GARDINER TECHNOLOGY Gardtec 800 Installation Instructions Manual

Other manuals for Gardtec 800: User Instructions

Summary of Gardtec 800

  • Page 1

    G g g g a a a a r r r r d d d d t t t t e e e e c c c c 8 8 8 8 0 0 0 0 0 0 0 0 s s s s e e e e rr rr ii ii e e e e s s s s installation instructions gardiner technology 4344r12.Qxd 03/09/99 11:09 page 1.

  • Page 2: Contents

    Gardtec 800 series contents page 1 contents 1 i ntroduction ............................................................3 2 s ystem o verview .....................................................4 codes .............................................................4 zones ...............................

  • Page 3: Impor

    Page 2 1 i ntroduction the gardtec 800 series of control panels consists of two main parts, the master control panel and the keypad(s). The master control panel is a blank end station if the metal version is used or, the keypad may be mounted on board if the polycarbonate version is used with standa...

  • Page 4

    Gardtec 800 series system overview area codes (controlling specific areas) cleaner (area 0) area 1 area 2 area 3 main area 1 main area 2 main area 3 these area codes will only control their specific areas. Area codes are 'low level codes' and have no user options, they will however allow for the par...

  • Page 5

    Gardtec 800 series system overview zone expansion an expansion path is available through zone expander boards. Each expander board being programmable for 4 x four wire zones, 8 x two wire zones or 8x two wire eol zones. Up to eight expander boards may be fitted to a gardtec 840 giving a total of eig...

  • Page 6

    3 s ystem i nstallation planning the system time should be taken to plan the system. Because the master control panel may be a blank end station it may be looked upon as an engineer box requiring no attention from the end user. When choosing a location for the master control panel consideration shou...

  • Page 7

    Gardtec 800 series system installation page 11 control panel mounting remove the two lid securing screws (single screw on polycarbonate version see fig1) then (pushing in side buttons on polycarbonate version) pull the lid forwards and lift clear of the lid securing lip. Store the lid in a safe plac...

  • Page 8

    System installation page 13 page 12 system installation a second style of keypad known as the gardtec 800 series compact led keypad is also available. To mount this keypad remove the bottom flap securing screw and remove the bottom flap by pulling it forwards and downwards in one movement. The front...

  • Page 9

    Page 15 page 14 system installation 4 w iring c onnections with the exception of the mains wiring all interconnections should be made with multicore 7/.02 alarm cable. Good wiring practice should be observed throughout the installation and the following tips may prove useful. Never run alarm cables ...

  • Page 10

    Wiring connections page 17 page 16 wiring connections keypad terminal connections some keypads that are compatible with other gardiner technology control panels may have additional markings as well as the gardtec 800 series legends. These additional markings are disregarded within this manual. They ...

  • Page 11

    Wiring connections page 19 page 18 wiring connections keypad jumper options keypad numbering (ident) all keypads must have the ident jumper in position in order that the system can recognise the keypad it is communicating with. This information is written to the log as the system is set and unset. I...

  • Page 12

    Wiring connections page 21 page 20 wiring connections ace receiver wiring & jumper options ace is also available as a stand alone receiver. The wiring for the receiver is the same as for the rkp(s) with the exception that the speaker wiring terminal on the ace is marked as sp- and not spkr. The ace ...

  • Page 13

    Wiring connections page 23 page 22 wiring connections batt + & - factory fitted sealed lead acid battery connections. The gardtec 840 is suitable for the installation of all the popular sizes of alarm batteries. Suggested sizes would be:- 12v 1.2ah suitable only for the smallest installations. 12v 2...

  • Page 14

    Zone keyswitch option up to eight zones may be allocated as zone keyswitches. This option is carried out via the ‘program zone type’ option. Either normal or biased keyswitches may be used and the correct option for the keyswitch you are using should be chosen during programming. Wiring for the keys...

  • Page 15

    Page 27 fig. 16 prodigi or gardtec 840 modem wiring. Note: modem will give 8 channels and leave d1, d2 & d3 (pa term) free for other uses for a prodigi program digicom type to gardiner for modem mod+ff or mod+pid remove link from 12v & line fault terminals before connecting prodigi/modem both the pr...

