20, 30 and 40 kva, release 2.1 don’ts • do not open the cover of the ups or the battery cabinets under any circumstances. All ups panels and doors should be closed. • do not insert any objects through the ventilation holes. • do not put obje...

  • Page 15

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 xv.

  • Page 16

    G amatronic e lectronic i ndustries l td . Xvi power+ sa : 20, 30 and 40 kva, release 2.1 this page left blank deliberately..

  • Page 17: Ntroduction

    G amatronic e lectronic i ndustries l td . Power+ sa – 20, 30 and 40 kva, release 2.1 1 1. I ntroduction thank you for purchasing a p ower + sa ups system . The p ower + sa is one of the most sophisticated upss on the market today. In general, an uninterruptible power supply (ups) provides backup po...

  • Page 18

    G amatronic e lectronic i ndustries l td . 2 power+ sa: 20, 30, and 40 kva, release 2.1 figure 1: 20, 30, or 40 kva configuration in a compact cabinet the p ower + sa is comprised of the following sub-assemblies: • system controller • multiple inverter boards (2, 3 or 4, depending on ups output capa...

  • Page 19: 1.2

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 3 1.2 system controller the power+ sa system controller has multiple purposes: • to allow the user to manage and control the ups. • to monitor the parameters of all sections of the power+ sa via the control panel. ...

  • Page 20: Perating Modes

    G amatronic e lectronic i ndustries l td . 4 power+ sa: 20, 30, and 40 kva, release 2.1 2. O perating modes the p ower + sa ups functions to supply ac electrical power to your load. While using the p ower + sa, three modes of operation are possible: • normal operation • battery operation • bypass op...

  • Page 21: 2.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 5 2.3 bypass operation during bypass operation, the load receives power directly from the ac input via the static switch. Whenever the inverters cannot provide power to the load, either due to an overload or a shor...

  • Page 22: Ser Interface

    G amatronic e lectronic i ndustries l td . 6 power+ sa: 20, 30, and 40 kva, release 2.1 3. U ser interface this section describes the buttons and indicators used to operate the power+ . 3.1 control panel the power+ control panel, located on the front of the controller, provides the user with an inte...

  • Page 23: 3.2

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 7 3.2 power+ sa control screen the power+ control screen is illustrated below. It is part of the control panel described on page 6. How to read and understand the power+ control screen is described in detail in cha...

  • Page 24: 3.3

    G amatronic e lectronic i ndustries l td . 8 power+ sa: 20, 30, and 40 kva, release 2.1 3.3 navigation and operation keypad the navigation and operation keypad works in conjunction with the control screen. It allows you to navigate through the available menus using the direction arrow buttons and th...

  • Page 25: 3.4

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 9 3.4 status indicators the status indicators show precisely what is running and how the ups is providing power to the load. The diagram below shows the power source and destination routes in use for each of the 3 ...

  • Page 26: 3.5

    G amatronic e lectronic i ndustries l td . 10 power+ sa: 20, 30, and 40 kva, release 2.1 3.5 operation buttons the operation buttons illustrated below are “soft” switches. • on/off resets the entire ups. • alarm silence shuts the alarm sounder. • inv/byp allows the maintenance engineer to manually c...

  • Page 27: 3.7

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 11 3.7 power+ sa operation modes 3.7.1 normal operation during normal operation, the ups draws power from the ac line, feeds dc to the inverter, which provides ac to the load. Load level ---11:20:25--- l1: _____ 01...

  • Page 28: 3.7.3

    G amatronic e lectronic i ndustries l td . 12 power+ sa: 20, 30, and 40 kva, release 2.1 figure 10: ac power failure indication 3.7.3 bypass operation (automatic) during bypass operation, the ac feeds the load via the bypass static switch. The red alarm flashes to indicate an abnormal status. Load l...

  • Page 29: Nstallation

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 13 4. I nstallation 4.1 installation checklist complete the following checklist as you perform the installation, initialization, configuration, and testing procedures. Refer to the appropriate sections (specified i...

  • Page 30

    G amatronic e lectronic i ndustries l td . 14 power+ sa: 20, 30, and 40 kva, release 2.1 √ operation requirement reference verify dc voltage at battery cabinet switch +384 v and – 384 v 4.3.3 step 5 verify that appropriate ac fuses are present twelve x 15 a fuses 4.3.3 step 6 verify that appropriate...

  • Page 31: 4.2

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 15 4.2 connection diagram figure 13: connection diagram (for completion by the customer).

  • Page 32: 4.3

    G amatronic e lectronic i ndustries l td . 16 power+ sa: 20, 30, and 40 kva, release 2.1 4.3 installation procedure after completing each step in the following installation, go back to the installation checklist and check the corresponding item. The p ower + sa is currently available in two differen...

  • Page 33: 4.3.4

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 17 3. Measure the ac input voltage. Phase-to-phase voltage (measured between l1-l2, l2-l3, and l3-l1) should be 3x400 vac ±10 %. Phase-to-neutral voltage (measured at l1, l2, and l3) should be 230 vac, ±10 %. 4. Ve...

  • Page 34

    G amatronic e lectronic i ndustries l td . 18 power+ sa: 20, 30, and 40 kva, release 2.1 figure 14: wrong way to connect p ower + sa with a four-pole switch.

  • Page 35

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 19 figure 15: acceptable connection for grounded generator and 4-pole switch.

