Gardena 7878 Operating Instructions Manual - 8. Accessories
11
GB
2. FSP 5500 DUO / FSP 8000 DUO / FSP 15000 DUO : Turn
pump housing
0
anti-clockwise and pull vertically off the motor
housing
A
.
FSP 2000 / FSP 3000 : Release the catches
C
and pull the
pump housing
0
off the motor housing
A
.
3. Clean the motor housing
A
and pump housing
0
.
4. FSP 2000 / FSP 3000 : Pull the impeller unit
D
out of the motor
housing
A
clean and push back into the motor housing
A
.
During assembly, ensure that the seal / foam filter
B
is correctly
seated in the motor housing
A
.
5. FSP 5500 DUO / FSP 8000 DUO / FSP 15000 DUO : Press
pump housing
0
vertically onto the motor housing
A
. and turn
clockwise.
FP 2000 / FP 3000 : Press pump housing
0
onto the motor
housing
A
.
Fault
Possible Cause
Remedy
No water being conveyed
Mains plug not plugged in.
V Plug in mains plug.
Impeller unit blocked.
V Clean pump.
Thermal overload switch has
1. Unplug the mains plug and
been activated
allow the pump to cool.
(pump has run dry).
2. Plug the mains plug back in
after approx. 2 minutes.
Reduced amount of water
Filter housing is dirty.
V Clean filter housing.
being conveyed
If any other faults arise, please contact GARDENA Service.
7. Storing your Fountain Pump Set
The pump should be stored out of the reach of children.
1. Remove the pump from the pond before frost is expected and
clean.
2. To avoid difficulties when starting up in the spring, we
recommend storing the pump in a frost-free location in
a container filled with water.
The mains plug must not be submerged.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
8. Accessories
GARDENA pond filter
Cleaning garden ponds with and without fish.
GARDENA
For designing and creating your own water feature.
Pond Construction Products
(e.g. a stream).
GARDENA Hoses
For connection between pump and filter.
Overwintering :
0
D
A
B
C
Disposal :
(in accordance with
RL 2002 / 96 / EC)