CALIBRATION
Bi-Weekly Calibration:
Tools: Digital Pyrometer with Surface Probe
Warning:PERSONALINJURYFROMBURNSMAYRESULT
WHENCOMINGINCONTACTWITHHOTCOOKING
SURFACES.
NOTE:Calibrationofgrillsisdonewithreleasematerial
sheetsinstalled.
NOTE:CALIBRATIONREQUIREMENTS
Thecontrolsoftwarewillbeeptotheuserwhenitis
appropriatetocalibrate.Thecontrolwillallowcalibration
providedthefollowingconditionsaremet:
• Temperatureiscurrentlyfallingfromadetectedpeak
of360°Forhigher.
• Temperatureisfallingandhasfallen2°Ffroma
detectedpeakthatiswithinthe350-360°Frange.(i.e.
calibrationwouldbeallowedat355°Fiftheachieved
peaktemperaturewas357°F)
• Temperatureisrisingthroughthe350-360°Frangeasa
resultofaheatonpulseoflessthan30seconds.
ToCalibrate:
1. The upper platens and lower grill plate should be at
operating temperatures to perform this calibration
procedure.
Turn on the Master Switch and press to enter cooking
mode.
2. Press or to select a “CLAM” operation and allow
the grill to reach the set temperature and stabilize,
(approximately 30 minutes).
3. Press and hold for three, (3) seconds. “ENTER CODE” is
displayed.
4. Using the Product buttons, 0-9 enter the code, (1251).
“ENTER CODE **** ” is displayed.
5. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” is displayed.
6. Press three, (3) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
7. Press four, (4) times. “PROBE CAL – UPPER XXXF” is
displayed.
8. Place the surface probe of the digital pyrometer directly
on the probe location, (see diagram on following page).
9. Allow at least 5 seconds for the pyrometer to respond
and stabilize. Note the temperature on the pyrometer.
10. If the temperature on the grill control display does not
match the temperature on the pyrometer, adjust the
temperature on the grill control accordingly using the
and buttons.
11. Press . “PROBE CAL – GRILL XXXF” is displayed.
12. Repeat steps 8 - 10.
13. Press to save the changes.
14. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”
15. Press again to exit.
16. Repeat steps 1 - 15 at each control.