  • Page 36

    G amatronic e lectronic i ndustries l td . 20 power+ sa: 20, 30, and 40 kva, release 2.1 figure 16: preferred generator (neutralized) and connection (3-pole) 4.3.4.2 system connections two wiring diagrams follow, for two different p ower + sa configurations: • 3-phase (figure 17 ). • 3-phase with in...

  • Page 37

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 21 figure 17: system connections for 3-phase configuration.

  • Page 38

    G amatronic e lectronic i ndustries l td . 22 power+ sa: 20, 30, and 40 kva, release 2.1 figure 18: system connections for 3-phase config. With input isol. Transfrmr.

  • Page 39

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 23 table 5: maximum input current for rectifier and bypass to enable the installation technician to choose the appropriate input and output cables, table 5 lists the maximum input current for the 20, 30, and 40 kva...

  • Page 40

    G amatronic e lectronic i ndustries l td . 24 power+ sa: 20, 30, and 40 kva, release 2.1 table 6: recommended input and output cbs / switches table 6 provides recommend ratings for the circuit breakers and/or switches on the ups’s input and output lines. The switches and circuit breakers in table 6 ...

  • Page 41

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 25 4.3.4.3 circuit breaker recommendations table 6 provides recommend ratings for the circuit breakers and/or switches on the ups’s input and output lines. Before connecting any external cables to the ups, read cha...

  • Page 42

    G amatronic e lectronic i ndustries l td . 26 power+ sa: 20, 30, and 40 kva, release 2.1 4.3.4.5 connecting the batteries within the battery cabinet 1. Assemble the batteries within the battery cabinet and make necessary connections to the switch inside the battery cabinet. 2. Measure the dc voltage...

  • Page 43: Ircuit Breaker Selectivity

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 27 5. C ircuit breaker selectivity when discussing power distribution, "discrimination" (also referred to as selectivity) is the selection and arrangement of circuit breakers such that in the event of a short circu...

  • Page 44

    G amatronic e lectronic i ndustries l td . 28 power+ sa: 20, 30, and 40 kva, release 2.1 magnetic (instantaneous) tripping. In most cases we would want the intermediate circuit breaker (cb03) to respond thermally to a short in load 2, but with a shorter delay than that of cb01. In order to protect t...

  • Page 45: Ry Contacts And Alarms

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 29 6. D ry contacts and alarms the p ower + sa optionally includes: • input dry contacts (used to invoke some alarm or action by the p ower + sa). • output dry contacts (send an external signal when specific alarm ...

  • Page 46

    G amatronic e lectronic i ndustries l td . 30 power+ sa: 20, 30, and 40 kva, release 2.1 figure 22: close-up of the special connections as you can see in figure 22 and figure 23, the special connections include two rows of dry contacts. Figure 23: there are two rows of dry contact (and other) connec...

  • Page 47: 6.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 31 figure 24: top row of dry contact pins table 8: dry contact descriptions “inputs” dry contact description name in alarm display com shared contact --- bat cb auxiliary contact (n.C.) for battery circuit breaker ...

  • Page 48: 6.2

    G amatronic e lectronic i ndustries l td . 32 power+ sa: 20, 30, and 40 kva, release 2.1 6.2 temperature sensor (optional) an optional temperature sensor (see figure 25) may be attached to the contacts labeled temp to monitor the temperature of the batteries. Figure 25: bottom row of dry contacts to...

  • Page 49: 6.4

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 33 6.4 the d9 alarm output the d9 alarm output connection is standard equipment on the p ower + sa. Pin usage on the d9 alarm output is described in table 9. The alarm outputs are dry contact relays, normally opene...

  • Page 50: 6.5

    G amatronic e lectronic i ndustries l td . 34 power+ sa: 20, 30, and 40 kva, release 2.1 6.5 special terminal connections this section describes the special-purpose connections of the power+ sa. Figure 27 shows connections to the special terminals located on the rear of the power+ sa, to the right o...

  • Page 51: 6.5.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 35 6.5.3 emergency power-off an external emergency power-off (epo) switch can be installed by the customer to enable immediate shutdown of the ups. Once switched off by the epo, the power+ must be restarted manuall...

  • Page 52: 6.6

    G amatronic e lectronic i ndustries l td . 36 power+ sa: 20, 30, and 40 kva, release 2.1 6.6 power-up (initial startup) initial startup refers to applying power to the ups for the first time or after connection to both mains and battery has been interrupted. Note: initial startup can be performed wi...

  • Page 53

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 37 in “silicon mode” commands issued through the power+ sa control panel are executed immediately. Operators should exercise caution. Wait for results… static ram: passed r.T clock: passed eeprom – 1: passed eeprom...

  • Page 54: 6.7

    G amatronic e lectronic i ndustries l td . 38 power+ sa: 20, 30, and 40 kva, release 2.1 6.7 configuration perform the following configuration steps from the control panel. 6.7.1 check configured modules verify that the number of configured modules matches the desired output power, and verify that t...

  • Page 55

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 39 5. Select configure , option 5, to configure the power+ sa modules: [main menu > setup > (password) > ent > service] 1> ------ 4> dryout test 7> -------- 2> upss 5> configure 8> powr.Calib 3> ------- 6> en/dis s...

  • Page 56: 6.7.2

    G amatronic e lectronic i ndustries l td . 40 power+ sa: 20, 30, and 40 kva, release 2.1 6.7.2 check total ampere-hours this procedure is designed to ensure that the total capacity of the batteries attached to power+ sa matches the definition of the total capacity in the system controller. 1. Check ...

