Gardena FP 1000 E Operating Instructions Manual - 6. Trouble-Shooting
13
GB
6. Trouble-shooting
Warning ! Electric shock !
V Disconnect the pump from the mains before working
on it.
1. Remove pump from the filter housing (see 5. Maintenance).
2. FP 750 E : Detach the cap
G
from the motor housing
F
at the
catches
H
.
Other pumps : Turn the pump housing
E
anticlockwise and
pull it vertically off the motor housing
F
.
3. Pull impeller unit
I
out of the motor housing
F
and clean.
4. Push cleaned impeller unit
I
back into the motor housing
F
.
5. FP 750 E : Push pump cap
G
onto motor housing
F
.
Other pumps : Press pump housing
E
vertically onto motor
housing
F
and turn clockwise.
FP 4000 E / FP 5000 E / FP 7500 E :
During assembly, ensure that the seal / foam filter
J
is correctly
seated in the motor housing
F
.
Fault Possible
cause
Remedy
No water feature operating
Mains plug not plugged in.
v Plug in mains plug.
Impeller unit is blocked.
v Clean pump.
Regulating valve at pump or
v Open the appropriate
pond edge controller is closed.
regulating valve.
FP 1800 E / FP 2500 E /
Thermal overload switch has
1. Unplug the mains plug
FP 7500 E
been triggered
and allow the pump to cool
(pump has run dry).
2. Plug the mains plug back
in after approx. 2 minutes.
FP 750 E FP 1000 /
Electronic dry-running safety
v Unplug the mains plug,
FP 1400 E / FP 4000 E /
has been triggered.
stand the pump in the
FP 5000 E / FP 7500 E
water and plug the
mains plug back in.
Water feature reduced in
Water feature insert is dirty.
v Clean water feature
size and uneven
insert and nozzle pipe.
Air lock in the hose.
v Fill connection hose for
pond edge filter/pump with
water.
(see 4. Initial Operation).
Filter housing / pond
v Clean filter housing / -
edge filter dirty.
pond edge filter.
If any other faults arise, please contact GARDENA Service.