  • Page 16

    Page 29 rkp 12v this terminal provides the +12v supply for the keypads and ace units (see keypad wiring for more detail). A maximum current draw of 0.5amp* 1 is available from this terminal. Rkp 0v this terminal is the 0v supply for the keypads and ace units (see keypad wiring for more detail). Clk ...

  • Page 17

    Page 31 fig. 20 traditional bell box wiring. Fig. 21 novagard wiring fig. 22a novagard x wiring note: terminal positions changed for clarity strobe + - bell + - bell hold- sab tmp n/c microswitch siren/bell strobe light gardtec 800 series strobe + - bell + - bell hold- sab tmp gardtec 800 series + -...

  • Page 18

    Page 33 fig. 23 typical 4 wire configuration + - 12v + - az1 + - tz1 + - az2 + - tz2 + - az3 + - tz3 + - az4 + - tz4 + - az5 + - tz5 + - az6 + - tz6 + - az7 + - tz7 + - az8 + - tz8 alarm zone 1 + loop tamper zone 1 - loop alarm zone 2 + loop tamper zone 2 - loop alarm zone 3 + loop tamper zone 3 - l...

  • Page 19

    Page 35 fig. 24 typical 2 wire configuration + - 12v + - az1 + - tz1 + - az2 + - tz2 + - az3 + - tz3 + - az4 + - tz4 + - az5 + - tz5 + - az6 + - tz6 + - az7 + - tz7 + - az8 + - tz8 alarm zone 1 + loop alarm zone 9 - loop alarm zone 2 + loop alarm zone 10 - loop alarm zone 3 + loop alarm zone 11 - lo...

  • Page 20

    Page 37 fig. 25 typical 2 wire eol configuration + - 12v + - az1 + - tz1 + - az2 + - tz2 + - az3 + - tz3 + - az4 + - tz4 + - az5 + - tz5 + - az6 + - tz6 + - az7 + - tz7 + - az8 + - tz8 alarm zone 1 + loop alarm zone 9 - loop alarm zone 2 + loop alarm zone 10 - loop alarm zone 3 + loop alarm zone 11 ...

  • Page 21

    Page 39 zone expander cards two types of zone expander cards are available, the gardtec 816 expander card that may only be used on the 816 and the gardtec 840 expander that may be used on the 816/840. Up to eight zone expander cards may be fitted to the gardtec 840 and two on the 816 control panel. ...

  • Page 22

    Fig. 31a gardtec 840 zone expanders remote from panel (inc cable colours) red black yellow blue fig. 31b gardtec 816 zone expanders remote from panel (inc cable colours) note: two zone expander cables required. Red black yellow blue red black yellow blue note: in all above examples max cable run is ...

  • Page 23

    Page 43 page 42 expander card 2 (jumper in position 2 840 only) 4 wire mode 2 wire mode 2 wire eol mode aze1 zone 31 zone 31 zone 31 aze2 zone 32 zone 32 zone 32 aze3 zone 33 zone 33 zone 33 aze4 zone 34 zone 34 zone 34 tze1 tamper zone 31 zone 35 zone 35 tze2 tamper zone 32 zone 36 zone 36 tze3 tam...

  • Page 24

    Page 45 page 44 expander card 8 (jumper in position 8 840 only) 4 wire mode 2 wire mode 2 wire eol mode aze1 zone 91 zone 91 zone 91 aze2 zone 92 zone 92 zone 92 aze3 zone 93 zone 93 zone 93 aze4 zone 94 zone 94 zone 94 tze1 tamper zone 91 zone 95 zone 95 tze2 tamper zone 92 zone 96 zone 96 tze3 tam...

  • Page 25

    Page 47 page 46 id expanders the gardtec 840 id expander card allows thirty detectors to be fitted on a four wire run using industry standard id biscuits or id compatible devices. Two id expander cards can be fitted to the control panel. The control panel zones may still be pro- grammed as 'normal (...

  • Page 26

    Page 49 page 48 printer connection the gardtec 816/840 has an rs232 port that may be connected to a standard serial printer, to facilitate this two printer leads are available from gardiner technology. Printer cable no. 1 part no 01-091 connects from pcb direct to printer printer cable no. 2a part n...