  • Page 57: 6.7.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 41 6.7.3 set date and time and serial number to verify the date and time set in the system controller and make sure that they are correct: 1. Use the and keys to select the year, month, day, hour, minute, or second...

  • Page 58

    G amatronic e lectronic i ndustries l td . 42 power+ sa: 20, 30, and 40 kva, release 2.1 3. Use the arrow keys to set the ip address, and then press ent : [main menu > setup > (password) > ent > service > sc2012 > network > set ip address] set ip address 157.211.000.252 figure 46: ip address 4. Use ...

  • Page 59: 6.8

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 43 6.8 testing perform the following tests on the power+ sa unit. 6.8.1 blackout test this test is designed to verify the operation of power+ sa in the event of a blackout, when no ac power is supplied to the ups. ...

  • Page 60: 6.8.4

    G amatronic e lectronic i ndustries l td . 44 power+ sa: 20, 30, and 40 kva, release 2.1 6.8.4 check ip communication with controller (optional) this test is designed to verify that the system controller is properly configured for communication and that the web server built-in into the system contro...

  • Page 61

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 45 figure 50: local area connection properties screen c. When the local area connection properties screen appears, in the this connection uses the following items window scroll down to internet protocol (tcp/ip) an...

  • Page 62: 6.8.5

    G amatronic e lectronic i ndustries l td . 46 power+ sa: 20, 30, and 40 kva, release 2.1 d. When the internet protocol (tcp/itp properties screen appears, click the use the following ip address button and enter ip address and subnet mask in the appropriate fields. Leave default gateway blank. Make s...

  • Page 63

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 47 1. Click the send sms button on the left sidebar of the main screen of the built-in web server. Figure 53: login screen of built-in web server 2. When the login screen appears, enter admin for both user name and...

  • Page 64: Ower

    G amatronic e lectronic i ndustries l td . 48 power+ sa: 20, 30, and 40 kva, release 2.1 7. P ower + sa r outine s tart - up 7.1 start-up after shutdown this section describes the start-up procedures for the operator after a power+ shutdown. After shutdown, the ups on, alarm and load indicators will...

  • Page 65

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 49 figure 58: normal operation indication 2. Connect the load and observe the results on the display. Load level ---11:20:25--- l1: _____ 015a, 230v battery: 864v l2: ______ 012a, 230v ups ok (on) l3: _______ 011a,...

  • Page 66: 7.2

    G amatronic e lectronic i ndustries l td . 50 power+ sa: 20, 30, and 40 kva, release 2.1 7.2 power+ sa shutdown (switching to bypass) 1. Press twice on the on/off button. 2. Wait 2 minutes for the power+ to shut down. The control screen will indicate ups ok (off). Load level ---22:21:18--- l1:______...

  • Page 67: 7.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 51 7.3 power+ sa total shutdown (no ac output) 1. Switch the load off. 2. Press and hold the on/off button for 10 seconds. 3. The control screen will indicate ups ok (off). Load level ---23:14:40--- l1:__________ 0...

  • Page 68: Ower

    G amatronic e lectronic i ndustries l td . 52 power+ sa: 20, 30, and 40 kva, release 2.1 8. P ower + sa control panel the p ower + sa system is equipped with an lcm display (lcd) and touch pad control panel that enables the user to effectively manage the ups system. Once p ower + sa is installed, th...

  • Page 69: 8.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 53 8.1 quick-reference summary of power+ sa menu functions the following flowcharts detail the structure of the powerplus menus. The symbol directs you to a following chart. For example, means "go to the diagram la...

  • Page 70

    G amatronic e lectronic i ndustries l td . 54 power+ sa: 20, 30, and 40 kva, release 2.1 figure 67: battery menu figure 68: setup menu • inverter voltage. • bypass voltage. • output current. • static switch status bytes. (main menu) static sw. 8 displays: m.8 main menu option 8. Figure 69: static sw...

  • Page 71: M.7.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 55 1. Ac high & low alarm thresholds, ac alarm hysteresis. 2. Batt. End, batt. Low, batt. Hi voltages. 7. Over temp., under temp. 9. Integration factor. Options 1 on the setup menu. (setup menu) alarm set set: m.7....

  • Page 72

    G amatronic e lectronic i ndustries l td . 56 power+ sa: 20, 30, and 40 kva, release 2.1 figure 73: service sub-menu.

  • Page 73

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 57 figure 74: configure sub-sub-menu figure 75: silicon sub-menu.

  • Page 74: Ower

    G amatronic e lectronic i ndustries l td . 58 power+ sa: 20, 30, and 40 kva, release 2.1 9. P ower + sa menu functions in detail this chapter describes the functions available through the power+ main menu and its submenus. Note: if you are viewing this file in pdf format, it is possible to search fo...

  • Page 75: 9.2

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 59 9.2 “system” option figure 77: main menu option 1 ("system") 1. The system option (option 1) shows the dc voltages and current (positive, negative and summary): [main menu > system] batt curr: -----> total +053....

  • Page 76

    G amatronic e lectronic i ndustries l td . 60 power+ sa: 20, 30, and 40 kva, release 2.1 2. View the current output power factors 1 : [main menu > system > ►] output l1 l2 l3 total kva 000.4 000.2 000.2 000.8 kw 000.0 000.0 000.0 000.0 p.F. 0.00 0.00 0.00 0.00 figure 79: output power factor 1 3. Vie...

