Gardena 10000 SL Inox Operating Instructions Manual - 5. Cleaning
17
GB
17
Flushing the Pump :
Cleaning the suction
base and impeller :
5. Cleaning
The pumps are virtually maintenance-free.
After having pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear
water.
Warning ! Electric shock !
A
Risk of injury due to electric shock.
V Disconnect the pump from the mains before clean-
ing the suction base and impeller.
1. Only for 10000 SL Inox : Unscrew the Phillips screw
A
and pull the suction base cover
0
off the suction base
6
.
2. Unscrew the 6 Phillips screws
8
and pull the suction base
6
off the pump.
3. Clean suction base
6
, impeller
9
and suction base cover
0
if necessary.
4. Reinstall the suction base
6
and screw in the Phillips screws
8
.
5. Only for 10000 SL Inox : Insert the suction base cover
0
into
the suction base
6
and screw in the Phillips screw
A
.
Note for 10000 SL Inox :
It is often sufficient to simply remove the suction base cover
0
and clean the suction base cover
0
and suction base
6
.
For safety reasons a damaged impeller
9
can only be ex-
changed by the GARDENA Service Centre.
6. Trouble-Shooting
Problem
Probable cause
Remedy
Pump is running,
Air cannot escape, since
v Open pressure line
but doesn’t deliver.
pressure line is closed.
(e.g. kinked pressure pipe).
Air locks in the suction base.
v Wait for max. 60 seconds
until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.
Impeller clogged.
v Disconnect plug and clean
impeller (see 5. Cleaning).
When starting the pump,
v Submerge pump deeper.
water height falls below the
min. water level.
Pump doesn’t start or
Thermal overload switch has
v Disconnect plug and clean
suddenly stops during
switched the pump off due
impeller (see 5. Cleaning).
operation.
to overheating.
Observe max. media temper-
ature of 35 °C.
9
6
0 A
8
9
6
8