  • Page 27: & Z

    Page 51 page 50 gardtec 800 series fig. 35 typical area layout area 3 stores area 1 sales office area 2 distribution common area corridor & reception zones situated in area1:- zone 1 zone 2 zones situated in area2:- zone 3 zone 4 zones situated in area3:- zone 5 zone 6 zones situated in common area:...

  • Page 28

    Page 53 page 52 zone type terminology each zone has a default type that may be re-programmed. Below is an explanation of the terminology used for zone types. 12 hour zone active when control panel is set. Access will allow to pass through on exit. Will allow to pass through on entry only if e/e is o...

  • Page 29

    Page 55 page 54 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 1 relay mode bell (00) as expander mode (option 83) 2 timer1 turn on time (hrs) 00 hours (00) 00 - 23 hours 3 timer1 turn on time (min) 00 minutes (00) 00 - 59 minutes...

  • Page 30

    Page 57 page 56 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 23 no. Of bell arms 99 activations (99) 00 - 99 activations note: if this option is programmed to 0 the bell will not activate 24 [area1] bell ring time 20 minutes (20...

  • Page 31

    Page 59 page 58 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 45 internal sounder mode constant (00) (00) constant (01) timed note: the term internal sounder refers to the speaker output 46 [area1] alarm reset master code (01) (0...

  • Page 32

    Page 61 page 60 *1note: with lcd this option will appear the same as option 51 *2note: with lcd chime is via the part/test/chime option 52. Gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 65 digi test mode once in test mode with lc...

  • Page 33

    Page 63 page 62 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 84 timer 2 turn on time (hrs) 00 hours (00) 00 - 23 hrs gardtec 800 series programming option no/ description default gardtec 800 series programming guide available op...

  • Page 34

    Page 65 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 97 view event log whilst viewing no key to view previous event yes key for next event whilst viewing with lcd press 5 to show user number instead of name whilst viewing with l...

  • Page 35

    Page 67 page 66 gardtec 800 series programming option no/ description default gardtec 800 series programming guide available options 122 area 2 part 3 exit time 30 seconds (30) 0 - 99 seconds 123 area 3 full set exit time 30 seconds (30) 0 - 99 seconds 124 area 3 part 1 exit time 30 seconds (30) 0 -...

  • Page 36

    Page 69 page 68 program orders as previously mentioned an alternative to entering option numbers with an lcd keypad is to scroll through the programmable options using the yes and no keys. To do this enter the engineer code followed by yes, the display will show:- pressing the no key will move to th...

  • Page 37

    Page 71 page 70 headers & options custom screens status display custom display custom text headers & options event log view event log print event log gardtec 800 series programming headers & options digicom type or test start delay channels digicom functions (digigard / prodigi /modem) line fault mo...

  • Page 38: & R

    Page 73 page 72 gardtec 800 series specification & records number of keypads 4 normal or 8 using multi option ace compatible yes onboard relay rating 24v 1a s.P.C.O zone descriptors 16 characters (last 3 omitted with tamper) max no of users 7 + engineer default codes all eng 1234 user 5678 47 + engi...

  • Page 39

    Page 75 page 74 gardtec 800 series specification & records zone no. Descriptor area(s) loop ohm v @ sensor part info 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 91 92 gardtec 800 series specification & records...

  • Page 40

    Page 77 page 76 8 m iscellaneous resetting to factory defaults when resetting the gardtec 800 series to factory defaults several levels of resetting are available, these are:- a) pressing 1, 9, yes, no during initial power up will revert the master code and engineer code (not locked engineer code) b...

  • Page 41

    Page 79 page 78 gardtec 800 series miscellaneous appendix 1 using point id the prodigi communicator or gardtec 800 series modem from gardiner technology may, if required be used to allow point id communication with the gardtec 840. When used in this mode the prodigi/modem will use the ademco point i...

  • Page 42

    Page 81 page 80 gardtec 800 series engineer code entered new log event of engineer code entered has been added to all models. Digi functions programming with point id all normal digi functions should be programmed as usual with the exception of the following items that have no function with point id...

  • Page 43

    Gardiner technology ltd queensway, rochdale, ol11 1tq. United kingdom tel: 01706 510000 fax: 01706 510100 international tel: + 44 1706 510000 fax: + 44 1706 510100 internet: http://www.Gardiner-technology.Com e-mail: sales@gardiner-technology.Com technical support: 01706 510200 technical support fax...