  • Page 77

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 61 6. View the system jumper settings without remote panel: [main menu > system > ▼ ▼ ▼] jmp: jmp1, jmp2, jmp3, jmp6 and jmp9 =in 1. Not hard silicon 2. Silicon mode 6. No rmt pan. 12369 3. Capacity low 9. Ac: 230v...

  • Page 78

    G amatronic e lectronic i ndustries l td . 62 power+ sa: 20, 30, and 40 kva, release 2.1 10. View status of the fuses: [main menu > system > ▼ ▼ ▼ ▼ ▼ ▼] batt fuse: bad emergency: open user-1: open user-4: open user-2: open 7: open user-3: open 8: open figure 87: fuse status 11. View communication w...

  • Page 79: 9.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 63 9.3 “ups module” option to view voltage and current measurements and other information for each ups module: 1. Use the ▼ and ▲ keys to scroll between ups modules. The display shows the voltage and current measur...

  • Page 80

    G amatronic e lectronic i ndustries l td . 64 power+ sa: 20, 30, and 40 kva, release 2.1 2. View the input and output voltage and current for each phase of a particular ups module. Scroll down ▼ to view other ups modules. [main menu > ups module > ▼] phase: -l1-- -l2-- -l3— in: 000v/000.0a 000v/000....

  • Page 81: 9.4

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 65 9.4 “self-test” option you can run a self-test at any time without interfering in the normal operation of the power+ . A self-test is also initiated by the power+ itself each day at midnight. Figure 94: main men...

  • Page 82: 9.5

    G amatronic e lectronic i ndustries l td . 66 power+ sa: 20, 30, and 40 kva, release 2.1 9.5 “history” (logs) option the last 255 events reserved in the log are displayed, as shown in figure 97. Figure 96: main menu option 4 (“history”) 1. Navigate the log by scrolling using the ▲ and ▼ keys. [main ...

  • Page 83

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 67 2. View more details by pressing the ► key. [main menu > history > ►] time date 1 2 3 4 5 6 7 8 # 14:36:16 28.02.10 254 14:37:01 28.02.10 255 12:27:26 27.02.10 000 figure 98: history log scroll table 11 lists th...

  • Page 84

    G amatronic e lectronic i ndustries l td . 68 power+ sa: 20, 30, and 40 kva, release 2.1 table 11: log messages # m essage e xplanation 01 upsmaj more than 1 ups module is sending an alarm or fault warning 02 upsmin single ups module is sending an alarm or fault warning 03 ------ n.A. 04 ------ n.A....

  • Page 85

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 69 data – dc voltage between + and – terminals for all events except loadbp and stsw status for loadbp events. (see below.) even start (in) and end (out) description – (see table 11 above) event number – 0 through ...

  • Page 86: 9.6

    G amatronic e lectronic i ndustries l td . 70 power+ sa: 20, 30, and 40 kva, release 2.1 9.6 “battery” option the battery option on the main menu displays information about battery capacity, battery voltage and current, and battery test. Figure 99: main menu option 5 (“battery”) 1. View the battery ...

  • Page 87

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 71 2. View next automatic equalizing, remaining equalizing time, total rectifier current, and battery (charging) current: [main menu > battery > ▼] next automatic equalizing: 02 days remaining equalizing time: ___ ...

  • Page 88

    G amatronic e lectronic i ndustries l td . 72 power+ sa: 20, 30, and 40 kva, release 2.1 6. View battery capacity: [main menu > battery > ▼> ▼> ▼> ▼> ▼] 1> battery#1: 020 ah total cap.: 0020 ah figure 105: battery capacity note:figure 103, figure 104, and figure 105 show the individual batteries on ...

  • Page 89: 9.7

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 73 9.7 “alarm” option alarms are displayed—there are 32 in all. In addition, there are some screens for use by a technician. Figure 107: main menu option 6 (“alarm”) 1. View alarms 01-12: a + or – before an alarm n...

  • Page 90

    G amatronic e lectronic i ndustries l td . 74 power+ sa: 20, 30, and 40 kva, release 2.1 2. View alarms 13-24: [main menu > alarm > ▼] 13 – 15 +stswrn: +e.P.O.:* -eq-hst: 16 – 18 +batflt:* +user-1: -user-2: 19 – 21 +user-3: +ac-brn: +acin-h: 22 – 24 +acfail: +stswcm:* +slfflt:* figure 109: alarms 13...

  • Page 91: 9.8

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 75 9.8 “setup – alarm set” option main menu options system ups module selftest history battery alarm setup static sw. 1) ac volt 2) float volt 7) temperature 9) integrat. 1) set ac high & low alarm levels 2) set ac...

  • Page 92: 9.8.1

    G amatronic e lectronic i ndustries l td . 76 power+ sa: 20, 30, and 40 kva, release 2.1 2. Select alarm set: [main menu > setup > (password) > ent] 1> alarm set 5> time 9> silicon 2> module conf. 6> site 3> battery 7> password #1 4> charge 8> service 1 figure 113: setup menu 9.8.1 setting ac voltag...

  • Page 93: 9.8.2

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 77 4. Select set ac alarms hysteresis : [main menu > setup > ent > (password) > ent > alarm set > ac volt] 1> set ac high & low alarm levels 2> set ac alarms hysteresis please select 1 figure 117: ac alarms menu 5....

  • Page 94

    G amatronic e lectronic i ndustries l td . 78 power+ sa: 20, 30, and 40 kva, release 2.1 3. Use the arrow keys to set batend and press ent : [main menu > setup > (password) > alarm set > float volt > batend] floating charge alarm setup voltage setting: 340.0v figure 121: set batend 4. Select batlow ...

