Ganz C-AllView Installer's Manual - page 13
Connecting external links
1 Openoneormoreoftheknock-outpanelsofthewiringcentreboxandfitsuit-
ablecablewater-sealingcablegrommets,asrequired.
2 Feedthecablesfromtheexternaldevice(s)throughthegrommet(s)andconnect
eachcablewithinthewiringcentreasfollows:
•
Primaryvideo-Theprimaryvideooutputfromthecameraisavailableatthe
BNCsocketlabelled‘VIDEOOUT1’.
Note: If the camera and control system are configured to use coax based telem-
etry, it will pass through this connector.
•
Secondaryvideo-Whenused,theoutputfromthethermalimagingcamerais
availableattheBNCsocketlabelled‘VIDEOOUT2’.
•
RS485telemetry-ConnectRS485A(RS485+)tothelowerterminalmarked
DATA5.ConnectRS485B(RS485-)tothelowerterminalmarkedDATA6.
•
Mainsinput-ConnectthemainsEarth(Yellow/Green)conductortothemiddle
contactoftheconnectorblock.ConnectthemainsLive(Brown)conductorto
thecontactoftheconnectorblockclosesttotheinputfuse.Connectthemains
Neutral(Blue)conductortothecontactoftheconnectorblockfurthestfromthe
inputfuse.
IMPORTANT: The supplier mains input cable to the wiring centre should
have an isolator fitted and be fused according to its gauge and local elec-
trical regulations. Failure to observe such regulations may result in injury
or death.
•
Washer(orsimilardevice)-Whenacameralenswasherpumpisused,make
thefollowingconnectionswithinthepowersupply:
6
5
4
3
AUX POWER
485
-
485
+
AMP
-
AMP
+
R OUTPUT
ER FEED
DATA
2
1
L0
1P
2P
1N
2N
PTZ
WASHER
PUMP
L1
L2
Washer
pump
(VAC)
L
N
TheWASHERPUMP2Pand2N
contactsprovidepermanent
24VACLiveandNeutralpower
output,respectively.
TheAUX1and2contacts
providevoltfreerelayswitching
undersoftwarecontrol(viathe
cameramenuorpresetcodes).
LinktheWASHERPUMP2P
terminaltotheAUX1terminal.
LinkWASHERPUMP2Ntothe
neutralterminalofthepump
andconnecttheliveterminal
ofthepumptoAUX2.