  • Page 95: 9.8.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 79 7. Use the arrow keys to set bat-hi , press ent , and then esc : [main menu > setup > (password) > alarm set > float volt > bat-hi] floating charge alarm setup voltage setting: 475.0v figure 125: set bat-hi 9.8....

  • Page 96: 9.8.4

    G amatronic e lectronic i ndustries l td . 80 power+ sa: 20, 30, and 40 kva, release 2.1 4. Select under temperature : [main menu > setup > (password) > alarm set > temperature] 1> over temperature 2> under temperature please select figure 129: over/under temperature menu 5. Use the arrow keys to se...

  • Page 97

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 81 2. Use the arrow keys to set the integration factor alarm value—press ent to accept or esc to discard: [main menu > setup > (password) > alarm set > integrat.] set integration factor (1 – 30) enter = accept 05 e...

  • Page 98: 9.9

    G amatronic e lectronic i ndustries l td . 82 power+ sa: 20, 30, and 40 kva, release 2.1 9.9 “setup – module conf.” option main menu options - - - module config. Submenu options - - - system ups module selftest history battery alarm setup static sw. 2) module config. Password: 1) num of phase 2) mod...

  • Page 99: 9.9.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 83 2. Select module conf. : [main menu > setup > (password) > ent] 1> alarm set 5> time 9> silicon 2> module conf. 6> site 3> battery 7> password #1 4> charge 8> service figure 135: setup menu 9.9.1 setting number ...

  • Page 100: 9.9.3

    G amatronic e lectronic i ndustries l td . 84 power+ sa: 20, 30, and 40 kva, release 2.1 9.9.3 setting module/s voltage 1. Select module/s voltage : [main menu > setup > (password) > module conf.] 1. Num of phase 5.Output adjust 2. Module/s frequency 6.Frequency limits 3. Module/s voltage 7.Dc calib...

  • Page 101: 9.9.5

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 85 9.9.5 output adjustment 1. Select output adjust : [main menu > setup > (password) > module conf.] 1. Num of phase 5.Output adjust 2. Module/s frequency 6.Frequency limits 3. Module/s voltage 7.Dc calibration 4. ...

  • Page 102: 9.9.6

    G amatronic e lectronic i ndustries l td . 86 power+ sa: 20, 30, and 40 kva, release 2.1 9.9.6 setting frequency limits 1. Select frequency limits : [main menu > setup > (password) > module conf.] 1. Num of phase 5.Output adjust 2. Module/s frequency 6.Frequency limits 3. Module/s voltage 7.Dc calib...

  • Page 103: 9.9.8

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 87 3. Adjust the measured value using the arrow keys, and press ent to update: [main menu > setup > (password) > module conf. > dc calibration > ent] module v. Calib – 15 sec to expire ####### press enter to update...

  • Page 104

    G amatronic e lectronic i ndustries l td . 88 power+ sa: 20, 30, and 40 kva, release 2.1 9.10 “setup – battery” option - - - battery submenu options - - - 1) test-voltage 2) test alarm 3) current-limit.. 4) temp compensat. 5) battery test... 6) capacity 0020 ah) 7) ‘auto’ test 8) enable/dis options ...

  • Page 105: 9.10.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 89 1. To enter setup, use the default password (left arrow key eight times). [main menu > setup] power+ system setup type in level-1 password, then – enter your privilege will expire after 15 min. Password:________...

  • Page 106: 9.10.2

    G amatronic e lectronic i ndustries l td . 90 power+ sa: 20, 30, and 40 kva, release 2.1 9.10.2 setting battery test voltage alarm 1. Select test alarm : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’ test 4...

  • Page 107: 9.10.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 91 9.10.3 setting battery current limit 1. Select current-limit.. : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’ test 4...

  • Page 108: 9.10.4

    G amatronic e lectronic i ndustries l td . 92 power+ sa: 20, 30, and 40 kva, release 2.1 9.10.4 enable/disable battery current limit 1. Select current-limit.. : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’...

  • Page 109: 9.10.5

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 93 9.10.5 setting temperature compensation 1. Select temp compensat. : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’ tes...

  • Page 110: 9.10.6

    G amatronic e lectronic i ndustries l td . 94 power+ sa: 20, 30, and 40 kva, release 2.1 9.10.6 setting disable temperature compensation 1. Select temp compensat. : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘a...

  • Page 111

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 95 2. Select set absolute minimum output voltage : [main menu > setup > (password) > battery > temp. Compensat. > set absolute max & min voltages] 1> set absolute minimum output voltage 2> set absolute maximum outp...

  • Page 112: 9.10.8

    G amatronic e lectronic i ndustries l td . 96 power+ sa: 20, 30, and 40 kva, release 2.1 9.10.8 activating the battery test 1. Select battery test… : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’ test 4> te...

  • Page 113

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 97 2. Select set auto battery test period and then press ent : [main menu > setup > (password) > battery > battery test…] 1> activate battery test… 2> set auto battery test period 3> set auto battery test top time ...

  • Page 114: 9.10.11  Setting The N

    G amatronic e lectronic i ndustries l td . 98 power+ sa: 20, 30, and 40 kva, release 2.1 3. Using the arrow keys, set the battery test top time, and then press ent : [main menu > setup > (password) > battery > battery test…> set auto battery test top time] set top time for battery test (1 – 9) hours...

  • Page 115

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 99 9.10.12 activating ‘auto’ test 1. Select ‘auto’ test : [main menu > setup > (password) > battery] 1> test-voltage 5> battery test… 2> test alarm 6> capacity 0020 ah) 3> current-limit.. 7> ‘auto’ test 4> temp com...

  • Page 116

    G amatronic e lectronic i ndustries l td . 100 power+ sa: 20, 30, and 40 kva, release 2.1 2. Select enable shutdown by long ac fail (off) and press ent to toggle enable/disable: [main menu > setup > (password) > battery > enable/dis options] 1> enable shutdown by long ac fail (off) 2> enable current...

  • Page 117: Options

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 101 9.11 setup – charge, time, site, and password options system main menu options ups module self test history battery alarm setup static sw. 4) charge password: charge, time, site, and password - - - submenu opti...

  • Page 118: 9.11.1

    G amatronic e lectronic i ndustries l td . 102 power+ sa: 20, 30, and 40 kva, release 2.1 9.11.1 setting the floating charge 1. Select charge: [main menu > setup > (password) > ent] 1> alarm set 5> time 9> silicon 2> module conf. 6> site 3> battery 7> password #1 4> charge 8> service figure 197: set...

  • Page 119: 9.11.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 103 2. Using the arrow keys, set the date and time, and then press ent : [main menu > setup > (password) > time] set real time year month day hour min sec 2011 09 30 23 58 00 figure 201: set date and time 9.11.3 se...

  • Page 120: 9.11.4

    G amatronic e lectronic i ndustries l td . 104 power+ sa: 20, 30, and 40 kva, release 2.1 9.11.4 changing the password 1. Select password #1 : [main menu > setup > (password) > ent] 1> alarm set 5> time 9> silicon 2> module conf. 6> site 3> battery 7> password #1 4> charge 8> service figure 204: set...

  • Page 121

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 105 9.12 “setup – “service” option main menu options system ups module selftest history battery alarm setup static sw. 2) upss 4) dryout test 6) en/dis shar 9) sc2012…. Ups setup ◄►▲▼ , 1) restart controller - - - ...

  • Page 122

    G amatronic e lectronic i ndustries l td . 106 power+ sa: 20, 30, and 40 kva, release 2.1 1) # of upss (redundancy) 2) # of upss (total) 3) # of batt 4) static switch setup 5) dry, alarms 6) calibration 7) parallel/ standalone 8) rem command set number of redundant ups modules ◄►▲▼ set total number ...

  • Page 123: 9.12.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 107 2. Select service : [main menu > setup > (password) > ent] 1> alarm set 5> time 9> silicon 2> module conf. 6> site 3> battery 7> password #1 4> charge 8> service figure 209: setup menu 9.12.1 setting upss 1. Se...

  • Page 124: 9.12.3

    G amatronic e lectronic i ndustries l td . 108 power+ sa: 20, 30, and 40 kva, release 2.1 2. Press ▲ slowly to test each relay, and press esc when finished: [main menu > setup > (password) > ent > service > dryout test] relay status: press ‘up’ and repeat for relay test(04) 123456 contacts 1-6 =on, ...

  • Page 125

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 109 9.12.3.2 total number of upss 1. Select # of upss (total) : [main menu > setup > (password) > ent > service > configure] 1> # of upss (redundancy) 5> dry, alarms 2> # of upss (total) 6> calibration 3> # of batt...

  • Page 126

    G amatronic e lectronic i ndustries l td . 110 power+ sa: 20, 30, and 40 kva, release 2.1 9.12.3.4 setting up the static switch 1. Select static switch setup : [main menu > setup > (password) > ent > service > configure] 1> # of upss (redundancy) 5> dry, alarms 2> # of upss (total) 6> calibration 3>...

  • Page 127

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 111 9.12.3.5 setting up the dry alarms 1. Select dry, alarms : [main menu > setup > (password) > ent > service > configure] 1> # of upss (redundancy) 5> dry, alarms 2> # of upss (total) 6> calibration 3> # of batt ...

  • Page 128

    G amatronic e lectronic i ndustries l td . 112 power+ sa: 20, 30, and 40 kva, release 2.1 9.12.3.6 calibrating dc currents 1. Select calibration : [main menu > setup > (password) > ent > service > configure] 1> # of upss (redundancy) 5> dry, alarms 2> # of upss (total) 6> calibration 3> # of batt 7>...

  • Page 129

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 113 5. Press ent to continue: [main menu > setup > (password) > ent > service > configure > calibration > dc- i calibration] 1> calibrate battery #1 current figure 233: calibrating dc current 6. Using the arrow key...

  • Page 130: 9.12.4

    G amatronic e lectronic i ndustries l td . 114 power+ sa: 20, 30, and 40 kva, release 2.1 9.12.3.8 enabling/disabling remote commands 1. Select rem command : [main menu > setup > (password) > ent > service > configure] 1> # of upss (redundancy) 5> dry, alarms 2> # of upss (total) 6> calibration 3> #...

  • Page 131: 9.12.5

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 115 9.12.5 setting power factor correction 1. Select powr.Calib : [main menu > setup > (password) > ent > service] 1> ------ 4> dryout test 7> -------- 2> upss 5> configure 8> powr.Calib 3> ------- 6> en/dis shar 9...

  • Page 132

    G amatronic e lectronic i ndustries l td . 116 power+ sa: 20, 30, and 40 kva, release 2.1 3. Select factory settings : [main menu > setup > (password) > ent > service > sc2012] 1> restart controller 3> network… 2> factory settings 4> reset mbx your selection: 1 5> -------------- enter if you are sur...

  • Page 133

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 117 7. Select gateway : [main menu > setup > (password) > ent > service > sc2012 > network] 1> set ip address 157.211.000.253 2> set gateway 157.211.000.251 3> set mask 255.255.255.000 4> store 5> snmp factor selec...

  • Page 134

    G amatronic e lectronic i ndustries l td . 118 power+ sa: 20, 30, and 40 kva, release 2.1 11. Select store : [main menu > setup > (password) > ent > service > sc2012 > network] 1> set ip address 157.211.000.253 2> set gateway 157.211.000.251 3> set mask 255.255.255.000 4> store 5> snmp factor select...

  • Page 135

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 119 9.13 “setup – “silicon” option system main menu options ups module self test history battery alarm setup static sw. Password: 2) reset log 3) defaults 5) reset total time 6)last maint. Set 1) restore factory de...

  • Page 136

    G amatronic e lectronic i ndustries l td . 120 power+ sa: 20, 30, and 40 kva, release 2.1 3. Select reset log and then ent to clear the log: [main menu > setup > (password) > ent > silicon] 1> ----- 5> reset total time 2> reset log 6> last maint. Set 3> defaults... 4> ----- figure 260: silicon menu ...

  • Page 137

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 121 6. Select reset total time or last maint. Set if needed: [main menu > setup > (password) > ent > silicon] 1> ----- 5> reset total time 2> reset log 6> last maint. Set 3> defaults... 4> ----- figure 264: silicon...

  • Page 138

    G amatronic e lectronic i ndustries l td . 122 power+ sa: 20, 30, and 40 kva, release 2.1 9.14 “static switch” option static switch status is displayed: • inverter voltages and frequencies for each phase • bypass voltages and frequencies for each phase • output currents for each phase • ssw relay st...

  • Page 139: 9.15.1

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 123 9.15 system controller setup verification the screens described below are useful for verifying system operation after replacing a controller module(s). Especially important are the screens shown under the gener...

  • Page 140: 9.15.2

    G amatronic e lectronic i ndustries l td . 124 power+ sa: 20, 30, and 40 kva, release 2.1 9.15.2 connection status of upss in the screen shown in figure 270, upss 1 and 2 are connected and upss 3 and 4 are not connected. Upss 5 – 9 are non-existent. [3-second esc > upss stat] stat:123456789 ups : fi...

  • Page 141: 9.15.5

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 125 9.15.5 network parameters the network parameters shown below define a specific power+ sa unit. [3-second esc > network…] ip 157.211.000.253 gateway: 157.211.000.251 mask: 255.255.255.000 faults: 090,073 figure ...

  • Page 142: 9.15.8

    G amatronic e lectronic i ndustries l td . 126 power+ sa: 20, 30, and 40 kva, release 2.1 9.15.8 setting the menu language select the desired menu language using the ▲▼ keys and press ent : [3-second esc > language] ----- language setup ----- select - 1: english (selected) select - 2: spanish select...

  • Page 143

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 127 e. C.Lim.=off (value) : battery current limit function is de-activated (off) or maximum battery current value in amps. If c.Lim is activated, the system must be equipped with an optional battery current sensor....

  • Page 144

    G amatronic e lectronic i ndustries l td . 128 power+ sa: 20, 30, and 40 kva, release 2.1 h. Curr.Sensor : dis or en. Optional battery current sensor is disabled/ enabled. In most applications, it must be disabled. 9.15.9.3 third general screen from the screen shown in the previous section, press ► ...

  • Page 145: 10.

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 129 10. T he built - in w eb interface the power+ sa built-in web interface enables you to monitor and control the power+ sa from a distance, using a pc over an ethernet network. All that is required is an html bro...

  • Page 146: 10.2  Main Screen

    G amatronic e lectronic i ndustries l td . 130 power+ sa: 20, 30, and 40 kva, release 2.1 figure 282: main screen of the power+ sa web interface 10.2 main screen the main screen (see figure 282 above) is the first screen you see when connecting to the gmaci software. The column on the left side of t...

  • Page 147

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 131 10.3 the main menu and its options the main menu of power+ sa’s built-in remote management software consists of a column of option buttons on the left side of the main screen (see figure 282 on page 130). Table...

  • Page 148: 10.3.1

    G amatronic e lectronic i ndustries l td . 132 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.1 “analysis” main menu option the main menu’s “analysis” option lists current values for voltage, current, apparent power (kva), active power (kw), and power factor, for each input and output phase. Figure...

  • Page 149: 10.3.3

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 133 10.3.3 “stsw” (static switch) main menu option the “stsw” (static switch) option on the main menu displays the real-time voltage and frequency measurements for the inverter output voltage and the bypass voltage...

  • Page 150: 10.3.4

    G amatronic e lectronic i ndustries l td . 134 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.4 “log” main menu option figure 286: listing the log entries table 15: data items on the event log screen m enu option d escription id this is simply a line number. In / out “in” indicates the start of an ...

  • Page 151

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 135 table 16: alarm message text in web interface log display (use the alarm number in this table to reference table 11 on page 68 for a fuller explanation of the alarm condition.) l og messages , in alphabetical o...

  • Page 152: 10.3.5

    G amatronic e lectronic i ndustries l td . 136 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.5 “control” main menu option the “control” main menu option enables the user to initiate any of a number of ups processes. The commands available are described in table 17 below. Figure 287: the "control" ...

  • Page 153: 10.3.6

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 137 at the bottom of the “control” screen are two links: simulate ups output source on battery: clicking on this link simulates the conditions in effect during an ac power failure –a signal is sent via snmp to any ...

  • Page 154: 10.3.7

    G amatronic e lectronic i ndustries l td . 138 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.7 “configuration” main menu option choosing the “configuration” option on the web interface’s main menu displays the configuration (sub) menu. Through this menu, various important ups settings can be modif...

  • Page 155

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 139 10.3.7.1 network configuration the “network configuration” option on the configuration menu is equivalent to navigating to setup > service > sc2012 > network on the power+ sa physical control panel. Here you de...

  • Page 156

    G amatronic e lectronic i ndustries l td . 140 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.7.3 set user name and password the “set user name and password” on the configuration submenu enables you to change the user-id and password used for entry into the options on the web interface’s configurat...

  • Page 157

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 141 10.3.7.4 snmp security the snmp security screen is where you define the snmp communities that will have access to the power+ sa, and whether that access will be “read only” (requests for data – a “read- only”) ...

  • Page 158

    G amatronic e lectronic i ndustries l td . 142 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.7.6 shutdown targets the “shutdown targets” option of the configuration menu is where you record the ip address of the computers that you want to perform an orderly shutdown in the event of an ac mains pow...

  • Page 159

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 143 h ow auto - shutdown works : in the event of an ac power mains failure, the power+ sa sends a notification to the ip addresses defined in the pc notification and shutdown screen. This generates a pop-up message...

  • Page 160

    G amatronic e lectronic i ndustries l td . 144 power+ sa: 20, 30, and 40 kva, release 2.1 10.3.7.7 defining email notification targets the web interface enables you to have notifications of system alarm conditions sent by email. To use this feature, the outgoing email server must be defined in the “...

  • Page 161

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 145 10.3.7.8 defining sms notifications the “sms notifications” option of the configuration menu enables you to define telephone numbers that are to receive notification via sms in the event of specific alarm condi...

  • Page 162: 11.

    G amatronic e lectronic i ndustries l td . 146 power+ sa: 20, 30, and 40 kva, release 2.1 11. Snmp agent the power+ sa controller includes an snmp 1 agent that enables remote monitoring and control of the power+ sa, and automatic orderly shutdown of any servers powered by the ups. The snmp agent pro...

  • Page 163: 12.

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 147 12. W ireless control ( optional ) the power+ system includes an option for wireless control and management, using the gamatronic wing. The wing allows real-time detection of power system faults and immediately...

  • Page 164

    G amatronic e lectronic i ndustries l td . 148 power+ sa: 20, 30, and 40 kva, release 2.1 figure 300: connections between the power+ controller and the wing 5. Connect the supplied power cable between the 12 vdc socket on the left side of the controller rear panel and the wing. 6. On a computer that...

  • Page 165

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 149 7. From the wing home page, navigate to configuration > sms notifications . 8. Enter the telephone numbers to which you want to have alarm notifications sent. 9. Commands and queries can be sent to the wing fro...

  • Page 166

    G amatronic e lectronic i ndustries l td . 150 power+ sa: 20, 30, and 40 kva, release 2.1 table 21: list of sms commands.

  • Page 167: 13.

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 151 13. U sing a m aintenance b ypass s witch an external maintenance bypass switch can be connected to the ups. 13.1 putting the ups into maintenance bypass mode when present, an external maintenance bypass switch...

  • Page 168

    G amatronic e lectronic i ndustries l td . 152 power+ sa: 20, 30, and 40 kva, release 2.1.

  • Page 169: 14.

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 153 14. P reventive m aintenance every gamatronic ups contains technologically advanced electronic systems. These electronic systems are sensitive to environmental conditions. It is important that the operating and...

  • Page 170: 16.

    G amatronic e lectronic i ndustries l td . 154 power+ sa: 20, 30, and 40 kva, release 2.1 16. R elated products 16.1 g4 figure 303: gmaci g4 the g4 adds value to your power+: • option to connect external temperatures sensors. • input dry contacts available for on/off external sensors. • output dry c...

  • Page 171: 16.2  G-Eye

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 155 16.2 g-eye figure 304: g-eye g-eye adds value to your power+: • option to connect external temperatures sensors, humidity sensors, and frequency sensors. • inputs for ac/dc current and voltage measurements thro...

  • Page 172: 17.

    G amatronic e lectronic i ndustries l td . 156 power+ sa: 20, 30, and 40 kva, release 2.1 17. P ower + sa specifications table 22: specifications p ower + sa technical data 20 kva 30 kva 40 kva topology on line battery, double conversion, vfi input voltage 3 x 400 vac + n (3 x 230 vac + neutral) vol...

  • Page 173

    G amatronic e lectronic i ndustries l td . Power+ sa : 20, 30 and 40 kva, release 2.1 157 system controller – technical data microcontroller core 16 bit display 4 × 40 characters lcd with backlight other indicators 8 leds, buzzer analog input channels 3 for battery current measurement 1 for temperat...

  • Page 174

    G amatronic e lectronic i ndustries l td . 158 power+ sa: 20, 30, and 40 kva, release 2.1 for a full company profile, please visit our website at www.Gamatronic.Com . Gamatronic building, jerusalem, israel gamatronic’s product range : ups systems power systems for telecom dc-to-ac inverters dc-to-dc...